Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-Finance H NO 1135 VOLVOLEN TIVIM BARDEZ GOA 403502 | TIVIM | BARDEZ | GOA | 403502 | ₹13.6 L | L1 | Accepted-Finance L1 |
| 2 | L2₹13.9 LRejected-Finance | ₹13.9 L | L2 | Rejected-Finance L2 |
Tender Value
₹13.0 L
EMD Value
₹25,935
Closing Date
5 Dec 2025, 5:00 pmClosed
EXECUTIVE ENGINEER, DIVN V, BICHOILM.
O/O EXECUTIVE ENGINEER, DIVN V, BICHOLIM.
Tender for the Work of enhancement of DTC at Chinchbhatwadi, Mayem, and extension of LT line at various places for A.P.S. to 1no. LTAG and 9nos. LTD connections in the jurisdiction of SO Mayem, Sub Divn I, Bicholim
2025_ED_26675_1
Tender-45/Div-V (2025-26) (Re Tender)
Open Tender
Electrical Works
90 days
Bicholim
AS PER NIT SPECIFICATION
2 documents required · 2 mandatory
₹500
₹25,935
23 Jan 2026
27 Nov 2025
8 Dec 2025
28 Nov 2025
5 Dec 2025
1 Dec 2025
Cost of Material
Cement Concrete
HDG Nut bolts
HDGI DP structural Material
200KVA,11/0.433KV, distribution Transformer,level II losses,Alluminium Winding, with bimetallic terminal connectors, Energy efficiency level-II as per IS :- 1180(part-I)2014
M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse
XLPE Single Core unarmoured 300 sq.mm XLPE,1.1 KV grade cable
XLPE Single Core unarmoured 120 sq.mm XLPE,1.1 KV grade cable
Compression type Aluminium Lugs 300 sq.mm
GI Tubular Fencing complete with gate and side dismantling system as per the specification for Distribution Transformer and Feeder Pillars ( Size 4M x3M x2 M)with concreting for GI fencing supports with plinth (0.3 X 0.3x 0.5) cum.m. x 12 nos. each ratio 1:3:6 and brick masonary. (Galvanising should be hot dipped Galvanised as per 18.2629/66, minimum Zinc coating of 100 gms/sq.mtr,140 Microns DFT, Suitable for high Salinity coastal areas)
Enameled Danger boards 11000volts
Anticlimbing device along with suitable two pair stay clamps & two pairs of Hdgi nut bolts
ACSR "Racoon Conductor for three phases
ACSR 'Weasel' conductor for Earthing & guardings
AA ANT conductor
AA GNAT Conductor
Cost of Erection
HDG Nut bolts
200KVA,11/0.433KV, distribution Transformer,level II losses,Alluminium Winding, with bimetallic terminal connectors, Energy efficiency level-II as per IS :- 1180(part-I)2014
M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse
XLPE Single Core unarmoured 300 sq.mm XLPE,1.1 KV grade cable
XLPE Single Core unarmoured 120 sq.mm XLPE,1.1 KV grade cable
Compression type Aluminium Lugs 300 sq.mm
GI Tubular Fencing complete with gate and side dismantling system as per the specification for Distribution Transformer and Feeder Pillars ( Size 4M x3M x2 M)with concreting for GI fencing supports with plinth (0.3 X 0.3x 0.5) cum.m. x 12 nos. each ratio 1:3:6 and brick masonary. (Galvanising should be hot dipped Galvanised as per 18.2629/66, minimum Zinc coating of 100 gms/sq.mtr,140 Microns DFT, Suitable for high Salinity coastal areas)
Anticlimbing device along with suitable two pair stay clamps & two pairs of Hdgi nut bolts
ACSR "Racoon Conductor for three phases
ACSR 'Weasel' conductor for Earthing & guardings
AA ANT conductor
AA GNAT Conductor
Removing of structural material
Removing of 100KVA Distribution transformer
Removing of M.S. Distribution Box With 400Amps MCCB and Kit-Kat Fuse
Removing of 3.5 core 240 sq.mm Xlpe insulated armoured cable
Removing of 3.5 core Xlpe insulated Armoured cable, 1.1 KV grade, 70sq.mm
Cost of Material
HDGI Nuts & Bolts
Erection of LT pin Insulator with
Turn buckle with eye bolt 11KV/LT
Stay wire 7/10
Erection of HDG LT 2 pin X-arm channel type 75x40 Channel
Erection of HDG X-arm clamps for 9.0 mtrs RCC pole L.A/S.A. type
HDGI Stay Clamps for RCC pole 9.0 mtr L.A/S.A. type
RCC poles 9 mtr long as per Drawing CEE/C-836
Earthing complete with 40mm GI Pipe, 2.5 mts long along with 20 Kgs each salt, charcoal complete
ACSR conductor 'WEASEL' 6+1/2.59 mm nominal aluminium area 30mm2 (139 amps max. at 45° C)
4core XLPE armoured cable, 1.1 KV grade 16 sq.mm
Supply & Fixing of LT distribution box/kiosk on LT pole including all clamps & material required for mounting, connections & sealing
Supply & Laying of GI Pipe 50mm, class B
Supply and laying of U/G cable protective cover of size 480mm long x 250mm width and 50mm casted by confined mold vibratory cast of concrete ix M30, having strength of 30N/mm2 at 28 days.
Supply & Erection of Warning tape.
Laterite Masonary works (Rubble packing with hard laterite stone under floors including watering ramming and consolidating. Etc. in pipeline trenches and other foundation completes for ( f) multi circuit LT and service cable trenche ( 0.2 x 0.4 x50 mtr)
Cost of Erection
HDGI Nuts & Bolts
Erection of 7.5 mtr RCC pole
Erection of HDG LT 4 pin X-arm channel type 75X40 Channel
Erection of LT Shackle Insulator
HDGI Metal parts of LT shackle Insulator
Stay rod with Plate
Turn buckle with eye bolt 11KV/LT
Stay wire 7/10
Supply & Stringing of A.A. 'ANT' conductor
Supply & Stringing of A.A. 'GNAT conductor
Erection of HDG LT 2 pin X-arm channel type 75x40 Channel
Removing & Re-Stringing of A.A. 'ANT' conductor
Removing & Re-Stringing of A.A. 'GNAT' conductor
RCC poles 9 mtr long as per Drawing CEE/C-836
Earthing complete with 40mm GI Pipe, 2.5 mts long along with 20 Kgs each salt, charcoal complete
ACSR conductor 'WEASEL' 6+1/2.59 mm nominal aluminium area 30mm2 (139 amps max. at 45° C)
4core XLPE armoured cable, 1.1 KV grade 16 sq.mm
Supply & Fixing of LT distribution box/kiosk on LT pole including all clamps & material required for mounting, connections & sealing
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : b) All types of Ordinary rock including all types of laterite rock, where blasting prohibited.(0.9 x 0.4 x 50 mtr)
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.( Deduct for RCC slab)(0.7 x 0.4x 50mtr)
Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. a) Sand ( after deducting for LT cable & brick)( 0.15 x 0.4 x 30mtr)
Supply and laying of U/G cable protective cover of size 480mm long x 250mm width and 50mm casted by confined mold vibratory cast of concrete ix M30, having strength of 30N/mm2 at 28 days.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 24.29 MB
BOQ_27116.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid