| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹35.7 L+₹9.8 L (37.9%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹1.1 Cr+₹79.3 L (306.3%)Rejected-AOC 213 F BLOCK MEGA MARGANPATTE HADAPSAR PUNE 411013 | PUNE | MAHARASHTRA | 411013 | L3 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (N) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Maintenance and cleaning of sewage line including central sewage system, chambers, septic tank and man holes, soakage pits etc under AGE BR II at GE (N) Ahmednagar
2021_MES_440992_1
8527/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (N) Ahmednagar
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹60,000
Yes
26 Jun 2021
6 May 2021
21 Jun 2021
6 May 2021
19 Jun 2021
21 May 2021
60 days
Amount
Demolition of cement concrete (un-reinforced) in ground floor & paving n.exc. 15cm thick below or above ground level etc complete all as specified and directed by Engr-in-Charge.
Surface dressing n exc 15 cm deep and removal of wild growth / shrubs, roots, incl spraying of deweeding chemical 1 m wide on each side, along sewage line etc complete all as specified and directed by Engineer-in-Charge Note:- (i) Payment for removal of wild growth shall be made once upto completion of subject work. (ii) Contractor shall be responsable to keep the site clean upto completion of the work and no payment shall be allowed after words for the stretch paid in above item.
Excavation in treanches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells exc 10 sqm on plan and getting out in hard/dense soil etc complete all as specified and directed by Engineer-in-Charge
All as per item No 3 (here-in-before) but depth exc 1.50 m and not exc 3.00 m.
Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil etc complete all as specified and directed by Engineer-in-Charge
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
M & L for plain Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed by Engineer-in-Charge
M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in surface channels, drain and similar works etc complete all as specified and directed by Engineer-in-Charge
M & L for pre-cast cement concrete solid blocks, exc. 10 cm in width type D-1 (1:5:10) using 20 mm graded stone aggregates and setting in cement and sand mortar 1:6 including demolition etc complete all as specified and directed by Engr-in-Charge
M&L for rendering, 15 mm thick on stone/brick / concrete surfaces in cement and sand mortar (1:4) finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed by Engr-in-Charge.
S&F 110 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engr-in-Charge
M&L for rendering, 10 mm thick on brick / concrete surfaces in cement and sand mortar 1:6 surfaces finished even and smooth without using extra cement including taking down cement mortar plaster on brick or stone walls, raking out joints, hacking for key complete all as directed by Engr-in-Charge
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
Material and labour for 60 mm thick, PCC pavers interlocking tiles of glossy finish, with grey cement and no pigment ,any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made over and incl 30mm thick sand cushioning and joints filled with fine sand incl leveled with plate vibrator & sweeping etc complete all as specified and directed by Engr-in-Charge.
M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors with grey cement and pigment, machine pressed, factory made, set, jointed and pointed in neat cement slurry in floors over and including screed bed 15mm thick in cement and sand mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M& L for 40 mm thick rough dressed Shahabad stone as in floor etc over and incl 15 mm thick screed base in cement and sand mortar (1:6) and pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engr-in-Charge.
M/L for providing 75mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base etc complete all as specified and directed by Engr-in-Charge
M&L for 100 mm thick PCC type B- 2, using 40 mm graded stone aggregate as in hard standing complete all as specified and directed by Engr-in-Charge.
M/L for providing 75mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection etc complete all as specified and directed by Engr-in-Charge
Material and labour for 100 mm bore SGSW drain pipe grade 'A' laid in trenches and jointed as specified including cement concrete bed to pipe including packing under and hauching against the sides of pipe in PCC (1:4:8) type D-2 using 40 mm graded mechanically crushed stone aggregates,, making necessary connections after cutting into existing sewer line /manhole to make it functional after taking down/out salt glazed ware, AC or reinforced concrete pipe as existing at site etc complete all as specified and directed by Engineer-in-Charge
Material and labour for 150mm bore Reinforced cement concrete pipe, type NP-2 with & including cement concrete bed to pipe including packing under and hauching against the sides of pipe in PCC (1:4:8) type D-2 using 40 mm graded mechanically crushed stone aggregates, making necessary connections after cutting into existing sewer line /manhole to make it functional after taking down/out salt glazed ware, AC or reinforced concrete pipe as existing at site complete all as specified and directed.
All as per item No 22 (here-in-before) but 200mm bore pipe
All as per serial item No 22 above but 300mm dia RCC pipe Note for item No 21 to 24 : Cutting into existing sewer line / manhole, excavation and earth work shall be measured & paid for separately.
Cutting into existing manhole for connecting new drain 100 mm internal dia of pipe making good to pipe and rendering cutting out existing benching for good forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 using graded stone aggregates, smooth finished and as required for 100mm internal dia pipe etc complete all as specified and directed by Engineer-in-Charge
All as per item No 25 (here-in-before) but for 150mm internal dia of pipe.
All as per item No 25 (here-in-before) but for 200mm internal dia of pipe.
All as per item No 25 (here-in-before) but for 300mm internal dia of pipe.
Supplying and fixing precast manhole cover (LD) of size 12" x 12" made up of steel fibre reinforced concrete M-30 grade as per IS etc complete all as specified and directed by Engineer-in-Charge Note : Make and material shall be as approved by GE.
All as per item No 29 (here-in-before) but of size 18" x 36" etc.
All as per item No 29 (here-in-before) but of size 24" x 36" etc.
Supply and fixing precast Hume Pipe septic tank of capacity 10 users including necessary excavation and earthwork in any type of strata etc complete all as specified and directed by Engineer-in-Charge Note : (i) Septic tank shall be kept minimum 15 cm below GL and shall be laid according to slope of sewage line. (ii) Make and material shall be as approved by GE.
All as per item No 32 (here-in-before) but septic tank of capacity 25 users.
All as per item No 32 (here-in-before) but septic tank of capacity 50 users.
Cleaning of sewage pipe line (RCC / SGSW) by mechanical means such as Rottary cutter etc incl removal of roots inside the pipe etc, including rodding manually or mechanically from manhole to manhole and removing the waste materials / sludge disposing to a distance n exc 50 m and burying in borrow pits and covering with mud all as directed of any diameter of pipe etc complete all as specified and directed by Engineer-in-Charge Note:- (i) Contractor shall take all Precantionery measures during cleaning of sewage line / septic tanks etc. (ii) Contractor shall provide First Aid box, shoes, hand gloves, mask & required clothing to the workers at site. (iii) It shall be the responsibility of Contractor that if any mishap happens at site, Govt shall not be liable to pay any type of compensation.
Cleaning/desludging of existing septic tank of any capacity/sump well of any dia and depth incl taking out sludge in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots or vegetation etc by means of sewage sucking machine or by way of any other suitable means and removing the sludge outside MD land by any means including writing the date of cleaning with white paint on black background of size 150x200 mm etc complete all as specified and directed by Engineer-in-Charge Note:- Volume of water will not be measured for the purpose of payment.
S&F in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistern etc complete all as specified and directed by Engineer-in-Charge. Make :- Cat Part No C0117 of Parryware or Cat Part No 20042 of Hindware or equivalent make as per list of makes mentioned in appendix `C
S&F in repairs vitreous china wash down water closet (Pedestal pattern) white including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom and cover and MSCP almn hinges device etc complete all as specified and directed by Engineer-in-Charge connecting to 'P' or 'S' trap etc complete all as specified and directed by Engineer-in-Charge. Make:-Petite series Cat part No C0287(S)/88(P) Incl seat cover Cat part No E8309 of Parry ware or equivalent make as per list of makes mentioned in appendix `C
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engr-in-Charge.
S&F of 75 mm bore PVC (SWR) bends with access door etc complete all as specified and directed by Engr-in-Charge.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed by Engr-in-Charge.
NOTE : (i) The contractor / his supervisor will report to the office of AGE B/R II at 0900 hrs in the morning every day to collect the complaint slip from JE. In case the contractor / his supervisor failed to report the office of AGE B/R II at 0900 hrs in the morning for collection of complaint slip from JE, an amount of Rs 1000.00 per day will be charged as an penalty and the same will be recovered from contractor's due payments. (ii) The contractor and his supervisor will provide mobile numbers to AGE B/R II so that they can be communicated about the complaint. The SMS will be sent on those mobile numbers and will be treated as an official complaints. The contractor will render the completion of each complaint in writing to the department within 24 hrs failing which an amount of Rs 500 per day per complaint will be charged as penalty and same will be recovered from contract's due payment.
An amount of Rs 36,000.00.00 shall be deducted from BOQ on account of schedule of credit
KAMINS CARE
Crown Chemicals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .