Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC 0 DHANA TEJA BARARI DHANA TEJA MATHURA MATHURA UTTAR PRADESH 281005 | MATHURA | UTTAR PRADESH | 281005 | ₹2.4 Cr | L1 | Accepted-AOC Work awarded |
| 2 | L2₹2.5 Cr+₹3.9 L (1.60%)Rejected-Finance 11A 2 PRATAP NAGAR WEST MAHOLI ROAD MATHURA UTTAR PRADESH 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | ₹2.5 Cr+₹3.9 L (1.60%) | L2 | Rejected-Finance L2 |
| 3 | L3₹2.6 Cr+₹16.5 L (6.78%)Rejected-Finance HN 11 SICHAI COLONY SARASWATI SCHOOL KE PICHE CHHATARPUR MADHYA PRADESH 471001 | CHHATARPUR | MADHYA PRADESH | 471001 | ₹2.6 Cr+₹16.5 L (6.78%) | L3 | Rejected-Finance L3 |
| 4 | L4₹3.1 Cr+₹69.3 L (28.5%)Rejected-Finance | ₹3.1 Cr+₹69.3 L (28.5%) | L4 | Rejected-Finance L4 |
| 5 | L5₹3.2 Cr+₹72.3 L (29.7%)Rejected-Finance 220 A P COLONY GAYA BIHAR 800023 | PATNA | BIHAR | 800023 | ₹3.2 Cr+₹72.3 L (29.7%) | L5 | Rejected-Finance L5 |
Tender Value
₹4.1 Cr
EMD Value
₹12.4 L
Closing Date
16 Apr 2025, 6:00 pmClosed
AGM (Engg-C)
AGM (Engg-C), Khajuraho Airport, Khajuraho (MP)
Construction of RCC Drain Boundary wall and associated civil works for new site of DVOR at Khajuraho Airport Khajuraho.
2025_AAI_229282_1
AAI/Khj/Engg-C/B-wall/ RCC Drain/2024-25
Open Tender
Civil Works
Item Rate
180 days
Khajuraho Airport
Please refer Tender documents.
31 documents required · 31 mandatory
₹1,180
₹12.4 L
Khajuraho Airport
15 Jul 2025
26 Mar 2025
18 Apr 2025
27 Mar 2025
16 Apr 2025
10 Apr 2025
27 Mar 2025 - 3 Apr 2025
2 Apr 2025
Amount
Civil works
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. a) In cement mortar.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, within AAI premises in (low lying areas), for all leads including all lifts involved.
Credit for taking away Serviceable bricks outside AAI premises as per direction of Engineer In charge.
Credit for taking away Serviceable brick bats/broken bricks outside AAI premises as per direction of Engineer In charge
Excavation in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead within airport premises and as per satisfaction and direction of Engineer-In-Charge.
Excavation in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site within all lifts and lead within Airport premises, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections, etc complete as per direction of Engineer-In-Charge.
Excavation in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal within all lifts and lead upto Within Airport premises, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections etc complete as per direction of Engineer-In-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. a) All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. a) Ordinary rock
Filling Available excavated earth in anywhere inside airport premises in operational/non-operational area As per the direction of E-I-C including all leads / lifts & transportation etc. complete in embankment or depressions in accordance with requirements of lines , grades and in cross section in layers not exceeding 20cm in depth consolidating each deposit layer by watering and ramming and every third top most layer with 8-10 tonne vibratory roller/ soil compactor etc complete as per direction and satisfaction of Engineer-In-charge. (Note : Payment to be made for compacted quantity only.)
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources :10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :- a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-II) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : a) Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights : a) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : a) Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : a) Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. a) All works upto plinth level - Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. a) All works above plinth level upto floor V level - Concrete of M25 grade with minimum cement content of 330 kg /cum
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement Mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
12 mm cement plaster of mix : a) 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : a) 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : a) 1:3 (1 cement : 3 fine sand)
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) Flush/ Ruled pointing
Finishing walls with water proofing cement paint of required shade : a) New work (Two or more coats applied @ 3.84 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : a) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. bituminous road
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately).
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. a) 900 mm dia RCC pipes.
G. R. Engineers and Contractor (BID ID -840443)
SANWARIYA CONSTRUCTION (BID ID -840956)
S G CONSTRUCTIONS (BID ID -841536)
M/s Awadhesh Construction (BID ID -839960)
trisira construction pvt ltd (BID ID -841518)
M/s HYDRO INDIA PROJECTS (BID ID -841686)
AJAY PAL SINGH (BID ID -841687)
chid infra india (BID ID -841764)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.pdf
Tender Documents • 20.42 MB
BOQ.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .