| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹37.8 L+₹92,086 (2.50%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹39.3 L+₹2.4 L (6.50%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹40.6 L+₹3.7 L (10.0%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹40.6 L+₹3.7 L (10.2%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Aug 2023, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
REPAIR/MAINTENANCE OF UNSERVICABLE NURSING CALL BELL SYSTEM ALONG WITH DISPLAY PANEL AND REMOTE PUSH SWITCHES, BED SIDE LAMPS, OT LIGHTS, OT SENSOR DOORS AND CONNECTED MISC E/M WORKS AT DIFFERENT WARDS AT BHDC UNDER GE (EAST) DELHI CANTT-10
2023_MES_610424_1
GE/DE-53/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) DELHI CANTT-10
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹90,000
Yes
23 Nov 2023
24 Jul 2023
2 Sept 2023
24 Jul 2023
31 Aug 2023
17 Aug 2023
Amount
S & F in repair of Handy and light weight remote control for patients with remote with jacket to fix mount on wall and having Battery type: 12volts DC / 23A & Range indoors: 20-30 meters complete all as specified and directed. Make: Model No.(FBX521) in FORBIX SEMICON or equivalent in honeywell/ hochiki.
S & F in repair of 4-digit receiver display Operates on 12VDC (comes along with 220-110VAC converter) having display size of extra large alphabets complete all as specified and directed. Make : - Model No.FBXCSL04A in FORBIX SEMICON or equivalent in honeywell/ hochiki.
S & F in repair of Repeater booster enhances the range of signals furthermore high power repeater provides additional 50-60meters and additional repeater improves the signal to noise ratio (SNR), at some multiple repeaters in series are required complete all as specified and directed. Make :Model No.(FBXCSRPT01C) Signal booster repeater in FORBIX SEMICON or equivalent in honeywell/ hochiki.
S & F in repair Power supply adapter converter of input as 220vac to 12v dc as out put complete all as specified and directed.
S & F in repair alkaline battery 23A 12V as out put complete all as specified and directed.
Supply & Commissioning in repair of UL 864 10th edition UL Listed and FM approved Analog addressable 1 Loop Fire Alarm Control Panel having the total panel capacity of 252 devices. The panel shall be able to give pin point location of all Fire /fault and Isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing up to 10000 events. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 2”x4-3/4” Size VGA monochrome LCD display and having maximum 320 (8 x 40) Characters in the display with optional 24 Zones LED indicators. The panel shall have a built-in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries of up to 33AH capacity. The Panel shall have the capacity of connecting additional 31 panels or Network terminals using network card, with redundancy in the network. The panel shall have the capacity of connecting maximum 16 Remote terminals /16 remote displays or combined by using 2 X RS 485 Card complete all as specified and directed MAKE- Siemens/Bosch/Hochiki
Supply & Commissioning in repair of UL 864 10th edition UL Listed and FM approved Networkable Repeater Panel. The panel shall be able to give pin point location of all Fire /fault and Isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing up to 10000 events. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 2”x4-3/4” Size VGA monochrome LCD display and having maximum 320 (8 x 40) Characters in the display with optional 24 Zones LED indicators. The panel shall have a built-in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries of up to 33AH capacity. The Panel shall have the capacity of connecting additional 31 panels or Network terminals using network card, with redundancy in the network. The panel shall have the capacity of connecting maximum 16 Remote terminals /16 remote displays or combined by using 2 X RS 485 Card.complete all as specified and directed MAKE- Siemens/Bosch/Hochiki
Supply & Commissioning in repair of UL268 6th and 7th edition compliance and FM approved Intelligent Addressable Smoke detector complete with standard base, facility to mount in different comprehensive environment, Tri-color detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self-diagnostics and supervision programs, Field programmable, Polarity insensitive, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature in detector shall consider Isolator base in place of standard base OR separate Isolator before and after every detector.complete all as specified and directed MAKE- Siemens/Bosch/Hochiki
Supply & Commissioning in repair of UL listed and FM approved Intelligent addressable Class X type (Style 7), Manual Pull Station Single Action, Shock and Vibration Resistant, with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal, Yellow for Faulty and RED for activation), T-45 Key Reset lockset for easy maintenance, Operating Temp and RH: 0-49degC and <=95%. MCP shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every MCP to comply the same without any extra cost.complete all as specified and directed. MAKE- Siemens/Bosch/Hochiki
Supply & Commissioning in repair of UL listed and FM approved Intelligent addressable Class X type (Style 7), Control Module with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal, Yellow for Faulty and RED for activation), Operating Temp and RH: 0-49degC and <=95%. Module shall have in-built isolator for better reliability, circuit integrity and advanced fault finding. Manufacturers not having in-built Isolator feature shall provide separate Isolator before and after every Module to comply the same without any extra cost. (For AHU & Staircase Pressurization Fans, Hooters etc.) complete all as specified and directed. MAKE- Siemens/Bosch/Hochiki
Supply & Commissioning in repair of UL Listed Hooter rated at Continuous Horn settings shall each be 87 dBA Anechoic minimum at 24VDC. It shall have provision for standard reverse polarity-type supervision complete all as specified and directed MAKE- Siemens/Bosch/Hochiki
Supply & laying in repair of 2CoreX1.5Sqmm of FRLS Copper Cable, complete all as specified and directedMAKE- Polycab/Fusion/KEI.
Supply & laying in repair of 20mm dia. PVC ISI marked Conduit. complete all as specified and directed. MAKE-AKG/BEC/NORPACK/PLAZA
Supply, installation, commissioning and testing in replacement of LED based ceiling suspended 50 double dome Operation Theater Light with provision only for Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601-2-41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring from and hanging arrangements as per manufacturers guidelines with following specifications :-
TECHNICAL SPECIFICATION MAIN DOME SATELLITE DOME Intensity @ 1 Meter (Lux) 1,60,000 + 10% 1,60,000 +10% Adjustable Field diameter (cm) 14-38 14-38 Depth of illumination L1+L2 (cm) > 100 > 100 Color Rendering Index (CRI) (Ra) 95 + 3% 95 + 3% Color temperature (K) 4,500 + 10 % 4,500 + 10 % Intensity control (%) 25-100 25-100 Type of field focusing control By sterllizable handle By sterllizable handle Type of Intensity control By control panel on lamp head By control panel on lamp head
ELECTRICAL & MECHANICAL SPECIFICATIONS Power Supply input voltage (V) 220-230 V Power Consumption (W) < 150 Frequency (Htz) 50/60 Dome Diameter 600-700 mm LED service life (hrs) > 40,000 Make :- Philips/Dr Mach/Hospedia medicare/ Stryker. Note :- The contractor shall submit the details of Make/Model/Specification of the OT light for approval of GE before placing order. The Make and Model of OT light shall fulfill the requirement given here-in-before. In case of any discrepancy/ difference of opinion, the decision of Accepting officer shall be final and binding and nothing extra shall be paid on this account.
S & F in repair of LED 50 inner 8 port circuit complete all as specified and directed.
S & F in repair of LED 50 outer controller circuit complete all as specified and directed.
S & F in repair of LED 50 keypad complete all as specified and directed.
S & F in repair of LED 50 LED's, 6 LED's with lens complete all as specified and directed.
S & F in repair of LED 50 SMPS(switching mode power supply) with lens complete all as specified and directed.
S & F in repair of extra sterilizable handle (yellow/white colour) complete all as specified and directed.
S & F in repair of 650 VA UPS complete all as specified and directed.
S & F in repair of 650 VA UPS Batteries complete all as specified and directed.
S & F in repair of 650 VA UPS Circuit complete all as specified and directed.
M & L LED 50 OT Light Double Dome unit Inspection , cleaning and testing of LED 50 Double Dome Unit rewiring of the entire unit , Revalidation of the internal circuitry and control panels for the proper functionng of the unit and complete inspection all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc shall be measured and paid separately) and making good disturbed surfaces of wall floor etc complete all as specified and as directed.
M&L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded, copper conductor Cable, FRLS, 1100 Volt grade, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 25mm dia or as per site requirement with all fittings, including cadmium plated screws as per IS, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, suitable for One light/fan/bell point controlled by one No, 5 Amp, one way switch/bell push complete all as specified and as directed. Make- Polycab/Havells/Finolex.
All as per item No.28.00 here in before but for one three pin, 5 Amp, socket out let on independent board complete all as specified and as directed. Make- Polycab/Havells/Finolex.
All as per item No. 28.00 here in before but for one three pin, 5 Amp, socket out let on same board complete all as specified and as directed. Make- Polycab/Havells/Finolex.
All as per item No. 28.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet on independent board with 2.5 Sqmm size earth conductor complete all as specified and as directed.Make- Polycab/Havells/Finolex.
All as per item No. 28.00 here in before but point wiring with 2.5 Sqmm, multistranded, copper conductor cable, for 15 Amps socket outlet onSame board with 2.5 Sqmm size earth conductor complete all as specified and as directed. Make- Polycab/Havells/Finolex.
All as per item No. 28.00 here in before but point wiring with 4 Sqmm, multistranded, copper conductor cable, for AC point on independent board with 4 Sqmm size earth conductor complete all as specified and as directed. Make- Polycab/Havells/Finolex.
S&F in replacement modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular switch, 1 way, 16 Amp, 1 Module, complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular Socket, 6Amp, 2/3 Pin, combined, 2 module complete all as specified and as directed.Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular cover plate with frame, 3 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular cover plate with frame, 4 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular cover plate with frame, 6 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular metal flush box, 3 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular metal flush box, 4 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement modular metal flush box, 6 modules complete all as specified and as directed. Make- Anchor Roma /Legrand/Crabtree
S&F in replacement sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 20 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 6 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F in replacement sub main wiring with 4 runs of 10 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 32 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 10 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Four run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S & F in repair for distribution board double door type, SPN, 12 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed. Make-Legrend/ Havells/ ABB
S & F in repair for distribution board double door type, SPN, 8 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed. Make-Legrend/ Havells/ ABB
S & F in repair MCCB 415 V, 125 Amps, 25 KA, 4 Pole complete all as specified and directed.Make -Legrend / ABB / Seimens
S & F in repair MCB TPN, 415 Volts, 63 Amps complete all as specified and directed. Make-Legrend / Havells/ Seimens
S & F in repair MCB DP, 240 Volts, 40 Amps complete all as specified and directed. Make-Legrend / Havells / Seimens
S & F in repair MCB DP, 240 Volts, 63 Amps complete all as specified and directed. Make-Legrend / Havells / Seimens
S & F in repair MCB SP, 240 Volts, 16 Amps complete all as specified and directed. Make-Legrend / Havells / Seimens
S & F in repair MCB SP, 240 Volts, 32Amps complete all as specified and directed. Make-Legrend / Havells / Seimens
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, checknuts and washers of galvanized iron or steel as shown in electrical plate No 3 connected to earthing test point including testing on completion all as directed. Note:- The unit rate quoted shall be include for necessary excavation and earth work , earth strip connected to test point max 7 mtr as per site requirement, PCC 1:3:6 type for earth pit & Pit cover, funnel with wire mesh including GI medium grade watering pipe 15mm bore & 25 mm dia for supporting of earth strip/wire.
Supply, fixing and connecting in replacement recessed mounting back- lit LED 2X2, 36 watt tile in CRCA housing with full opal diffuser suitable for Armstrong/ Grid Ceilings Type, size 595X595mm (Nominal),High lumen efficacy LED with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection minimum 2.5KV, safety & performance test as per IS:15885 Total system Lumen not less than 3600, in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80 with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed. Make : ORIENT Model No :- LTRAQ-36-C-VO/ Philps/ wipro
Supply, fixing and connecting in replacement of Slim LED Batten 20 watt with Surface/Wall Mounted integrated LED 4 feet Fitting Aluminium housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . Total system Lumen of 20W Led should be 2000 or above in Cool day Light(6500K), Power factor>0.9, CRI (Ra) >80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed.Make : ORIENT Model No :- LBLN-20-C-AL/ Philps/ wipro
S & F in repair motor for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions).
S & F in repair controller for Automatic operated Hermettically sealed Sliding doorsliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair power supply for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed.(Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair fotocell for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair side pully for sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair Belt for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair foot switch for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair hand senser for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair door lever handle for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair guide roller for sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair door cover strip for Automatic operated Hermettically sealed Sliding complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair end stoper for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair end stoper plate for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair wheel for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair wheel chair bkt for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair track for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair Canopy for track Automatic operated Hermettically sealed Sliding doorcomplete all as specified and as directed. (Make: MHS (Modular Healthcare System) Alanta Door Pvt Ltd/ Morfex Medi Solutions)
S & F in repair gasket for Automatic operated Hermettically sealed Sliding door complete all as specified and as directed.
S& F in repair Bedside Light 7 Watt, 400 lumens - 3000k , separate on/off switches, shade material aluminium with white powder coating, finish colour white, adjustable head for better beam and focus standard complete all as specified and as directed. Make - Philips.
SANJEEV ENTERPRISES
Saini Enterprises
RUCHIKA ENGG.WORKS
tarun construction co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .