Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.1 L+₹14,287.55 (0.35%)Rejected-Finance R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹42.5 L+₹1.5 L (3.76%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹43.7 L+₹2.7 L (6.63%)Rejected-Finance PLOT NO 52 BAKSHI NAGAR JAMMU 180001 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹43.8 L+₹2.9 L (7.00%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
5 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 c/o 56 APO
Provn of certain sanctioned work under AOR of AGE B/R Dett A at Naushera
2020_MES_400008_1
GER-62/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹96,000
Yes
12 Jan 2021
2 Dec 2020
7 Jan 2021
2 Dec 2020
5 Jan 2021
22 Dec 2020
60 days
Amount
Sch 'A' Part-I B/R Works Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4.00 Sqm each and removing to store complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for (unreinfored) complete all as specified and directed.
Pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
Factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
Preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in coping, benching, hold fast, water troughs, bed block and the like including weathering, slightly rounded or chamfered angle and throating incuding necessary form work complete all as specified and directed.
300mm MS ordinary rat tail spring of approved make including roller and roller plate complete all as specified and directed.
Aluminium anodized barrel tower bolts 150 mm long of extruded section all as specified and directed.
Aluminium anodized barrel tower bolts 200 mm long of extruded section all as specified and directed.
Extruded aluminium alloy handles size 150 mm fabricated type anodised complete all as specified and directed.
Butt hinges 100mm medium weight cold rolled mild steel complete all as specified and directed.
250 mm long mild steel sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
Aluminum alloy, anodised, sliding door bolt 200mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E- complete all as specified and directed.
MS tubular Box type window (double rebate and double shutter) of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge, corner welded to form a solid fused welded joint, handles shall be of z section welded with openable frame box steel section used in outer frame, shutter frame and central frame shall be ERW secton of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section of steel window to provide suitable arrangement of using tower bolt. Glazed, gauzed window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures with or without glazing bars complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section, in any position (framed work) complete all as specified and directed.
Dismantling fillets, posts, rails, rafters purlins etc under 40 Sqcm in section unframed work complete all as specified and directed.
Roof trusses (framed), trussed, purlins, cranes gantries, , rails and fastening and heavy brackets framing (beam, tea, angle, channel or flat section) including distance pieces, cleats, etc. conforming to Fe-410-W (Gde - E-250) quality A complete all as specified and directed.
Mild steel work as in wind ties using flat iron including all necessary drilling bolting, riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Mild steel screw bolts (Purpose made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long and diameter of shark exceeding 20mm but n exc 25 mm dia complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long and slote 18 to 20mm complete all as specified and directed.
4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjustacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions inlcuding dismantling of exisiting board and cover fillets complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Walling of random rubble masonry (except stone), uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 20mm thick on stone masonry in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20mm thick on stone masonry in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat wall care putty complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Demolition of cement concrete unreinforced in any position on roof slab complete all as specified and as directed.
25mm thick PCC type B0 1:2:4 (12.5 graded aggregate) as in sub base complete all as specified and directed.
50mm thick PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand(all by weight) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (Ist quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Glazed ceramic coloured tiles of size 450x 300x7mm thick as on vertical surface of wall such as skirting, dado, riser etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and as directed.
Demolition of reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground) complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Second class hard wood(Hollock) small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each, complete all as specified and directed.
Complete removal of exisiting treatment and applying two coats of distemper oil emulsion over a coat of wall care putty on old surface complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 No, floor door stopper, anodised aluminium snap beading, screws etc including powder coating of any colour (thickness of powder coating not less than 50 micron) complete all as specified and directed.
5.5mm thick sheet glass, ordinary quality fixed to aluminium doors in square exc 0.5 sq. m in each pane complete all as specified and directed.
12mm thick prelaminated partical board, interior grade both side decorative choice lamination fixed to aluminium doors or as in cup board cabinets similar works complete all as specified and directed
Brass mortice lock vertical type 100mm long with 4 levers complete all as specfied and directed.
40mm thick PCC type B-1 1:2:4 (20mm graded aggregate) as in padding in roof surface to maintain proper slope finishing concrete surface even and smooth without using extra cement complete all as specified and directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
75mm thick PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified directed.
Rendering 15mm thick in CM 1:4 on other fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified directed.
40mm thick plain cement concrete type B1, 1:2:4 ( using 20 mm graded stone agg.) in flooring finished even and smooth without using extra cement complete all as specified and as directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC casing & caping complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 68 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 68 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 68 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
Switch piano, flush type single pole, one way 15 Amp, 240 volts complete all as specified and directed.
Socket 2 in 1, 3 pin 5 amp flush type complete all as specified and directed.
Socket out let 2 in 1, multipurpose 5 & 15 Amp flush type complete all as specified & directed.
Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. Make Bajaj /Usha/havells/CG
Lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 07 watt complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 20 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F20WLED P/W or equivalent in Philips/Havells/Bajaj
Sheet metal enclosure MCB distribution board single pole & neutral 430 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting and chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification (Note-MCBs will be measured and paid for separately).
Sheet metal enclosure MCB distribution board single pole & neutral 430 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including cutting and chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification (Note-MCBs will be measured and paid for separately).
MCB SP 240 volt any rating from 5 to 32 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB SPN 240 volts 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
Street light fitting LED 30 watt (18x25) made up of grey powder coated pressure die cast aluminium housing having IP66 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-30-CDL or its commercially and technically equivalent in Bajaj/Philips/Havells/C&S Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for laying of cable and foundation of poles and stays and n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Sand cushioning to underground cable, provided with a layer of 8 cm deep before laying the cable and 15 cm thick after laying and stretching jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed. complete all as specified and directed.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
GI pipe 40mm bore light grade (ISI marked) with all fitting fixed to wall, poles or under road crossing etc with suitable size clamps for protection of cable complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete all as specified and directed.
Street light bracket made up of 40mm bore light grade GI pipe 1.2 mtr long including necessary bending welding etc complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 10 watts, 2 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTDC01210WLED/WD or equivalent in Philips/Havells/Bajaj
Supply and fix in replacement high efficacy 2'x2' recess LED flat panel light 36W LED 2700/3000K (warm white) edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Havells/Bajaj/Crompton/Halonix.
S50 Duo Shadow less OT light ceiling mounted 5 in 1+5 in 1 slim Double Dome LED OT Light, No of domes-02 Nos, Aerodynamically designed alluminium dome for modern laminar flow OTs, Sterlizable Handle for focusing Drift free Spring Rotation of 360 degree Dome diamenter 630mm +630mm Field-145mm to 280mm Higher filed depth of 750 for proper vision in deep cavity Colour temp 4100K CRI 90 intensity control in the dome head/SMPS Focus adjustable Two straight handles autoclavable for each dome Nos of high LES-35+35 Nos High out put of 135000+135000 lux SMPS-02 Nos with intensity control-step less control facility Make - Philips or equivalent model in Bajaj/Havells/C&S as approved by GE.
MCCB DB suitable for fixing MCCB 4 pole 100 Amps as incomer and MCB as out going complete with size of busbar, making cable connection for incoming and out going cables inlcuding making good to disturbed surface etc complete all as specified and directed. Note MCB will be paid separately under respective items.
MCCB DB suitable for fixing MCCB 4 pole 100 Amps 25KA as incomer and MCB as out going complete with size of busbar, making cable connection for incoming and out going cables inlcuding making good to disturbed surface etc complete all as specified and directed. Note MCB will be paid separately under respective items.
MCB TPN 63 Amps, 50 HZ, breaking capacity not less than 10 KA complete all as specified and directed.
Sheet metal enclosure single pole and neutral with two pin and earth plug and socket with one single pole MCB 20 amp complete all as specified and directed.
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor as earth continuity conductor drawn through and including 25mm dia rigid PVC conduit and conduit accessories fixed on wall/floor/ceiling etc all as specified and as directed. Note: 03 runs of cable and one run of conduit shall be measured as one unit.
Sub main wiring complete with 2 runs of 6 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 6sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor as earth continuity conductor drawn through and including 25mm dia rigid PVC conduit and conduit accessories fixed on wall/floor/ceiling etc all as specified and as directed. Note: 03 runs of cable and one run of conduit shall be measured as one unit.
Supply, installation and testing of air cooled split unit air conditioner electric driven (single phase), copper kit for cooling and heating type of capacity 4500 K cal per hour 1.5 Ton, 3/5 star rating with remote control, wall mounted with suitable arrangement including all piping etc. complete all as specified and directed. Make :- LG/Voltas/Blue star/Samsung.
Copper wound Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 to 260 V with output voltage stabilized at 230 volts with accuracy ± 2.5% 50 Hz of capacity 5 KVA complete all as specifed and directed.
Cutting existing steel tubing 15mm for alterations or additions (Each cut measured) complete all as specified and directed.
Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces, single branch, "Y" junction, double branch cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore complete all as specified and directed.
15mm bore galvanized steel water tubing with screwed and socket joints medium grade together with all fittings such as elbow, unions, nipples, tees, bends, short pieces, connectors, check-nuts, caps, plugs, diminishing pieces etc fixed to wall or ceiling or laid under floors including necessary cutting chaises and making good in CM 1:3 complete all as specified and directed.
15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe, suitable for 15 mm bore complete all as specified and directed.
Storage water Heaters verticle type ( Geysers) of cap 25 Ltrs , 5 star rated as per BEE norms electrically operated suitable for 230 volts , 50 HZ AC supply system complete with porcelain/glass coated insulated heating element, copper inner tank, external thermostate including CP connections grouting of suitable nut, bolts etc complete all as specified and directed. Make Bajaj shakti /CG/ Venus/ Ditz.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
vijay kumar
RAJINDER CHOUDHARY
M/S Jasbir Singh
M/S Narinder Pal Choudhary
M/S. Choudhary Dewan Chand And Sons
CHAND CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .