Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC AOC | |
| 2 | L2₹43.7 L+₹3.9 L (9.77%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/s Rohit Construction Co. L1 | BIDAWAT ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by Engineer-in-Charge. | 307.8 | Cum | 120 ₹36,936 | 100 ₹30,780 Lowest |
| 2.00 | Removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed. | 134.52 | Cum | 20 ₹2,690.4 Lowest | 20 ₹2,690.4 Lowest |
| 3.00 | Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed. | 173.28 | Cum | 20 ₹3,465.6 Lowest | 20 ₹3,465.6 Lowest |
| 4.00 | Material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.
Note : Punned thickness shall be measured for payment. | 92.34 | Cum | 100 ₹9,234 Lowest | 100 ₹9,234 Lowest |
| 5.00 | Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed. | 7,600 | Each | 15 ₹1,14,000 Lowest | 15 ₹1,14,000 Lowest |
| 6.00 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 180 | RM | 10 ₹1,800 | 9 ₹1,620 Lowest |
| 7.00 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 300 | RM | 10 ₹3,000 | 9 ₹2,700 Lowest |
| 8.00 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 300 | RM | 10 ₹3,000 | 9 ₹2,700 Lowest |
| 9.00 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 300 | RM | 15 ₹4,500 | 9 ₹2,700 Lowest |
| 10.00 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 220 | RM | 15 ₹3,300 | 9 ₹1,980 Lowest |
Tender Value
₹40.0 L
EMD Value
₹80,000
Closing Date
19 Jun 2026, 6:00 pmClosed
GE AF NAL
GE AF NAL
As mentioned and described in BOQ
2026_MES_768428_1
GE (AF) NAL /T-25/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF NAL
As per NIT and tender documents class D and above and category b(i)
9 documents required · 9 mandatory
₹500
GE AF NAL
₹80,000
Yes
20 Aug 2026
29 May 2026
22 Jun 2026
29 May 2026
19 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by Engineer-in-Charge. | 307.8 | Cum | 10 | ₹3,078 |
| 2 | Removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed. | 134.52 | Cum | 1.25 | ₹168.15 |
| 3 | Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed. | 173.28 | Cum | - | - |
| 4 | Material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.
Note : Punned thickness shall be measured for payment. | 92.34 | Cum | 22 | ₹2,031.48 |
| 5 | Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed. | 7,600 | Each | 22 | ₹1,67,200 |
| 6 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 180 | RM | - | - |
| 7 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 300 | RM | 22 | ₹6,600 |
| 8 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 300 | RM | 22 | ₹6,600 |
| 9 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 300 | RM | 10 | ₹3,000 |
| 10 | Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 Sqmm from trenches complete all as specified and directed.
Note : Excavation and earth work shall be measured and paid for separately under relevant item | 220 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_860552.xls
BOQ • 0.37 MB
Tender25.pdf
Tender Documents • 2.83 MB
Tenderdocumentcorrigendum.pdf
PDF • 0.38 MB
Datecorrigendum.pdf
PDF • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .