Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.0 CrAccepted-AOC | ₹9.0 Cr Quoted ₹9.8 Cr | L-1 | Accepted-AOC Bidder is L-1 in Part A and B |
| Sl No | Description | Qty | Unit | ADITEL COMMUNICATIONS L1 |
|---|---|---|---|---|
| 1.00Telecom system (SUPPLY) | ||||
| 2.00 | Supply of MPLS TP equipment | 2 | nos | 19,87,000 ₹39,74,000 Lowest |
| 3.00 | Supply of IP/MPLS type switch | 1 | no | 3,17,000 ₹3,17,000 Lowest |
| 4.00Supply of converter | ||||
| 5.00 | AC-DC (230 V AC to 48 V DC) | 4 | nos | 34,000 ₹1,36,000 Lowest |
| 6.00 | AC-DC (230 V AC to 24 V DC) | 4 | nos | 45,700 ₹1,82,800 Lowest |
| 7.00 | DC-DC (48 V DC to 24 V DC) | 18 | nos | 65,900 ₹11,86,200 Lowest |
| 8.00 | DC-DC (24 V DC to 48 V DC) | 2 | nos | 39,500 ₹79,000 Lowest |
| 9.00 | Supply of battery charger with battery backup | 2 | nos | 56,600 ₹1,13,200 Lowest |
| 10.00 | Supply of porta cabin | 4 | nos | 2,89,654 ₹11,58,616 Lowest |
Tender Value
Refer Docs
EMD Value
₹19.7 L
Closing Date
20 Aug 2025, 2:00 pmClosed
SANDIP SUNDAR SAHOO, MGR
GAIL INDIA LTD., SECTOR-1 , NOIDA
SUPPLY INSTALLATION OF TELECOM SCADA EQUIPMENT FOR EXTENDING DATA CONNECTIVITY TO UPCOMING CGD HOOKUPS LMC CONNECTIVITY IN EASTERN WESTERN REGION ON ARC BASIS
2025_GAIL_241998_1
GAIL/NOIDA/CnP/PROJ/ARC/25-23
Open Tender
Oil/Gas
Works
730 days
AS PER TENDER
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹19.7 L
Yes
THROUGH VC
23 Dec 2025
22 Jul 2025
21 Aug 2025
22 Jul 2025
20 Aug 2025
30 Jul 2025
29 Jul 2025
Amount
Telecom system (SUPPLY)
Supply of MPLS TP equipment
Supply of IP/MPLS type switch
Supply of converter
AC-DC (230 V AC to 48 V DC)
AC-DC (230 V AC to 24 V DC)
DC-DC (48 V DC to 24 V DC)
DC-DC (24 V DC to 48 V DC)
Supply of battery charger with battery backup
Supply of porta cabin
Supply of LCT
Supply of equipment racks
Supply of solar panel with battery back up 300 W
Supply of solar panel with battery back up 200 W
Supply of solar panel with battery back up 50 W
Supply of explosion proof telephone
Supply of weatherproof telephone
Supply of acoustic half hood booth
Supply of multi-paired armoured cable (10 pair)
Supply of 6 Twisted Pair, 1.5 Sq. mm ( 12 Core ), Individual Pair andOverall Aluminium Mylar Tape Shielded with drain wire
Supply of 6 Twisted Pair, 0.50 Sq. mm ( 12 Core ) Individual Pair and Overall Aluminium Mylar Tape Shielded with drain wire
Supply of Telemetry Interface Cabinet (TIC)
Supply of analog phones
Supply of FXO Gateway
Supply of FXS Gateway
Supply of Ethernet switch
Supply of RTU
Supply of mini RTU
Supply of FTC
Supply of joint closures
Supply of IP camera
Supply of spares for telecom
Supply of spares for RTU
Supply of ethernet to serial converter
Supply of optical to serial convereter
Supply of RS 232 to RS 422/RS485 converter
Supply of Optical to Ethernet Converter
Supply of Out door equipment panel
Supply of Field Mounted enclosure conforming IP-66
Supply of GPRS Modem
Supply of ATEX switch 8 port
Supply of 24F OFC cable
Supply of RTU management licenses for makes like Husky, Schneider, etc
Telecom system (WORKS)
Installation of MPLS/TP equipment
Integration of MPLS/TP equipment with existing NMS
Installation and commissioning of solar system
Installation of porta cabin
Laying and termination of multi-paired armoured cable (10 pair)
Installation and configuration of converter/switch and interfacing of same with flow computer and integration with SCADA system
Installation of TIC Panel
Design, engineering and submission of documents
Testing of OFC and submission of reports
Earthing works
Installation testing & commissioning of Instrumentation Cable
Installation commissioning and integration of RTUs in existing SCADA Server
Installation commissioning and integration of mini RTUs in existing SCADA Server
Installation and integration of IP cameras in existing server for each cameras
Installation of GPRS Modems if supplied as Free Issue
Extending of leased lines for 1000 km distance including modems (one ethernet interface & one E1 interface for LAN) at both ends
Rectification of OFC including supply of joint pit with identification of fault and testing of OF cable
Installation of outdoor panel
Transportation charges for Free Issue Material (per Km rate to be quoted)
Laying of OFC through HDD method
Laying of OFC through direct trench method
Point to Point Radio communication (2.4/5.8 GHz licence free ISM band)
Laying of OFC Cable ( if OFC supplied as free issue by GAIL)
Blowing of OFC in duct
Manday Charges
Total amount excluding GST for Part-A
GST (CGST&SGST/UTGST or IGST) in percentage (%) on Net Total Amount
Description of Work / Item(s)
Amount
Telecom system (SUPPLY)
Supply of MPLS TP equipment
Supply of IP/MPLS type switch
Supply of converter
AC-DC (230 V AC to 48 V DC)
AC-DC (230 V AC to 24 V DC)
DC-DC (48 V DC to 24 V DC)
DC-DC (24 V DC to 48 V DC)
Supply of battery charger with battery backup
Supply of porta cabin
Supply of LCT
Supply of equipment racks
Supply of solar panel with battery back up 300 W
Supply of solar panel with battery back up 200 W
Supply of solar panel with battery back up 50 W
Supply of explosion proof telephone
Supply of weatherproof telephone
Supply of acoustic half hood booth
Supply of multi-paired armoured cable (10 pair)
Supply of 6 Twisted Pair, 1.5 Sq. mm ( 12 Core ), Individual Pair andOverall Aluminium Mylar Tape Shielded with drain wire
Supply of 6 Twisted Pair, 0.50 Sq. mm ( 12 Core ) Individual Pair and Overall Aluminium Mylar Tape Shielded with drain wire
Supply of Telemetry Interface Cabinet (TIC)
Supply of analog phones
Supply of FXO Gateway
Supply of FXS Gateway
Supply of Ethernet switch
Supply of RTU
Supply of mini RTU
Supply of FTC
Supply of joint closures
Supply of IP camera
Supply of spares for telecom
Supply of spares for RTU
Supply of ethernet to serial converter
Supply of optical to serial convereter
Supply of RS 232 to RS 422/RS485 converter
Supply of Optical to Ethernet Converter
Supply of Out door equipment panel
Supply of Field Mounted enclosure conforming IP-66
Supply of GPRS Modem
Supply of ATEX switch 8 port
Supply of 24F OFC cable
Supply of RTU management licenses for makes like Husky, Schneider, etc
Telecom system (WORKS)
Installation of MPLS/TP equipment
Integration of MPLS/TP equipment with existing NMS
Installation and commissioning of solar system
Installation of porta cabin
Laying and termination of multi-paired armoured cable (10 pair)
Installation and configuration of converter/switch and interfacing of same with flow computer and integration with SCADA system
Installation of TIC Panel
Design, engineering and submission of documents
Testing of OFC and submission of reports
Earthing works
Installation testing & commissioning of Instrumentation Cable
Installation commissioning and integration of RTUs in existing SCADA Server
Installation commissioning and integration of mini RTUs in existing SCADA Server
Installation and integration of IP cameras in existing server for each cameras
Installation of GPRS Modems if supplied as Free Issue
Extending of leased lines for 1000 km distance including modems (one ethernet interface & one E1 interface for LAN) at both ends
Rectification of OFC including supply of joint pit with identification of fault and testing of OF cable
Installation of outdoor panel
Transportation charges for Free Issue Material (per Km rate to be quoted)
Laying of OFC through HDD method
Laying of OFC through direct trench method
Point to Point Radio communication (2.4/5.8 GHz licence free ISM band)
Laying of OFC Cable ( if OFC supplied as free issue by GAIL)
Blowing of OFC in duct
Manday Charges
Total amount excluding GST for Part-B
GST (CGST&SGST/UTGST or IGST) in percentage (%) on Net Total Amount
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 9.24 MB
BOQ.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .