AC ELECT SHQ BSF SHILLONG
SHQ BSF SHILLONG
C/O SARV DHARM STHAL GARRAGE AND POL STORE ELECTRIC SUB STATION PUMP ROOM AND GENERATOR SHED 02 NOS CENTRAL MORCHA 04 NOS CORNER BUNKERS 02 NOS O2 MEN BUNKERS AND SENTRY POST AT BOP BARMANBARI OF 11 BN SHQ BSF SHILLONG FTR SH ELECTRICAL WORKS
2021_BSF_634382_1
dig/shq engg(e)/2021-22/23
Open Tender
Electrical Works
Item Rate
180 days
SHQ BSF SHG
As per Tender docoments
8 documents required · 8 mandatory
₹0
₹9,906
Yes
23 Jun 2021
17 Jun 2021
23 Jun 2021
17 Jun 2021
22 Jun 2021
17 Jun 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in recessed PVC conduit, with modular type switch, suitable modular plate, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.(Group B)
Wiring for circuit/ submain wiring alongwith earh wire with the 2X1.5 Sqmm +1X1.5 Sqmm size of FR PVC insulated copper conductor, single core cable in recessed PVC conduit as required.
Wiring for power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess i/c P/F 6 pin 5/6 & 15/16 amp modular socket out let and 15/16 amp modular switch, connection etc as reqd. (for power plug)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess i/c P/F 3 pin 5/6 amp modular socket out let and 5/6 amp modular switch, connection etc as reqd. (for light plugs to be used in non resdl bldgs)
Supplying and fixing 2+8 way, double door single pole and neutral, sheet steel, MCB distribution board, 230 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator)
Supplying and fixing 2+4 way, double door single pole and neutral, sheet steel, MCB distribution board, 230 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator)
S/F following rating double pole 240 Volts isolator in the existing MCB DB complete with connections, testing and commissioing. 63 Amp
S/F following rating double pole 240 Volts isolator in the existing MCB DB complete with connections, testing and commissioing. 40 Amp
Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.
Earthing with G.I. earth pipe 4.5 mtr long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.
Providing and laying of earth electrode with 6 SWG GI direct in 0.5 mtr below the ground level for the earth connection.
Providing and fixing of lightning finial made of 25 mm dia 300 mm long G.I. tube having single prongat top with 85 mm dia 6 mm thick G.I. base plate i/c holes etc. complete as req.
Providing and fixing testing joint made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 Nos of G.I. bolts,nuts,chuck nuts and spring washers etc.complete as req.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall/GI pipe for lighting conductor complete as required. (For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall/GI pipe for lighting conductor complete as required. (For vertical run)
Supplying and laying of following size of 1.1 KV Grade PVC insulated PVC sheathed power cable of grade 1.1 KV armoured XLPE power cable of 2X25 Sqmm aluminium i/c excavation and reffiling the trench but excluding sand cushioing and protective covering etc as reqd.
Supplying and laying of following size of 1.1 KV Grade PVC insulated PVC sheathed power cable of grade 1.1 KV armoured XLPE power cable of 3.5X35 Sqmm aluminium i/c excavation and reffiling the trench but excluding sand cushioing and protective covering etc as reqd.
Supplying and laying of following size of 1.1 KV Grade PVC insulated PVC sheathed power cable of grade 1.1 KV armoured XLPE power cable of 3.5X120 Sqmm aluminium i/c excavation and reffiling the trench but excluding sand cushioing and protective covering etc as reqd.
Supplying and fixing of 15 W LED full glow pro 1X1 recess/surface square type flat panel with high brightness for glare free homogenious illumination and separate electronic driver, suitable for low depth ceiling i/c all conection complete as required.
SITC of 1200 mm ceiling fan i/c wiring the down rod standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single cable etc as reqd. (Havells/Bajaj/usha or eqvt.)
Supplying and fixing 2 module stepped type electronic fan regulator on the existing modular plate switch box I/C connection as reqd.
SITC 48 Watt LED street light I/P voltage 220V AC, with suitable electronic driver and high power LED as light source , with secondary optics made in pressure die cast housing with toughned glass IP66 protection on existing GI pipe bracket i/c conn etc as reqd.
P/F of 43 mm dia 1.5 Mtr long GI pipe (Med) bracket on the existing wall with suitable MS clamps 2 Nos and nut and bolt for mounting of LED fitting i/c painting and wiring with 2 x 1.5 Sqmm FR PVC insulated copper conductor cable as req.
SITC of exhaust fan 250 mm sweep inbuilt with decorative plastic/ poly carbonate body with ravour shutter complete set in the existing opening i/c conn. As req. ( Havells/Usha or equi.
SITC of prefabricated phophatised powder painted compartmetalized electric meter cum distribution board wall mounted type cubical construction with rubber gaskets etc fabricated with 1.6 sqmm thick MS sheet steel size 750X650X150mm P/F TPN Alu bus bar of capacity 200 Amp and TP MCCB 125 amp 16KA, 63 Amp 03 Nos fixed thermal and fixed magnetic setting (Cat B) as req. with front hinged opneble cover having locking arrangement with suitable ducts for incoming/outdoor cables as req i/c painting, interconnection with 6 sqmm PVC insulated copper conductor wires duly sleeved earthing etc complete with following provisions i/c incoming and outgoing connections of cables and wires thimbles as req.
Pvdg and erection of medium class (duty) 80 mm GI pipe 9 mtr long i/c painting etc in cement concrete 1:3:6 (I cement, 3 coarse sand, 6 stone aggregate 40 mm nominal size) foundation etc as reqd.
M/S MAHAJAN ENTERPRISE SHILLONG
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .