Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹37.5 L+₹1.1 L (3.12%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹40.8 L+₹4.5 L (12.3%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L3 | Rejected-Finance Not become lowest bidder |
Tender Value
₹40.8 L
EMD Value
₹81,660
Closing Date
6 Sept 2022, 6:00 pmClosed
Lt Col Deepak Kumar
Garrison Engineer Jhansi
SPL REPAIR FOR REPLACEMENT OF VARIOUS PUMP SETS AND CONNECTED WORKS AGAINST BER AND CERTAIN OTHER SANCTIONED WORKS UNDER AGE E/M AT GE JHANSI
2022_MES_542963_2
GE/JHA/TOK/24 of 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹81,660
Yes
6 Oct 2022
23 Aug 2022
8 Sept 2022
23 Aug 2022
6 Sept 2022
25 Aug 2022
Amount
Supply, installation, testing and commissioning of Horizontal Split Case double stage motor-pump set consist of Mechanical seal pump with cast iron impeller, C-40 Shaft, discharge 50000 GPH at 75 mtr head complete duly coupled with electric driven three phase induction Motor AC 415 volts, 50 Hz, 1450 RPM of capacity 100 HP with coupling type TC 16/17, with and including dismantling of old PCC foundation and making new PCC foundation work, new base frame made out by MS channel, fixing accessories i.e. foundation bolts, grout, shims, lower base plate, flange, nut, washers etc as per manufacturer's design and recommendation, sufficiently substantial to reduce vibrations and rigid enough to avoid any twisting or misalignment, with and including gland coupling & guard, cushy foot anti vibration pad, disconnecting of all pipe lines/electric connections for existing unserviceable pumping set, dismantling / lifting of unserviceable pump set with all accessories from base frame, installing new pump, checking the alignment of pump motor set, reconnecting of all pipe lines, making electrical connections, complete testing and commissioning of pump set, complete all as specified and directed. Note: (a) Any defective component(s) and/or any other materials which is not specified / given in Schedule ‘A’, but essential to be repair/replace, to make pump set fully functional, the cost of the same is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (b) The cost of PCC foundation i.e. earth work, PCC etc suitable for common base frame of 100HP centrifugal pumping set is deemed to be included in quoted. (c) The cost of all kind of T&P, transportation and other necessary equipment shall be arranged / brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor in this effect. Make : Kirloskar (Model No DSM-100/36) or equivalent
Supply, installation, testing and commissioning of borewell submersible pump set suitable for 100mm dia delivery pipe , electric driven with 3 phase, 415 volts, 50 Hz, copper wound submersible electric motor coupled with submersible multistage pump suitable for discharge 1350 LPM at a head of 55m of capacity 25 HP with bronze impeller, CI bowl, SS casing & SS pump and motor shaft complete including disconnecting all electrical and water connections and taking down of existing unserviceable pump set and depositing to MES E/M store yard complete all as specified and directed by Engineer-in-charge.
Supply, installation, testing & commissioning of Granular chlorination(Calcium hypochlorite) dosing pump(MODEL 96 NGQ 51), high pressure, single head, gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U.S. GPD and adjustable high pressure of up to 100 PSI(7KG/CM)2 with accessories including lead , tubing, connecting nuts , ferrules, injection check valve etc. incl Dosing system(MODEL ADS-1)-100 Ltr.FRP tank with lid & level gauge along with agitator and shaft & blade in plastic mounted on tank.Agitator motor with specification-voltage input-230V,Single phase,50Hz,900 RPM. MAKE-DECLIBAC Technologies
S&F in replacement of PVC insulated, Flexible wire , heavy duty industrial electric cable with multi stranded copper conductor of size 50.0 Sqmm, single core , 1100 volts grade, with and incl making all necessary electric connections with and incl thimble / lugs and glands of suitable size at both ends, complete all as specified and directed.
Supply and connecting of 3 core x 10 sqmm Flat copper conductor cable 1100 Volts grade, PVC Insulated & PVC Sheathed conforming to IS- 694/1990 for submersible pump set complete all as specified and directed.
Supply and replace Cast Iron sluice valve of size 300mm dia bore, having pressure rating PN 1.6, double flanged, non-rising stainless steel spindle with iron wheel conforming to IS:14846-2000 with jointing material ie new rubber gasket, nuts & bolts, washer etc of suitable size and taking down old unserviceable sluice valve complete all as specified and directed.
All as per item No. 8.00 here-in-before but of size 200mm dia NB.
All as per item No. 8.00 here-in-before but of size 150mm dia NB.
Supply and replacement Cast Iron Non Return Valve (NRV) 200mm NB with flanged ends swing type / ball type ISI marked including replacement of necessary packing material, bolts, nuts and washers complete all as directed.
All as per item No. 11.00 here-in-before but of size 150mm NB.
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
M&L for takingdown old unserviceable valve pits of any size and constructing of full brick mesonary pits of internal dimensions 1mtr x1mtr x1.2 mtrs (bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:3:6) 15 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The sluice valve and other fittings should be housed in center of the pit. the vertices of the pit should in right angle and champhered .The top cover of the pit will be made out of MS sheet min 2mm thick witth angle iron frame made out of MS angle 50mm x 50 mm x 6 mm with MS hindges two nos, and locking arrangements duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide, complete all as specified and directed.
Taking up old UNSV CI/DI pipe incl all fittings with spigot and socket ends and lead joint of size 100mm bore complete all as specified and directed.
All as per Item No. 15.00 here-in-before but of size 150mm bore.
All as per Item No. 15.00 here-in-before but of size 200mm bore.
Supply, laying and testing of Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint incl jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete of size 100mm bore class K-9 laid in trenches complete all as specified and directed .
All as per Item No. 18.00 here-in-before but of size 150mm bore.
All as per Item No. 18.00 here-in-before but of size 200mm bore.
All as per Item No. 18.00 here-in-before but flanged pipe of size 150mm bore.
S&F in replacement of DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of 100mm bore size with and incl all jointing material complete all as specified and directed. Note:- The rate quoted by contractor deemed to be incl necessary earth works.
All as per item No. 22.00 here-in-before but suitable for pipe of size 150mm dia
All as per item No. 22.00 here-in-before but suitable for pipe of size 200mm dia
Plain cement concrete, type B-2 ( 1 : 2: 4), (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for ductile iron fittings suitable for CI/DI pipe of size 100mm to 400mm bore and any type, class K-12, such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces (single branch, "Y" junction, double branch, cross etc), caps and plugs etc, complete all as specified and directed.
Supply, fabricating and fixing of MS clamp, base frame for pumping set, supports, bracing, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes with and including gasket, nuts & bolts with washers etc, as required, including painting with two coats of synthetic enamel paint over a coat of red oxide paint complete all as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in any type soil for laying pipes etc, complete all as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as directed.
Supply, install, test and commissioning of silent type Diesel engine driven Generating set of capacity 40 KVA/32 KW, 3 phase, 4 wire, 415 Volts, 50 Hz, at 0.8 pf (lag) with Diesel Engine, Alternator and control panel all mounted in acoustic enclosure complete confirming to the detailed specifications as given below :-
Diesel Engine : The diesel engine shall be of capacity suitable for alternator of capacity 40 KVA/32 KW developing required power for rated KVA not less than 39KW at 1500 RPM, 4 cylinders in-line, 4 stroke, radiator cooled, continuous duty with 10% overload capacity for any one hour in 12 hours of continuous running and consisting of following:- a) Radiator cooled b) Electrical Starter Motor 12V DC. c) 1No X 12 V battery, 90 AH rating with connecting leads and terminals d) Battery Charging Alternator e) Fuel System with electronic governor f) Full flow Spin-on lube oil filter g) Duel fuel filter with water separator h) Residential type silencer j) Dry type air cleaner k) Fly wheel and fly wheel housing l) First fill of lube oil & Coolant.
Alternator : The Alternator shall be of capacity 40 KVA/ 32KW, 415 Volts, at 0.8 pf(lag), 50 Hz, 3 phase, 4 wire system, suitable for operation at 1500 RPM. The Alternator shall be brushless type, screen protected, revolving field, self excited, self regulated through an AVR, copper wound, Class 'H' insulation, having ±1.0% voltage regulation (max) in static conditions and continuous duty operation.
Mounting Arrangement: Engine and Alternator shall be mounted on a common MS fabricated base frame with Anti Vibration Mounting Pads.
Fuel Tank: Integral fuel tank shall be of capacity not less than 110 Liters and provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning.
Acoustic Enclosure: The entire generator, prime mover, fuel tank and DG set control panel should be housed in a sound proof acoustic enclosure made of CRCA sheets with UV resistant powder coated and a structural/sheet metal base frame. The walls of the enclosure should be insulated with high quality noise absorbent and fire-retardant grade acoustic insulation material complying to IS 8183 for better sound attenuation so as to comply with the 75 dBA at 1 meter sound levels at 75% load under free field conditions as specified by MOEF/CPCB. The enclosure should be provided with the following:- (i) Suitable doors on all sides to enter in to the container for easy maintenance. All doors shall be provided with locks and handles for opening/ closing of doors. (ii) Suitable internal lighting to carry out easy inspection and maintenance. (iii) Air Inlet louvers designed to operate at rated load. (iv) Fluid drains for lube oil and fuel. (v) Fuel filling point with locking arrangement. (vi) Push button for emergency stop
Note for Item No. 31.0:- (i) PCC foundation for DG set as per manufacturer's recommendations shall be measured and paid separately under relevant items of Schedule 'A'. (ii) On successful installation, the DG set shall be subjected to load test as specified below :- Phase-I : No-load test for 01 hour in the presence of Engineer-in-Charge. Phase-II : Load test for 12 hours continuously (at 25% of full load for fist one hour, 50% of full load for second one hour, 75% of full load for third one hour, 100% load for next 08 hours and 110% of full load for last one hour). Resistive type load bank or Water Load, Fuel and testing instruments as required for load testing shall be arranged by the contractor and cost of the same shall deemed to be included in the quoted rate. (iii) Phase-II load test shall be carried out in the presence of testing officer nominated by accepting officer or IEM.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and directed.
Material and labour for PCC 1:4:8 Type D2 (40mm graded stone aggregate) as in base concrete for DG set foundation complete all as specified and directed.
Material and labour for PCC 1:2:4 Type B1 (20mm graded stone aggregate) including necessary form work for DG set foundation complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends etc for protection of LT cable XLPE grade 1100 Volts complete all as specified and directed.
Supply and fix in replacement of 80mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
Supply and fix in on load changeover switch in sheet steel enclosure, 125 Amps, 4 Pole, 415 Volts, 50 Hz complete all as specified and directed.
Material & Labour for Power Cables, Aluminum Stranded Conductor 50 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
Supply, installation, testing and commisioning of air cooled split type Invertor Air conditioner of 1.5 TR capacity comprising of one indoor and one outdoor unit, wall mounted type comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 Volts AC, single phase, 50 Hz, having minimum five star rated with and including inlet/outlet copper pipe for refrigerant between indoor & outdoor unit with flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed by Engineer-in-charge. Note: The cost of making hole / opening for passing inlet/ outlet copper pipes and clectrical cord and making good surface as original by plastering / applying putty/ whitewash/colour/distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect and wall mounting stand for outdoor unit as per directed by Engineer-in-charge.
Supply, connect & testing of automatic voltage stabilizer, wall mounted type for low voltage cut-off, single phase, AC, 50 Hz, 15 Amps rating ,suitable for input voltage range 160V-280V AC with 3min±20 sec delay for Air Conditioner Complete all as specified and directed by Engineer in charge.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4.0 sqmm + 1 run x 4.0 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge.Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length.
S&F, modular MCB protected plug & socket boardin sheet steel enclosure with 25A rated mini MCB and 25 A rated 3 pin plug , 240 Volt, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the exixting surface all as specified and directed.
Supply, installation & testing of Electric Water Heater storage type, vertical, 25 Liters capacity, minimum 3 Star rated, with heating element, PUF insulation, multifunction safety valve, adjustable knob for temparature setting and mild steel inner tank and outer body suitable for operating on 230V, 50 Hz, single phase AC supply including hot & cold water PVC connections and mounting on wall with suitable size & No. of anchor bolts complete all as specified and directed.
Supply and fix MCB 06 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed by Engineer-in-Charge.
M&L for Tube, 'medium grade' galvanized, with all fittings such as socket, bend, elbow, Tee, reducer, union etc of size 15mm bore and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for Tube, 'medium grade' galvanized, with all fittings such as socket, bend, elbow, Tee, reducer, union etc of size 25mm bore and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply and fix Bib tap, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix angle valve, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling fan, 1200mm sweep, 3 blade, white colour, energy efficient, 50W / 52W power cosumption, with minimum 310 RPM, 100% copper winding motor with and including down rod, canopy (02 Nos), GI fan clamp with rubber bush, GI nuts, bolts and split pins etc (without regulator) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose to connector of fan complete all as specified and directed by Engineeer-in-Charge.
.Supply, installation, testing and commisioning of reverse osmosis plant having 100 liter per hour stainless steel with Auto shutoff pattern and TDS adjuster Commercial UV + RO Water Purifier Plant, Ultraviolet and reverse osmosis purifier method, electric driven, 230 Volts AC, single phase, 50 Hz. , including inlet/outlet pipe for water between water cooler & purifier unit with PVC water supply pipe of suitable size and tab as recommended by manufacturer, including Pre filter as per ground water requirement and gate valve as per existing pipe line for connection between main line to RO plant line including pipe fittings and accessories etc. complete all as specified and directed by Engineer-in-charge. Note: The cost of making hole / opening for passing inlet/ outlet water pipes and clectrical cord and making good surface as original by plastering / applying putty/ whitewash/colour/distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. make: Livepure,aquadpure,Kent, Zhpure
Supply & installation, commissioning of Water cooler fully stainless steel, electric driven single phase,230V, 50Hz having approx storage 120 Ltr and nominal cooling capacity 60 Ltr/ Hrs.
HARNAM SINGH ANIL SINGH
ROHIT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .