₹71.6 L
EMD Value
₹1.4 L
Closing Date
22 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
POWER/BCT
22 conditions · 7 needing a document upload
Financial Eligibility Criteria - The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure - VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. (Page- 14, Para 10.2, Part-I of GCC April 2022). Attached Performa as per Annexure VIB - in Tender Document).
Electrical Contractor License: The tendering firm must have valid Electrical Contractor's License issued by any State Government in their own name or in the name of the firm, as per IE Rule 1956 clause No. 45 or as amended from time to time. A copy of the license shall be uploaded along with the tender offer failing which the offer shall be summarily rejected. The license must be valid as on the date of opening of the tender. If the license has been expired as on the date of opening of tender, the license renewal documents must be uploaded along with the copy of the old license. The Contractor shall possess valid License throughout the currency of the contract. The contractor shall ensure timely renewal of the license.
Similar Nature Work - "Wiring/Re-wiring in buildings with associated electrical works like control gear and protection arrangements in residential buildings or service buildings or railway stations /yards or colony/highway lightings. OR Lighting arrangement in buildings, circulating area, yard, street etc. with associated electrical woks. OR Wiring/Rewiring, Lighting arrangement in buildings with associated electrical works."
26 conditions · 9 needing a document upload
1) The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. 2) The Bid Security shall be deposited either in cash through e-payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. (3) In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days before closing date for submission of bids(ACS-2 Dated 13.12.2022) iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non-submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to the officer and address as mentioned in the tender document. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder. (As per Clause 5, Page -4,5,6 Part I GCC April 2022 with ACS-2 Dated 13.12.2022)
Subject to exemptions provided under para 5(1) (a) of Part-1 (ITT) of GCC April 2022, the tender must be accompanied by a Bid Security as mentioned in tender documents, failing which the tender shall be summarily rejected. (Clause 6 (a) Annex -I, Page-11, Part-I of GCC April 2022)
Note: i) Any firm recognized by Department of Industrial Policy and Promotion (DIPP as 'Startups' shall be exempted from payment of Bid Security subject to submission of Registration Certificate issued by appropriate authority. ii) Labour Cooperative Societies shall submit only 50% of Bid Security shall also additionally submit Registration Certificate. (As per Clause 5 , Page-5, Part-I of GCC April 2022)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer Credentials: Documents testifying tenderer previous experience and financial status should be produced along with the tender. (Clause 11, Page-16-17, Part-I of GCC April 2022)
(i) Certificates and testimonials regarding contracting experience for the type of job for which tender is invited with list of works carried out in the past.
(ii) Audited Balance Sheet duly certified by the Chartered Accountant regarding contractual payments received in the past. The documentary proof whether the Balance sheets of each year are audited or not must be submitted. Audited Balance sheet with UDIN shall be submitted to established authenticity of the submitted documents.
(iii) The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
(iv) A copy of certificate stating that they are not liable to be disqualified and all their statements / documents submitted along with bid are true and factual. Standard format of the certificate to be submitted by the bidder is enclosed as Annexure-V. Non submission of a copy of certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested / digitally signed by which they/he are/is qualifying the Qualifying Criteria mentioned in the Tender Document.
(v) The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway there under.
(vi) (a) In case of any information submitted by tenderer is found to be false, forged or incorrect at any time during process for evaluation of tenders, it shall lead to forfeiture of the tender Bid Security besides banning of business for a period of upto two years. (b) In case of any information submitted by tenderer is found to be false, forged or incorrect after the award of contract, the contract shall be terminated. Bid Security, Performance Guarantee and Security Deposit available with the railway shall be forfeited. In addition, other dues of the contractor, if any, under this contract shall be forfeited and agency shall be banned for doing business for a period of upto two years.
Non-compliance with any of the conditions set forth therein above is liable to result in the tender being rejected.
This tender complies with Public Procurement Policy (Make in India) Order, 2017 - Revision dated 16/09/2020, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2020/RS(G)/779/2/Pt.1 dated 25/09/2020 and amendments / revisions thereof." The full details of the order can be seen at http://dipp.nic.in/whats-new/publicprocurement- preference- make-india-order- 2017. (Authority Railway Boards L. No. 2020/RS(G)/779/2/Pt.1 dated 25-09- 2020)
Contractor is to abide by the provisions of various labour laws in terms of above clause 54, 55, 55-A and 55-B of the Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website ''www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/ company etc. and upload requisite details of labour and their payment in this portal. These details shall be available in public domain. (Page- 86-89, Part-II of GCC-April 2022)
Mumbai Central Division - Electrical (Power) work in connection with provision of sewage treatment plant (STP) of 50 KLD each at Palghar, Umbergaon Road and Boisar under the jurisdiction of ADEN -DRD.
EL-81-932-WA-63~WR
EL-81-932-WA-63
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹1.4 L
22 Jan 2026
23 Dec 2025
8 Jan 2026
109 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 71,55,522 | ||
| — | 150.00 | — | — | ||
| Supply of material and providing light/fan point concealed wiring, with single core multi-strand copper wire, PVC insulated unsheathed, LSHF / ZHFR, of size 1.5 sq.mm. for phase, neutral & earth wire and modular switches, complete with all accessories, junction box, ceiling rose etc, as per specifications in Annexure I. | — | — | — | 78,900 | |
| — | 885.00 | — | — | ||
| Supply of material and providing main/ submain concealed wiring, with single core multi-strand copper wire, PVC insulated unsheathed, LSHF / ZHFR, of size 4.0 sq.mm. for phase, neutral & earth wire, as per specifications in Annexure II. | — | — | — | 1,37,175 | |
| — | 9.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of six module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 1,296 | |
| — | 9.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of eight module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 1,611 | |
| — | 9.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of twelve module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 1,926 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing & commissioning of modular socket 3 pin of 10A capacity with 10A one way modular switch, as per specifications in Annexure IV. | — | — | — | 4,590 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing & commissioning of modular power socket 3 pin twin heavy duty of 10/20 A capacity with 20A one way modular switch having neon indicator, as per specifications in Annexure V. | — | — | — | 3,825 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing & commissioning of 63A 4P MCB with m.s. enclosure, as per specifications in Annexure VI. | — | — | — | 13,386 | |
| — | 6.00 | — | — | ||
| Supply, fixing & commissioning of MCB DB single phase with RCCB, I/C-DP MCB of 40A - 1No. & DP RCCB of 40A - 1No., O/G: SP MCB of 6A-32A - 8Nos, enclosure made of non metallic polycarbonate thermoplastic material, IP 65 weatherproof, as per specifications in Annexure VII. | — | — | — | 38,232 | |
| — | 6.00 | — | — | ||
| Supply, fixing & commissioning of MCB DB three phase, I/C: 4P MCB 63A - 02Nos., O/G: 4P MCB 32A- 05Nos., enclosure made of non metallic polycarbonate thermoplastic material, IP 65 weatherproof, as per specifications in Annexure VIII. | — | — | — | 1,04,082 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing & commissioning of 100A 4P RCBO with 100mA sensitivity, in m.s. enclosure, as per specifications in Annexure IX. | — | — | — | 48,072 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing & commissioning of energy efficient BEE 5 star rated BLDC ceiling fan 1200mm ( 4 8 " ) sweep with down rod, modular electronic regulator and standard accessories, fan & regulator shall be compatible to work with various makes & models, as per specifications in Annexure X. (Minimum Warrantee - 2 years) | — | — | — | 38,760 | |
| — | 9.00 | — | — | ||
| Supply, fixing, testing & commissioning of super energy efficient BLDC motor industrial exhaust fan of size 300mm (12") sweep and standard accessories, as per specifications in Annexure XI. (Minimum Warrantee - 2 years) | — | — | — | 50,112 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing & commissioning of wall bracket fan of size 16"/400mm sweep, 1350 rpm and BLDC motor, as per specifications in Annexure XII. (Minimum Warrantee - 2 years) | — | — | — | 66,015 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing and commissioning of air circulator wall mounting type fans of size 30"/750mm sweep complete with necessary fixing arrangement, as per specifications in Annexure XIII. | — | — | — | 1,51,980 | |
| — | 6.00 | — | — | ||
| Supply and providing Pedestal fan size 16"/400mm sweep, BLDC motor, with regulator as per specifications in Annexure XIV. (Minimum Warrantee - 2 years) | — | — | — | 26,394 | |
| — | 60.00 | — | — | ||
| Supply, fixing, testing & commissioning of indoor type LED luminaires 20W maximum, 4 ft long, System efficacy greater than or equal to 110 lm/W, Luminaires must be capable of delivering minimum 2000 lumens, luminaires complete with all accessories and other specifications as per Annexure XV. (Minimum Warrantee - 5 years) | — | — | — | 12,540 | |
| — | 18.00 | — | — | ||
| Supply, fixing, testing & commissioning of indoor type LED luminaires 40W maximum, 2'x2' size, recess mounting type, System efficacy greater than or equal to 100 lm/W, Luminaires must be capable of delivering minimum 3500 lumens, luminaires complete with all accessories and other specifications as per Annexure XV. (Minimum Warrantee - 5 years) | — | — | — | 25,686 | |
| — | 36.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED street light lumaires 45W (maximum 48W including driver), whether proof having IP 65/66 protection, having inbuilt auto dimming driver and sensor, System efficacy greater than or equal to 120 lm/W, Luminaires must be capable of delivering minimum 5400 lumens, luminaries complete with all accessories and other specifications as per Annexure XV. (Minimum Warrantee - 5 years) | — | — | — | 1,18,908 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED highbay luminaires, 102W (105 maximum), weather proof having IP 65 protection, System efficacy greater than or equal to 125 lm/W, Luminaires must be capable of delivering minimum 12500 lumens, luminaires complete with all accessories and other specifications as per Annexure XV. (Minimum Warrantee - 5 years) | — | — | — | 1,21,305 | |
| — | 60.00 | — | — | ||
| Survey, design, manufacture, display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 Micrometre thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Details as per specifications in Annexure XVI. | — | — | — | 1,31,160 | |
| — | 60.00 | — | — | ||
| Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 Micrometre thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. Details as per corresponding specifications in Annexure XVI. | — | — | — | 13,020 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of 125A, 4 pole electronic / microprocessor based MCCB, with inbuilt earth fault protection along with earth leakage protection having shunt coil, earth leakage relay 30mA -30A CBCT etc., in sheet steel enclosure, as per specifications in Annexure XVII. | — | — | — | 1,46,841 | |
| — | 3.00 | — | — | ||
| Design, fabrication, supply, erection, testing and commissioning of outdoor type 3 Phase LT distribution panel board comprising of the following switchgears/ accessories: Incoming - MCCB, 4-pole, 125 Amp, with thermal-magnetic release range 100 - 125 Amp, having 35 KA breaking capacity = 1 No. Outgoing - MCCB 4-pole, 63 Amp, with thermal magnetic release range 50 - 63 Amp, having 35 KA breaking capacity = 2 Nos., MCB TPN 32 Amp having 10 KA breaking capacity = 10 nos. MCB DP 10 Amp having 10 KA breaking capacity = 4 nos. Panel shall be complete with copper busbar, spreader terminals, handle, meters, indication lamps & other accessories, as per specifications in Annexure XVIII. | — | — | — | 2,90,640 | |
| — | 9.00 | — | — | ||
| Provision of new fire extinguishers, 6 KG DCP type, as per specifications in Annexure XIX. | — | — | — | 11,943 | |
| — | 9.00 | — | — | ||
| Provision of new fire extinguishers, 4.5 KG CO2 type, as per specifications in Annexure XX. | — | — | — | 22,932 | |
| — | 1500.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded copper conductor cable of size 16 sq.mm.x 4 core, as per specifications in Annexure XXI. | — | — | — | 20,71,500 | |
| — | 32.00 | — | — | ||
| Supply, fixing, testing & commissioning of heavy duty copper lugs of size 16 sq.mm. for cable termination, as per specifications in Annexure XXII. | — | — | — | 576 | |
| — | 300.00 | — | — | ||
| Excavation of the cable trench in normal soil under rail/ road and refilling back the excavated earth, restoring /repairing of flooring after lying of cable, as per specifications in Annexure XXIII. | — | — | — | 27,600 | |
| — | 200.00 | — | — | ||
| Excavation of the cable trench in hard soil under rail/ road/rocky soil / platforms (stone/RCC/Rock) and refilling back the excavated earth, recasting of flooring after lying of cable, as per specifications in Annexure XXIV. | — | — | — | 1,24,800 | |
| — | 500.00 | — | — | ||
| Supply and laying of RCC truncking in trenches and supply and laying of capping on cable laid in trucking, size 150 mm, as per specifications in Annexure XXV. | — | — | — | 1,74,000 | |
| — | 999.00 | — | — | ||
| Supply of material & saddling to the cables with GI saddles, as per specifications in Annexure XXVI. | — | — | — | 47,952 | |
| — | 30.00 | — | — | ||
| Supply, fixing & commissioning of cable looping junction box, weatherproof for single phase, made of glass fiber reinforced polyester GRP moulding composite material, of minimum size 200mm x 140mm x 95mm (inside dimensions) with Kitkat fuse, as per specifications in Annexure XXVII. | — | — | — | 13,860 | |
| — | 18.00 | — | — | ||
| Design, fabrication, transportation, supply & erection of 4 meter length hot dip galvanized iron sheet street light octagonal pole with foundation type base plate & foundation bolts, excluding foundation (Approximate Dimensions for pole: Top Diameter greater than or equal to 70 mm, Bottom Diameter 130 mm, Section Length- 5000 mm, Thickness-3 mm, Foundation Type Base Plate (200X200X12 mm), Foundation Bolts (M16 X 600MM 4Nos).with two arm brackets min. 1000 mm long, suitable for LED street light fitting, as per specifications in Annexure XXVIII. | — | — | — | 2,07,990 | |
| — | 18.00 | — | — | ||
| Design, supply of material & casting of RCC foundation with 1:3:6 concrete suitable for 4 meter high GI street light octagonal pole, as per specifications in Annexure XXIX. | — | — | — | 36,270 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of digital astronomical daily time switch as per Legrand DX3/ AlphaRex3 or similar, with 25A 4NO contactor as per Legrand cat. No. 4125 51 or similar & 06 module cabinet IP65 as per Legrand Cat. No. 6019 96 or similar, complete with internal wiring & connections, fixing arrangement, as per specifications in Annexure XXX. | — | — | — | 16,566 | |
| — | 18.00 | — | — | ||
| Supply of material & providing earthing with 'B' class G I pipe 3M long x 50mm dia, 3.2mm thick ISI marked, with earthing chamber & top cover, as per specifications in Annexure XXXI. | — | — | — | 58,410 | |
| — | 6.00 | — | — | ||
| Supply of material & installation of maintenance free earth electrode of length 3 meter, including earth enhancement material for earthing for each electrode & other accessories as per Drg. No. SDO/ RDSO/ E&B/001 and RDSO Spec No. RDSO/SPN/197 /2008, as per Annexure XXXII. | — | — | — | 67,146 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing & commissioning of G.I. strip 25mm x 6mm for earthing, including cutting, bending, welding, excavation etc., as per specifications in Annexure XXXIII. | — | — | — | 10,400 | |
| — | 3.00 | — | — | ||
| Supply and fixing G.I. strip hot dip galvanized of size 50mm x 6mm for main earthing terminal MET with total length including all bends etc. minimum 2 ft.. Scope also includes cutting, bending, welding, excavation etc. Specifications in Annexure XXXIV. | — | — | — | 2,016 | |
| — | 75.00 | — | — | ||
| Supply, laying, testing, fixing and commissioning of PVC insulated & PVC sheathed, multi-stranded, 1.1 KV grade, copper conductor cable of size 16 sq.mm. single core FRLS, in flexible / rigid PVC conduit, complete with clamping of the cables, and lugs at each connection, as per specifications in Annexure XXXV. | — | — | — | 15,675 | |
| — | 500.00 | — | — | ||
| Supply and fixing of GRP / FRP cable tray made of glass fiber reinforced polyester moulding composite material, size 200mm width x 50mm depth min., 04mm thick min., including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders etc., as per specifications in Annexure XXXVI. | — | — | — | 4,01,500 | |
| — | 3.00 | — | — | ||
| Supply of aluminum ladder of size 6 feet height (when open), double sided, made from aluminum section of minimum size - 66 x 31 x 3.15 mm thickness, 5 steps of 1 ft. width min., two way climbing, Top platform min. size 10" x 14", complete with anti-skid solid rubber at bottom, as per specifications in Annexure XXXVII. | — | — | — | 31,776 | |
| — | 3.00 | — | — | ||
| Supply of aluminum folding ladder of size 10 feet height (when open), double sided, made from aluminum section of minimum size - 66 x 31 x 3.15 mm thickness, 9 steps of 1 ft. width min., two way climbing, Top platform min. size 12" x 16", complete with anti-skid solid rubber at bottom, as per specifications in Annexure XXXVIII. | — | — | — | 52,989 | |
| — | 3.00 | — | — | ||
| Supply of hammer type drill machine, heavy duty, 230V, 50Hzs, complete with auxiliary handle, accessory set, Accepted make - Bosch GBH 220 SDS Plus Professional Rotary Hammer or similar of Stanley / Dewalt / Hitachi Rotary Hammer Drill. | — | — | — | 19,359 | |
| — | 3.00 | — | — | ||
| Supply of Digital Earth resistance meter with Testing Kit. Display : 3½ or 4 Digit LCD display 2000 count, Data hold facility, Earth resistance measurement range from 0 - 01ohm to 2000ohm, Power Source - Battery Powered, Maximum Operating Voltage - 30V, Measurement Type - Ohmmeter. Complete with accessories like Test leads/ set of 3 spikes (stake) and connecting wires, carrying case, battery, instructions manual etc. KM 1520 model of Kusum MECO make or similar of FLUKE, RISHABH, MEGGER, MITRAVI. | — | — | — | 47,790 | |
| — | 3.00 | — | — | ||
| Supply of Digital Clamp Meter with following specifications: 3 ½ digits, LCD display, 2000 counts with automatic sign & function, 5 functions, Battery check function, Low battery indication, Overload protection, Audible continuity, Average Sensing, Over Range Indication, Diode Test, AC Current- 0.01 Amp, AC Voltage- 0.1V -750V DC Voltage- 1.0MV-1000V, Resistance- 0.1 Ohms-2000K Ohms, Power supply- Single standard 9V Battery. Make- KUSUM-MECO KM 2700, FLUKE 362, RISHABH RISH 1000 AAC, MEGGER-DCM-310/EN, MITRAVI-DT-4250. | — | — | — | 13,641 | |
| — | 3.00 | — | — | ||
| Supply of Smart Thermal camera / Thermal imager having infrared resolution - 256 x 192 pixels or more, with Super Resolution 240 x 240 pixels, Temperature Range: -20°C to 400°C (- 4°F to 752°F), with wireless LAN module, USB cable, mains unit, Data Storage -Built-in 16 GB flash memory with image and video storage capacity of 60,000 images, Battery Life: Approx. 4 hours of continuous operation with Lithium ion rechargeable battery, Accessories like Wrist strap, 2-in-1 USB- C to USB-C/A cable, quick-start guide, short instructions and case, Calibration Certificate, Make- Krykard, Model- S-240 or similar of TESTO / MAGER / FLUKE. (Minimum Warrantee - 2 years). Specifications in Annexure XXXIX. | — | — | — | 3,36,300 | |
| — | 9.00 | — | — | ||
| Supply, erection, testing & commissioning of 150mm dia. (V6) vertical / horizontal type as per site requirement, energy efficient multistage submersible pump set of capacity suitable to deliver water at the rate of 1200 to 140 LPM to the head of 16 to 60 Mtr., motor power rating of 10 HP/7.5 KW approx., 415V, 3ph, 50 Hz, etc., having water filled cooling, B class insulation, IP 68 protection, complete with all accessories, as per specifications in Annexure XL. | — | — | — | 5,13,081 | |
| — | 9.00 | — | — | ||
| Supply, fixing, testing & commissioning of fully automatic programmable digital control panel for pumpsets of capacity 10 HP to 20HP, 3-phase, 440V AC with micro-processor based technology, inbuilt Single Phase Protection, Water Level Guard, Dry Run Protection, Reverse Phase Protection, Overload, Under Voltage / Over Voltage Protection, inbuilt star delta starter, Digital Ammeter, LED screen etc in mountable sheet steel encloser IP 54 protection, with lock & key arrangement, complete with all accessories, as per Annexure XLI. | — | — | — | 2,23,821 | |
| — | 600.00 | — | — | ||
| Supply, installation, testing and commissioning of submersible flat copper cable, PVC insulated & sheathed, 3 core x 4.0 sq.mm. size, as per specifications in Annexure XLII. | — | — | — | 1,38,000 | |
| — | 9.00 | — | — | ||
| Supply, installation, testing & commissioning of non clog sewage submersible pump set of 10 HP capacity, with grinding arrangement, Motor body -stainless steel, Impeller - stainless steel, Top cover, housing etc., graded casting oil path double mechanical seal, 20 meter cable 1.1KV grade insulated and sheathed with electron beam irradiated XLPE HD HOFR (Heavy Duty, Heat, Oil, Fire Retardant) water & oil proof, copper conductor flexible cable, complete with all accessories motor and base plate, as per Annexure XLIII. | — | — | — | 6,36,507 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of web based control system for operation and monitoring of electrical systems, as per specifications in Annexure XLIV. | — | — | — | 1,61,436 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of input/ output device for generation of electrical data, as per specifications in Annexure XLV. | — | — | — | 43,230 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-April-2022.pdf
ATTACHMENT
GCCCorrectionSlipNo1ofACS-14-07-2022.pdf
ATTACHMENT
GCCApril2022CorrectionslipNo_2RBDtd13122022.pdf
ATTACHMENT
IRSGCC-2022-AdvanceCorrectionSlipNo.3.pdf
ATTACHMENT
GCCApril2022ACS4.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo_5.pdf
ATTACHMENT
AnnexureVclarificationforonlinesubmissiondated14.05.2024.pdf
ATTACHMENT
AnnexureVIBAnnualContractualTurnoverGCC2022.pdf
ATTACHMENT
BankGuaranteeNewFormat.pdf
ATTACHMENT
NoRelativeFormatEmployeeofWesternRailway-Annexure-II.pdf
ATTACHMENT
NORETIREDRAILWAYEMPLOYEEGCC2022-Annexure-III.pdf
ATTACHMENT
EL-81-932-WA-632025-2026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .