Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC 301 VIVEK VIHAR SODALA JAIPUR RAJASTHAN 302019 | JAIPUR | RAJASTHAN | 302019 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹9.2 L+₹2.7 L (41.5%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹9.2 L+₹2.7 L (41.7%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L3 | Rejected-Finance L3 | |
| 4 | L4₹9.7 L+₹3.2 L (49.0%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹10.0 L+₹3.5 L (53.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
14 May 2024, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
ANNUAL MAINTENANCE CONTRACT OF SOLAR PLANT AT 09 LOCATIONS UNDER GE (S) JAIPUR
2024_MES_646931_2
CWE/JPR(S)/82326/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
JAIPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE SOUTH JAIPUR
₹20,000
Yes
5 Jun 2024
22 Apr 2024
16 May 2024
22 Apr 2024
14 May 2024
30 Apr 2024
22 Apr 2024 - 29 Apr 2024
Amount
The Contractor shall provide fully comprehensive annual maintenance from any one of the OEMs or authorized service dealer of OEMs intended to provide service.
Fully comprehensive annual maintenance of Solar Plant at following 9 locations at Jaipur Military Station : (i) 300 KW -01 (School zone-I) (ii) 220 KW -01 (OTM Accn Zone-III) (iii) 150 KW -02 Nos (OTM Accn Zone-III) (iv) 116 KW -01 (HQ SWC COMMAND) (v) 66 KW -01 (HQ 322 BDE) (vi) 33 KW -03 Nos (ADM BLOCK ZONE-III)
The AMC of the solar plant shall includes following scope : a. Module washing fortnightly (Minimum twice a month or more frequent if required) b. Generation Monitoring c. Checking and identify Hotspot on module (white dots / Brwon color) d. Checking of Module damages/crakes (Make - Warree) e. Checking of temporary shadow on Modules f. Checking of all inverter of rating (20/33/50/100) KW parameteres (VOC, AC DC Voltage, power etc.) twice a month g. String monitoring in all MPPTS h. Inverter reading (Make-Sungrow) i. Visually check condition of Inverter fans and bowering j. Solar Meter reading k. Visually check condition of ACDB and DCDB I. Visually checking of heating issue on termination point of all equipments m. All termination gland condition & cable stress n. SPD (Make - Citel)
NOTES FOR ITEM NOS 1.01 :- (a) After approval of OEM by GE, Contractor shall submit the MOU between the contractor and OEM (b) The scope of works includes the following and rate quoted shall be deemed to be included in this provision. (c) The scope covers all petty repair/replacement and maintenance such as DC cable/MC4 connectors/communication cable of the solar plant however major equipment failure like Inverter/ ACDB/Solar panels/SPDS or any major items etc will be provided by MES under Sch 'B'. The make of the major items 'shall be of the same make available on the site. (d) Reporting and Documentation: Monthly submission of performance report by 7th of each month for preceding month. Monthly Performance report should include the following: i. Preventive maintenance Report ii. Corrective Maintenance Report iii. Chart Showing Comparative power generation of each month (f) The maintenance shall be performed by OEM or authorised service dealer of OEMS
M/S GAURI CONSTRUCTION
M/s Yash Electrical and Maintenance
BLAZE POWERTECH
S.R.Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .