| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC H O PRABHAT KUMAR SINHA RAGHUNATH TOLA ANISABAD PATNA 800002 | PATNA | PATNA | BIHAR | 800002 | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹16.3 L+₹3.1 L (23.6%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹17.0 L+₹3.9 L (29.3%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L3 | Rejected-Finance Being not lowest |
Tender Value
₹13.3 L
EMD Value
₹27,000
Closing Date
17 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAMRAULI
HQ CWE AF BAMRAULI ALLAHABAD-211012
PROVISION OF THREE PHASE POWER SUPPLY FOR TRANSPORTABLE SRE AT BIHTA
2020_MES_371104_2
87097/C/E8
Open Tender
Civil Works
Item Rate
182 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹27,000
Yes
4 Nov 2020
3 Oct 2020
19 Oct 2020
3 Oct 2020
17 Oct 2020
3 Oct 2020
60 days
Amount
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Excavating in post holes each not exceeding 0.5 Cum in soft/loose soil , getting out, and removing surplus soil to a distance not exceeding 50 metre and making good surface complete all as specified and directed. Note :- PCC for filling shall be measured and paid for separately under respective item of this schedule.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Material and labour for Hard core of broken bricks of guage not exceeding 63mm, deposited, spread and levelling in layers not exceeding 15 cm thick, watered and rammed to true surface complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Supply and spreading clean and dry screened sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed by Garrison Engineer/ Engr-in-Charge. Note:- Thickness for sand shall be measured after punning down.
Material and labour for providing PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concrete of pole pit complete all as specified and directed by Garrison Engineer/ Engr-in-Charge. Note :- Volume of pole shall deducted for payment purpose.
Material and labour for PCC 1:3:6, type C-2 ( using 40 mm graded stone aggregate ) as in mass concrete, foundation of stay assembly/post complete all as specified and as directed.
Supply and laying sub class 'B' bricks (Old Size) laid flat in trenches as cable covers abutting each other, gap between adjacent brick shall not be more than 10mm complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Material and labour for 50mm thick plain cement concrete, (1:2:4) type B-1,(using 20mm graded crushed stone aggregate, laid in bays, surface finished even a smooth without using extra cement complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Material and labour for chain link fencing 3.15mm dia GI wire 50 x 50mm mesh to angle iron post including provn of binding wire etc complete all as specified and directed by Garrison Engineer/ Engr-in-Charge. Note :- (i) Angle iron post, fillet and bolts for fixing chain link shall be measured and paid for separately under repective item of this schedule. (ii) Weight of chain link fencing shall not be less than 2.93. Kg per square metre.
Material and labour for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Supply, laying & testing cross linked polyethylene insulated (XLPE) galvanised steel strip armoured cable with aluminum conductor, 11 KV `E’, of cross sectional area 95 Sqmm, three core (IS-7098) in trenches/through pipes/ducts or on poles at crossing of OH lines of MES and road crossing complete all as specified and directed by Garrison Engineer/ Engr-in-Charge. Note :- Cable protection cover, cable joint, sand cushioning shall be measured and paid for separately under respective item of this schedule. .
Material and labour Danger notice plate for HT 25cmx20cmx1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts complete complete all as specified and directed by Garrison Engineer/ Engr-in-Charge. Note :- M.S Clamp, nut and bolts shall be deemed to include in quoted rates.
Material and labour for cable jointing kit for 11 KV (earthed) heat shrinkable, cable end termination, outdoor suitable for sizes of XLPE cable 75 to 95 sqmm, 3 core, aluminium conductor XLPE cable complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Material and labour for cable jointing kit for 11 KV (earthed) heat shrinkable, cable end termination, indoor suitable for sizes of XLPE cable 75 to 95 sqmm, 3 core, aluminium conductor XLPE cable complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, CI frame and charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment as specified and directed& testing on completion. NOTES : (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle including provision of MS angle of size 50x50x6mm thick all around earth pit cover and painting with syenthetic enamel paint all as specified and directed by Engineer in charge. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order (iii) Items includes cost of 7.5 metre earth lead strip. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by using 32x6mm thick galvanised iron strip complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.
Supply installation, testing and commissioning of step down transformer out door type complete with standard fittings and accessories, HT 11 KV 3 Phase, LT 433 Volt, 3 Phase 4 wire with off load tap changer on primary side to carry secondary voltage + 7 1/2% to - 7 1/2% with tappings at every 2 1/2% all as per IS 1180-2014 level 1 of capacity 160 KVA, copper wound, oil cooling with fins vector group: DYN 11, including initial oil filling complete all as specified including the following accessories :- (a) Three Nos porcelain bushing HT 11 KV with brass bushing rods, nuts, bolts & washers etc inside cable end box. (b) One cable box LV side consisting of 4 Nos porcelain with brass bushing rods complete with nuts and washers suitable for runs of 3.5 core LT UG Cable. (c) Oil conservator with filler type drain valve and oil level guage. (d) Dheydrating breather with fast fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover. (g) One No 100mm dia, dial type thermometer vapour pressure type having range 0 to 120 degree centigrade. (h) Rating plate and terminal marking platge. (j) Earthing arrangement. (k) Oil level gauge. (l) Oil drain filter valve. (m) Oil drain valve. (n) Lifting hook. (o) Oil conservator with filling hole and cap. (p) Air relief valve plug. (q) Four plate solid cast steel detachable rollers. (r) Earth bushing for neutral outside the cable box for providing independent earthing for neutral. (s) Necessary channel on foundation for fixing the transformer with joint and stopper.
Supply installation, testing and commissioning of 12 KV 3 phase, 630 Amps, 50 HZ, 25 KA outdoor fixed type floor mounted manually operated LOAD BREAK SWITCH totally enclosed metal clad switch gear complete including provn of 1 x incoming and 1 x outgoing for 160KVA transformer. The panel shall be made of inside welded stainless steel tank of minimum thickness 3.05mm having IP 67 degree of protection enhanced BIL of 75 kvp internally to manage voltage surge and internal copper bus bar as well as earthing bus bar of electrolytic grade copper, padlock provision and complete with all accessories. The panel shall be type tested for internal arc test of AFL 20KA/1 sec as per IEC62271-200. The earthing bus bar shall be provided inside cable compartment for solid earthing of cable sheilds. The outer hinged maindoor should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following necessary fittings as required at site:- (a) Incoming/Outgoing load break switch module. (b) The switch gear unit shall be designed as a three position switch. The three function switch combines the function of switch disconnector and earth switch.(c) 11KV, 630A load break switch module and interlocked line earthing switch, both with full making capacity-01 Nos (d) Short time current 20KA/3sec (e) Auxilary Contact-01 No + 1NC-01No (f) Spring assisted snap-action mechanism driver via shaft that remains un-inhibited after motorsation, if required in future-01 No (g) Cable boxes with door arrangement for enhanced safety (IP-54+IP5X) interlocked to prevent access upto 3core x 95Sqmm XLPE aluminium cable termination in live condition-Set of 1 (h) Right angle boots (push on type) each set of 3-01 No (j) Arc proof cable covers having cable entry from bottom front with interlocking mechanism including earth switch-01 No
M/s M A Traders
M/S VIJAY SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .