Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC VILL POST UDAMBAR PS REMUNA DIST BALASORE ORISSA | BALASORE | BALASORE | ORISSA | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹43.0 L+₹1.5 L (3.69%)Rejected-Finance AT SRIKONA PS CHANDIPUR DIST BALASORE ODISHA 756 025 | CHANDIPUR | BALASORE | ODISHA | 756025 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹43.5 L+₹2.0 L (4.89%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹43.9 L+₹2.4 L (5.78%)Rejected-Finance NEAR CENTRAL SCHOOL CHHAK BHOISAHI BALASORE ORISSA 756001 | BALASORE | BALASORE | ORISSA | 756001 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹44.1 L+₹2.6 L (6.32%)Rejected-Finance 10 8A BEJOYGARH KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
Refer Docs
EMD Value
₹82,660
Closing Date
28 Mar 2025, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
SPECIAL REPAIR TO BLDG NO P 191 TYPE III AND P 192 TYPE II AT PM SHRI KV NO 1 STAFF QTR UNDER AGE B AND R BALASORE
2025_MES_700676_1
8128/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE I R AND D CHANDIPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹82,660
Yes
8 May 2025
7 Mar 2025
29 Mar 2025
7 Mar 2025
28 Mar 2025
21 Mar 2025
Amount
NOTE (Applicable for all items) :- (i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. (ii) The bidders / contractors are advised to quote same rate for same items as mentioned in Part-I, Part-II, Part-III & Part-IV, if quored rates are different for same items, lower quoted rate shall be considered for same items as mentioned in Part-I, Part-II, Part-III & Part-IV. For this account nothing extra shall be admissible by this Deptt. SCHEDULE 'A' PART-I (Building)
Dismantling of floor hearth or wall tiling, granite/kota stone slab including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
M&L for rendering 10mm thick cement plaster in CM (1:4) on fair faces of brick work for fixing of wall tiling complete all as specified and as directed.
M&L for 15 mm thick screed bed or bedding layer of cement mortar in CM(1:6) for laying floor finishes for non skid ceramic and granite slab complete all as specified and as directed.
M&L Glazed ceramic colour tiles in vertical surface 450 X 300 X 6-7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
M&L Non Skid colour ceramic tiles 6 to 8mm thick area of each tile exceeding 0.06 Sqm but not exc 0.11 Sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles complete all as specified and directed.
M&L Non Skid coloured ceramic tiles 6 to 8mm thick area of each tile exceeding 0.11 Sqm but not exc 0.18 Sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles complete all as specified and directed.
All as per item 1.06 above but as in skirting.
M&L granite slab (of any type) 16-18 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including cutting and polishing complete all as specified and directed.
S&F for 20-22 mm thick Kota stone slab flooring over 15 mm thick screed bed in cement mortar CM (1:4) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete all as specified and directed.
S&F for 20-22 mm thick Kota stone slabs in risers of steps, skirting, dado and pillars laid on 10mm thick cement mortar CM(1:3) backing and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing all complete as specified and directed.
Demolition of unserviceable RCC over head tank (reinforcement cut as required to facilitate demolition) concrete of any description and in any position not otherwise specifically provided and remove the debris from the site complete all as specified and directed.
M&L 75 mm thick Cement concrete type C-1, (1:3:6) (using 20mm graded aggregate) under PVC water tanks and finished the concrete surface even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 10mm thick in CM (1:6) rendering on brick wall or concrete surfaces finished the surface even and fair complete all as specified and directed.
M&L for 5mm thick cement plaster in cement mortar CM (1:3) on ceiling, and finished the surface even and fair complete all as specified and directed.
M&L for 15mm thick cement plaster on fair faces of brick wall or concrete surfaces in CM (1:4) and finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for two coats of acrylic oil emulsion distemper over a coat of primer in newly plastered surfaces of walls of any description including 1.00 mm wall care putty including preparation of surfaces complete all as specified and as directed.
M&L for complete removal of existing treatment of wall surfaces and applying two coats of acrylic oil emulsion distemper including a coat of primer including 1.00 mm wall care puty etc complete all as specified and directed.
M&L for preparing newly plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surface of wall and applying three coats of white wash complete all as specified and as directed.
M&L for two coats of white wash on wall surfaces including preparation of old decorated surfaces complete all as specified and directed.
M&L for two coats of white wash on ceiling surfaces including preparation of old decorated surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and finishing wall with acrylic smooth exterior wheather coat paint of required shade (Two or more coat applied @ 1.67 lit/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and as directed.
M&L for complete removal of existing treatment and finishing walls with acrylic smooth exterior wheather coat paint of required shade (Two or more coat applied @ 1.67 lit/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from frame) area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down PVC chowkhats or frames with shutters (without taking off shutters from frame) area not exceeding 1.8 Sqm each complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from frame) area exceeding 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed.
Taking down and refixing shutter after repair of any description exc 1 Sqm but n. exc 2 Sqm each in same opening complete all as specified and as directed.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters, railings; framework of water tanks and similar work, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for preparation of old painted surface of wood and wood based surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new painted surface of wood surfaces of any description exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparing of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site complete all as specified and as directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with ms square tube, in opening as per specification and drawing complete all as specified and as directed.
M&L 2nd class hard wood plain, solid, straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
S&F 30mm thick Flush shutter, solid core construction with block board core and plywood face panel, commercial type both sides complete all as specified and as directed.
S&F 30 mm thick 2nd class hard wood glazed, gauged, skeleton shutter, as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats open rebated and prepare to receive glass, gauge etc divided into squares edges of framing, plain, chamfered or rounded, mitred and rebated sash bars any numbers prepared to receive glass/ gauge complete all as specified and as directed. Note : Wire mesh/glass shall be measured and paid separately.
Dismantling wooden boardings thickness 10mm up to 25mm in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead complete all as specified and directed.
S&F 18-19 mm venerred decorative plywood, Grade-1 (with BWR resin) with decorative face veneers on both faces, fixed with screws to timber frame work complete all as specified and directed.
M&L 2nd class hardwood Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 6 Sqcm but n.exc 13 Sqcm incl 02 coats of synthetic enamel paint over a coat of primer including taking down old fillets complete all as specified and as directed.
S&F for powder coating minimum thickness 50 micron Anodised aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and as directed.
S&F for powder coating minimum thickness 50 micron anodised aluminium window shutters sliding/openable type and ventilator louvered type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each window, hinges, anodised aluminium snap beading screws etc complete all as specified and as directed. Note : Glass and wire mesh shall be measured and paid separately.
S&F 4mm thick figured glass, pin head type and glazing with securing clips complete all as specified and directed.
M&L for 5.00 mm thick sheet glass, ordinary quality incl necessary fixing complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with SS wire stapple complete all as specified and as directed.
S&F 150 mm long aluminium, anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm extruded aluminium alloy handles, fabricated type, anodised cast type, anodised complete all as specified and directed.
S&F aluminium sliding door bolt 250 mm long, plate type, stove enamelled black, with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F butt hinges medium weight, cold rolled mild steel of size 100 mm complete all as specified and directed.
S&F Stainless steel butt hinges of size 100 mm complete all as specified and directed.
S&F 100 mm floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor.
Taking up or down GI water tubing and connecting incl cleaning for refixing or removal for 20mm bore complete all as specified and as directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl all fittings complete all as specified and as directed.
Cutting chases not exc 15 cm girth for concealed water tubing and making good to facings where required and pointing in cement mortar CM (1:3) complete all as specified and directed.
S&F in repair 15mm dia fancy type CP bib taps, cast copper alloy with crutch or butterfly handle, screwed down fixed complete all as specified and as directed.
S&F in repairs 15mm dia CP angular stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions complete all as specified and as directed.
S&F in repair shower rose fancy type chromium plated 120 mm (minimum) size with swivel joints suitable for 15 mm bore pipe including shower arm chromium plated 15 mm dia, 190 mm (minimum) long complete all as specified and directed.
S&F in repair CP tubular towel rail, 20mm dia, "D" type, 60 cm long between flanges complete all as specified and as directed.
S&F fixed in repairs Grating doom 125 mm dia size of PTMT (minimum weight 40gms) complete all as specified and directed.
S&F PVC connection of 15mm size with PTMT nuts of length 600mm long complete all as specified and as directed.
S&F in repairs 10 Liters capacity, low level flusing cistern, PVC, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed.
S&F in repairs wash down water closet (EWC) complete white with plastic water closet seat white closed pattern with flat bottom anc cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or density or PVC 32mm dia for low level flushing cistern complete all as specified and directed.
S&F in repairs Vitreous china Squatting pan Orissa pattern of size 580mx440mm white with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding complete all as specified and directed.
S&F in repairs vitreous china wash basin, white, flat back size 550x400mm, incl cutting for and pinning in ends of brackets or erecting stand but excl taps, pvc conections but incl brackets, waste pipe, waste coupling complete all as specified and directed.
S&F in repairs 15mm dia fancy type CP pillar taps, cast copper alloy with capstan head, chromium plated screwed down fixed high pressure, long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches complete all as specified and as directed.
S&F in repair 40 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) junction single (Single "T") equal or unequal with access door complete all as specified and as directed.
S&F in repair 110mm bore PVC (SWR) junction single (Single "T") equal or unequal with access door complete all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S&F in repairs 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
S&F 500 litre capacity rotational moulded polythylene tripple layer water storage tank with cover and suitable locking arrangement (cylindrical vertical with closed top) hoisted and fixed in position incl dismantling of water tank complete all as specified and directed.
S&F PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore complete all as specified and directed.
S&F in repair 20 mm CPVC Ball Valve (Gate Valve) complete all as specified and directed.
S&F in repair 110mm PVC SWR vent cowl complete all as specified and directed.
S&F in repair for Health Faucet (ABS) with 1 Mtr. Tube & Hook complete all as specified and directed.
S&F in repairs two way Bib cock/tap, fancy type, chromium plated, cast copper alloy screwed down, screwed for iron pipe or for brass ferrule and fixed to 15 mm bore pipe complete all as specified and directed.
S&F in repair soap dish, any type, fixed to plugs with chromium plated screws complete all as specified and directed.
S&F in repair stainless steel fancy type 20mm dia curtain rod of 1.25mm thick wall thickness including bracket and all accessories complete all as specified and directed.
S& F in repairs 75 mm PVC Nahani Trap complete all as specified and directed.
S&F in repair Stainless steel kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including 600mm long flexible waste PVC pipe, painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board (915mmx460 mm x 0.8mm thick bowl size 410mm x 330mm and bowl depth 160 mm) complete all as specified and directed.
M&L for 50mm thick PCC 1:3:6 type C2 (20mm stone aggregate) as in plinth protection, paving finised the surface even and smooth without using extra cement complete all as specified and directed.
SCHEDULE 'A' PART-II (Road/Culvert/Path) NOTE :- (i) The connected items which are not catered in this part and the items which are technically required for execution of this part, the same shall be measured and paid under Part-I here-in-before and in this account nothing extra shall be admissible to the bidders / contractors by Deptt.
Demolition of cement concrete (unreinforced) in ground floors and pavings, etc. n exc 15cm thickness (below or above ground level) as in surface channel, coping etc. and removing debris and rubbish out of the premises complete all as specified & directed.
M&L for 75 thick plain cement concrete 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for sand filling under paver block incl watering and consolidation complete all as specified and directed
M&L for Machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment complete all as specified and directed.
SCHEDULE 'A' PART-III (Area Draunage) NOTE :- (i) The connected items which are not catered in this part and the items which are technically required for execution of this part, the same shall be measured and paid under Part-I & Part-II here-in-before and in this account nothing extra shall be admissible to the bidders / contractors by Deptt.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & directed.
M&L for Brick work with flyash bricks old size, straight or curved on plan exc 6 m mean radius built in cement mortar(1:6) etc complete all as specified & directed.
M&L Brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified & directed.
M&L for 15mm thick rendering in cement mortar CM (1:6) on brick or concrete surfaces of wall finished even & smooth without using extra cement complete all as specified and directed.
M&L plain cement concrete (1:2:4), type B-0 (using 12.5 mm graded stone aggregate) as in coping, bed plates, kerbs, etc. complete all as specified and as directed.
M&L for plain cement concrete (1:3:6), type B-2 (using 40 mm graded stone aggregate) as in surface channels and drains, etc.complete all as specified & directed.
Extra for forming fair finished of drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped complete all as specified and directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm girth
SCHEDULE 'A' PART-IV (Internal Electrification) NOTE :- (i) The connected items which are not catered in this part and the items which are technically required for execution of this part, the same shall be measured and paid under Part-I, Part-II & Part-III here-in-before and in this account nothing extra shall be admissible to the bidders / contractors by Deptt.
Taking down carewfully copper/aluminium point wiring (light,fan socket or power) complete,including fixture and fitings such as switches,ceilling rose,pendants regulsators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separaterly) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
Material and labour for one light point or one fan point controlled by one switch wiring with copper conductor(FRLSH) PVC insulated unsheathed cables of size 1.5 Sqmm 2 run and one run of 1.5 Sqmm for earth continuity to be drawn in PVC concealed conduit non metallic not less than 20mm width MS sheet metal switch/terminal box 1.2mm thick and Hylum sheet switch including all necessary wall cutting for sinking's of boxes abd making good disturbed surface to walls complete all as specified and directed.
All as per item 4.02 above but for 3 pin socket outlet 5 Amps independent point wiring with 2 x 1.5 Sqmm copper conductor cable and 1.5 Sqmm copper conductor cable as earth continuity conductor.
All as per item No 4.02 above but for 3 pin socket outlet on same board for point wiring with 2 x 1.5 Sqmm copper conductor cable and 1.5 Sqmm copper conductor cable as earth continuity conductor.
All as per item no 4.02 above but for 3 pin socket outlet 6/16 Amps independent point wiring with 2 x 4 Sqmm copper conductor cable and 4.0 Sqmm copper conductor cable as earth continuity conductor.
All as per item no 4.02 above but for one bell/buzzer point controlled by one bell push button on the same board with other switches or independent with 1.5 Sqmm copper conductor cables.
All as per item No. 4.02 mentioned here in above but for one light point controlled by two way switches ditto complete all as specified.
Taking down sub main/Sub circuit wiring of any type and size including conduit/casing capping/batten wiring for necessary repair/replacement complete all as specified and directed.
M&L for wiring for sub main/Sub circuit wiring using (FRLSH) PVC insulated copper conductor cable of size 2 x 6 Sqmm along with 1 x 6.0 Sqmm single core cable for earth continuity to be drawn in PVC non metalic conduit/recessed as directed by Engr-in-charge.Note : Two runs of 6.0 Sqmm and one run of 6.0 Sqmm cable including conduit pipe shall measured as one length complete all as specified and directed.
Supply and fix sub-main/Sub circuit wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH) 1100 Volt grade alogwith one run of 4.0 sqmm PVC insulated & unsheathed copper conductor cable (FRLSH),1100 Volt grade,connected to common earth dolly as earth continuity conductor,drawn through PVC conduit for conceeled including all accessoriesd existing one complete all as specified and as directed by the Engr-in-Charge. Note : Two runs of 4 Sqmm and one run of 4.0 Sqmm cable including conduit pipe shall measured as one length
M&L switch piano flush type single pole one way 5/6 Amp including connections complete all as specified and directed.
M&L switch piano flush type single pole two way 5/6 Amp including connections complete all as specified and directed.
M&L switch piano flush type single pole one way 15/16 Amp including connections complete all as specified and directed.
Supply and fixing of call bell,230V AC.single pole complete all as specified and directed.
Supply and fixing of bell push, flush type, 5 Amp complete all as specified and directed.
Supply and fixing of Socket outlet 3 pin, 5/6A, flush type including connection complete all as specified and directed.
Supply and fixing of Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type including connection complete all as specified and directed.
M&L ceiling rose PVC poly carbonate,isolated body with three terminals including connection complete all as specified and directed.
S&F stepped type electronics fan regulator flush type 230/240V complete all as specified and directed.
M&L lamp holder angular type PVC/Polycarbonate type insulated body with back plate complete all as specified and directed.
Taking down unserviceable sheet metal MCB/DB box 8 way & main DB/main switch etc for necessary repair/replacement complete all as specified and directed.
Supply and fixing of MCB DB double door made of sheet steel phosphates powder painted with bus bar, neutral link,earth bar and din rail ,SPN 8 way 240V (Blank slots covered by Blanking plate) complete all as specified and directed.
All as per item 4.22 above but tripple pole and nutural 04 way,415V
Supply and fixing 415V 10KA 'C' curve TPN miniature circuit breaker (MCB) of four poles and 100 Amps current carrying capacity in the DB complete with connection testing and commissioning.
Supply and fixing 240V, 10KA 'C' curve SPN miniature circuit breaker (MCB) of two poles and 63 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing 240V, 10KA 'C' curve SPN miniature circuit breaker (MCB) of two poles and 40 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing 240V, 10KA 'C' curve SPN miniature circuit breaker (MCB) of two poles and 20 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing 240V, 10KA 'C' curve SP miniature circuit breaker (MCB) of single poles and 10-32 Amps current carrying capacity in the MCB DB complete with connection testing and commissioning.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion complete all as specified and directed.
M&L for fixing of earth contuninity conductor or main earthing lead aluminium strip 25x4 mm with shaddle,nut,bolts etc on existing roof conductor and down conductor fixed with and including fixing accessories and connecting to ground conductor complete.
Supply & fix LED tube light along with fixture 20 W LED type intigrated batten fitting complete all as specified and directed.
Taking down ceiling fan including dismantling blades and removing fan and blades complete all as specified and deposit in the store complete all as specified and directed.
M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and hanging of ceiling fan including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
M&L for cutting openings, through brick walls for exhaust fan hole including ,cleaning and stacking bricks, removing surplus serviceable bricks and rubbish not exc. 50m including making good disturbed surface of wall wih cement mortar 1:4 complete all as specified and directed.
Supply and fixing LED building security light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
M&L for bracket for security light fitting made out of 40mm light grade GI pipe bended one portion of 45cm at 120° to shape of approx. length 1.5 mtr including 2 no MS clamp of flat iron size 40×6 mm complete with nut bolt washer complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc complete all as specified and directed.
M&L for taking down & refixing of energy meter including GI Box with cover, wiring at respective quarter near the distribution box complete all as specified and directed.
Material and Labour for 20 mm dia bore pipe Galvanized Iron water tubing " Medium Grade" with all fittings fixed complete to wall/ceiling or laid under floor etc complete all as specified and directed.
Material and Labour for 25 mm dia bore pipe Galvanized Iron water tubing " Medium Grade" with all fittings fixed complete to wall/ceiling or laid under floor etc complete all as specified and directed.
Supply and fix in repair 20 mm dia bore pipe Gun metal globe or gate valve ISI marked high pressure with iron wheel head screwed both ends for iron pipe line complete all as specified and directed.
Supply and fix in repair 25 mm dia bore pipe Gun metal globe or gate valve ISI marked high pressure with iron wheel head screwed both ends for iron pipe line complete all as specified and directed.
M/s Manas Ranjan Bera (BID ID -3271782)
M/S BIJAY KRUSHNA MAITY (BID ID -3272777)
DANWAR AND ASSOCIATES (BID ID -3271717)
M/s D.K Mukherjee & Co (BID ID -3271711)
vaishnaveedevienterprises (BID ID -3271667)
M/S T.N.CONSTRUCTION (BID ID -3272373)
RANA ENTERPRISES (BID ID -3271704)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .