Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-Finance | ₹21.0 L | L1 | Accepted-Finance Accept |
| 2 | L2₹21.7 L+₹68,735.98 (3.27%)Accepted-Finance | ₹21.7 L+₹68,735.98 (3.27%) | L2 | Accepted-Finance Accept |
| 3 | L3₹21.8 L+₹75,675.28 (3.60%)Accepted-Finance | ₹21.8 L+₹75,675.28 (3.60%) | L3 | Accepted-Finance Accept |
| Sl No | Description | Qty | Unit | OMEX CONTROL SYSTEM L3 | Tanna Electric Company L1 | CHAITRA ELECTRICALS AND ENGINEERING L2 |
|---|---|---|---|---|---|---|
| 1.00Power Upgradation and allied works in LTMG Hospital | ||||||
| 1.01 | Electrical safety audit of Hospital building | 10,530 | sqmtr | 73 ₹7,68,690 | 69.62 ₹7,33,098.6 Lowest | 72.45 ₹7,62,898.5 |
| 1.02 | Electrical safety audit of college building | 6,800 | sqmtr | 73 ₹4,96,400 | 69.62 ₹4,73,416 Lowest | 72.45 ₹4,92,660 |
| 1.03 | Laying of cables upto 400 sq mm | 45 | mtr | 91 ₹4,095 Lowest | 91.5 ₹4,117.5 | 94 ₹4,230 |
| 1.04 | S/M end termination for 3.5x300 cable | 2 | set | 1,579 ₹3,158 | 1,542.6 ₹3,085.2 Lowest | 1,577 ₹3,154 |
| 1.05 | S/I of 12 way SPN DB | 1 | no | 6,112 ₹6,112 | 5,952 ₹5,952 Lowest | 6,085 ₹6,085 |
| 1.06 | S/I of 40 Amp 100 mA DP ELCB | 1 | no | 4,878 ₹4,878 | 4,858.62 ₹4,858.62 Lowest | 4,968 ₹4,968 |
| 1.07 | S/I of 125 Amp TPN MCB | 9 | no | 17,015 ₹1,53,135 | 16,990.75 ₹1,52,916.75 Lowest | 17,373 ₹1,56,357 |
| 1.08 | S/I of SMCJB junction box 320x220x65 mm | 9 | no | 2,451 ₹22,059 | 2,427.8 ₹21,850.2 Lowest | 2,482 ₹22,338 |
| 1.09 | S/I of Indoor LED fixture 45 watts | 14 | no | 5,521 ₹77,294 | 5,396.7 ₹75,553.8 Lowest | 5,518 ₹77,252 |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
22 Aug 2026, 4:00 pmClosed
AE MnE
AE MnE LTMG Hospital Sion
LTH/275A/R
2026_MCGM_1327938_1
LTH/275A/R
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
Dean LTMG Hospital
As per mentioned in tender condition
3 documents required · 3 mandatory
₹4,712
₹25,000
11 Sept 2026
15 Aug 2026
24 Aug 2026
15 Aug 2026
22 Aug 2026
15 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Power Upgradation and allied works in LTMG Hospital | |||||
| 1.01 | Electrical safety audit of Hospital building | - | sqmtr | - | - |
| 1.02 | Electrical safety audit of college building | - | sqmtr | - | - |
| 1.03 | Laying of cables upto 400 sq mm | - | mtr | - | - |
| 1.04 | S/M end termination for 3.5x300 cable | - | set | - | - |
| 1.05 | S/I of 12 way SPN DB | - | no | - | - |
| 1.06 | S/I of 40 Amp 100 mA DP ELCB | - | no | - | - |
| 1.07 | S/I of 125 Amp TPN MCB | - | no | - | - |
| 1.08 | S/I of SMCJB junction box 320x220x65 mm | - | no | - | - |
| 1.09 | S/I of Indoor LED fixture 45 watts | - | no | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
headerdata.pdf
Other Document • 0.38 MB
scopeofwork.pdf
Tender Documents • 0.40 MB
SBD.pdf
Additional Documents • 1.51 MB
BOQ_2274643.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .