Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹4.0 L+₹56,490 (16.5%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹4.7 L+₹1.3 L (37.5%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
14 Jun 2024, 6:00 pmClosed
AGE (I) Kanasar
Asst Garrison Engineer(I) Kanasar Military Station Kanasar, Bikaner (rajasthan)
Repair/Maintenance of summer appliances ie Water Cooler, Desert Cooler, AC, Refrigerator and Deep Freezers at Military Station Kanasar
2024_MES_654607_1
CA NO. AGE(I) KNS/Token No. 02/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Kanasar
Contractor shall be enlisted with MES in Class E and above and category b(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in Work Load Return (WLR) of any other report circulated by competent enginee
8 documents required · 8 mandatory
₹500
ASSISTANT GARRISON ENGINEER (I) KANASAR
₹10,000
26 Jun 2024
17 May 2024
17 Jun 2024
17 May 2024
14 Jun 2024
31 May 2024
24 May 2024 - 31 May 2024
Amount
Dismantling/ removing the defective unserviceble compressor of any capacity for window type, split type, refrigerators, water coolers, Deep freezers etc complete all as specified & directed by Engineer-in-charge.
Supply install test & commissioning new compressor of water cooler capacity 40/80 litres duly charged with fresh mafron gas etc, complete all as specified & directed by Engineer-in-charge. Make :- Voltas / Shriram / Tecumseh / Kirloskar as per existing make at site. Note :- Gurantee card with purchase voucher of original manufacturer shall be produced before payment.
Ditto all as per Item No. 2.00 hereinbefore, but for 150/150litre capacity water cooler complete all as specified & directed by Engineer-in-charge.
Ditto all as per Item No. 2.00 hereinbefore, but for split type AC 2 Ton capacity complete all as specified & directed by Engineer-in-charge.
Ditto all as per Item No. 2.00 hereinbefore, but for split type AC 1.5 Ton capacity complete all as specified & directed by Engineer-in-charge.
Ditto all as per Item No. 2.00 hereinbefore, but for refrigerator 310 litre capacity complete all as specified & directed by Engineer-in-charge.
Ditto all as per Item No. 2.00 hereinbefore, but for Deep Freezer 300 litre capacity complete all as specified & directed by Engineer-in-charge.
M&L for detecting the gas leakage, rectfying the defects vacumizing and charging fresh Gas & commssioning and testing the window/ Split type Air conditioner unit 1.5/2.0 Ton capacity, complete all as specified & directed by Engineer-in-charge.
Dittto all as per Item No.7.00 hereinbefore, but of 310 litre capacity refrigerator complete all as specified & directed by Engineer-in-charge.
Dittto all as per Item No.7.00 hereinbefore, but of water cooler of any capacity complete all as specified & directed by Engineer-in-charge.
Dittto all as per Item No.7.00 hereinbefore, but of deep freezer of any capacity complete all as specified & directed by Engineer-in-charge.
Removing of existing window /split type AC 1.5 / 2.0 ton capacity mounting, cleaning of evaporator and condenser with alkaline based solution, washing of AC , oiling of fan motor and refixing on mounting, including provision for making opening air tight and dust proof including testing and commissioning, complete all as specified & directed by Engineer-in-charge.
M & L for rewinding of electric motor blower fan motor of 1.5/2.0 ton window/ split type AC 1400 RPM 220 V 50 C/S with supper enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load complete all as specified & directed by Engineer-in-charge.
Supply and fix in replacement remote control complete for split type ACs 1.5 to 2 ton capacity complete all as specified & directed by Engineer-in-charge.
Supply and fix in replacement Plastic filter for window type AC 1.5 ton capacity complete all as specified & directed by Engineer-in-charge.
Supply and fix in replacement Plastic filter for window type AC 1.5 ton capacity complete all as specified & directed by Engineer-in-charge.
Supply and fix in replacement Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Window type Air Conditioner complete all as specified & directed by Engineer-in-charge. (Make:- AUE / USHA/ LG/Voltas)
Supply and fix in replacement Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5/2.0 TR Split type Air Conditioner complete all as specified & directed by Engineer-in-charge. (Make:- AUE / USHA/LG/Voltas)
Supply and fix in replacement Thermostatic switch with knob suitable for window type AC 1.5 TR complete all as specified and directed. (Make:- INDFOS / RENUTRAL )
Supply and fix in replacement fan blade suitable for out door unit of Split type AC capacity 1.5/2.0 complete all as specified and directed. Make:-Carrier/voltas/LG
Supply and fix in replacement blower complete with fins suitable for in door unit of Split type AC capacity 1.5/2.0 complete all as specified & directed by Engineer-in-charge. Make:- Carrier/voltas/LG/Bluestar
Supply & fix in replacement of copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length including insulating piping complete all as specified & directed by Engineer-in-charge.
Supply and fix in replacement only Running capacitor 45 to 50 MFD 230 volts, 50 Hz for window/split AC complete all as specified & directed by Engineer-in-charge. Make:- Tibcon/ Sharda / Epcos/ Usha
Supply and fix in replacement only Starting capacitor 100 to 120 MFD 230 volts, 50 Hz for window/split Ac all as specified and directed by Engineer-in-Charge. Make:- Tibcon/ Sharda / Epcos/ Usha
Taking down carefully the follwing parts from the existing AC in lieu providing new accessories / parts as per existing as under:-
Contactor for split AC (1.5 / 2.0 TR) complete all as specified & directed by Engineer-in-charge.
PCB for split AC (1.5 / 2.0 TR) complete all as specified & directed by Engineer-in-charge.
Starting relay for split AC (1.5 / 2.0 TR) complete all as specified & directed by Engineer-in-charge.
Supply and fix in replacement only Over Load Protector (OLP) suitable air conditioner 1.5 TR/ 2.0 TR capacity complete all as specified & directed by Engineer-in-charge. Make : SRIRAM / Ranutrol/ Indfoss
Taking down carefully the following accessories/ parts from existing water coolers and in lieu providing new accessories / parts in theses water coolers as per details given here in after :-
Filter copper complete all as specified & directed by Engineer-in-charge.
Capillary Tube of copper existing size as per sample complete all as specified & directed by Engineer-in-charge.
PVC water outlet pipe 15mm dia including clamps complete all as specified & directed by Engineer-in-charge.
Drain pipe of same quality , length and dia as per existing complete all as specified & directed by Engineer-in-charge.
S&F new condenser size 12''x12''/12''x15'' complete all as specified & directed by Engineer-in-charge.
Taking down defective fan motor from water coolers, dismantling the old burnt winding from the motor nad rewinding with super enamelled copper wire as per existing size Make:- Milan / Chetak, including replacement of shaft, bushes mounting rubbers, nuts bolts and refixing after reassembling and testing in existing water coolers for under mentioned fan motors (Note:- The unit quoted rate shall be deemed to be included replacment of minor apres such as rubber, nuts washers insulating materials and clamps)
Fan motor of capacity 1/10 HP 230Volts, Single Phase, complete all as specified & directed by Engineer-in-charge.
Fan motor of capacity 1/35 HP 230Volts, Single Phase, complete all as specified & directed by Engineer-in-charge.
Taking down carefully fan motor from existing water coolers and in lieu providing new fan motor 1/10 HP 230 Volts, 50 HZ including replacement of mounting legs complete all as specified & directed. Make of Fan motor:- Frac Master / Polor/Usha
Supply & Fix in repalcement push cock ( stainless steel) for water cooler as per sample complete all as specified and directed.
Supply & fixing in replacement thermostat for water cooler complete as specified and directed. Make: Indfoss/Denfoss
Supply and fix in replacement Starting capacitor 60 to 80 MFD 230 volts, 50 Hz for water cooler. Make : KELTRON / USHA / Tibcon
Supply and fix in replacement Flexible Core PVC insulated with stranded copper conductor 40 / 0.0076 Sqmm 3 core 600/1100 V ISI Marked complete all as specified & directed by Engineer-in-charge. Make : Finolex/Havells/Plaza
Supply and fix in replacement 20mm bore float valve PVC for water coolers as per sample complete all as specified & directed by Engineer-in-charge.
Taking down carefully the following accessories / parts from exisiting refrigeration of any make of capacity 310 litres supply & fixing accessories / parts as per existing in the same refrigeratiors as under :-
Evaporator for 310 litre refrigertors of any make complete all as specified & directed by Engineer-in-charge.
Filter copper of any make complete all as specified & directed by Engineer-in-charge.
Capillary tubes of copper exisitng sizes as per sample complete all as specified & directed by Engineer-in-charge.
Supply & Fix thermostat for refrigerator 310 litre capacity complete all as specified & directed by Engineer-in-charge. Make: Indfoss
Supply & Fix relay for refrigerator 310 litre capacity as per sample complete all as specified & directed by Engineer-in-charge.
M&L for painting of water cooler of capacity 40/80 Ltr external body with one coat of synthetic enameled gray paint complete with spray painting after proper dusting, cleaning and scrapping old painted surfaces including writing SM/MES No complete all as directed by the Engineer-in-Charge.
M&L for painting of desert cooler’s external body, fan & pump with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with spray painting after proper dusting, cleaning and scrapping old painted surfaces complete all as directed by the Engineer-in-Charge.
Supply only Submerssible pump 1.65 mtr head , 18 watt, 230 volts, 50 Hz with for Desert coolers including taking down old one complete all as specified & directed by Engineer-in-charge. Make :- KHAITAN / SUMMER KING/Shakti
Supply and fix in replacement Fan motor kit 1/6 to 1/8 HP 230 Volts 50 Hz for Desert cooler including replacement of mounting legs complete all as specified & directed by Engineer-in-charge. Make :- KHAITAN / SUMMER KING/Shakti
Taking down carefully fan motor 1/6 to 1/8HP 230volts, 50Hz from exisiting desert coolers and refixing the same fan motor after rewinding with super enamelled copper wire of existing size complete including replacement of mounting legs complete all as specified & directed by Engineer-in-charge.
Suuply & Fix including taking down capacitor for desert cooler 4MFD 230 volts complete all as specified & directed by Engineer-in-charge. Make:- Asian / Tibcon/ Usha/ Universal
Supply & Fix including taking down front grill including nuts & bolts and wsahers suitable for 18/20" sweep desert coolers complete all as specified & directed by Engineer-in-charge.
Supply and fix including taking down wooden shelving pad for Desert cooler each set weighting not less than 500 grams (Set of three) complete all as specified & directed by Engineer-in-charge.
Supply & Fix including taking down supporting jali for desert coolers (set of three ) complete all as specified & directed by Engineer-in-charge.
Supply & Fix including taking down fan blades mode of aluminium for desert cooler all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Side Panels/filter panels made of galvanized iron Sheet 0.67 mm thick for 4000 cum/Hr Desert Cooler all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement fan motor fixing kit/ assembly made of flat iron and clamps including required size of nuts and bolts suitable for metal body desert coolers of capacity 4000 Cum/Hour complete all as specified and directed by Engineer -in - Charge.
Supply and fix in replacement PVC flexible pipe (from vertical pump to distributer and distributer to panel) 15mm dia for Desert cooler including 3 way distributor junction tee set complete.
Supply and fix in replacement Desert Cooler Fan regulator for 4000 to 5000 cum/Hr Desert Cooler capacity of various makes all as per existing one all as specified and directed by Engr-in-charge Make:- KHAITAN / SUMMER KING/Shakti
Supply and fix in replacement Switch Piano 5 Amp single pole 230 volt. Make :- Anchor/kinjal/plaza/Cona/SSK/Leader
Supply only PVC Lead wire 1.5 sqmm stranded copper conductor 1.5 sqmm 3 core ISI Marked all as specified and directed. Make:- Finolex, Havells
S & F Plug top for desert cooler 3 pin 5 Amps, 230 Volt AC, ISI marked complete all as specified and directed. Make:- Anchor / Plaza
S & F Plug top for desert cooler 5 pin 15/16 Amps, 230 Volt AC, ISI marked complete all as specified and directed. Make:- Anchor / Plaza
S&F of U/S single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 25 Amps MCB, 240 volt complete all as spacified and directed. Make:- Havells/L&T/HPL
S&F in repair switch piano, flush type, single pole, one way, 15/16 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F in repair socket outlet universal type, 6 pin, 15/16 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
V.K. Infra Engineering
Bhavya Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .