| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.2 L+₹86,928.95 (2.60%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹34.6 L+₹1.2 L (3.67%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹36.3 L+₹3.0 L (8.90%)Rejected-Finance 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹36.7 L+₹3.3 L (9.90%)Rejected-Finance MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Rejected |
Tender Value
₹46.2 L
EMD Value
₹92,400
Closing Date
7 Dec 2023, 6:00 pmClosed
GE Faridkot
GE Faridkot Military Station
Special repair of OR OTM Accn Bldg No P-13 of Med Regt under AGE B/R (P-2) at Faridkot Mil Stn
2023_MES_627458_1
GE FRD-72/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE Faridkot
Class D Category a i
9 documents required · 9 mandatory
₹500
GE Faridkot
₹92,400
Yes
20 Jan 2024
8 Nov 2023
9 Dec 2023
8 Nov 2023
7 Dec 2023
23 Nov 2023
Amount
Taking down chowkats or frames n.exc 1.5 sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but n. exc 4 sqm each with shutters (without taking of shutters from the frames) complete all as specified and directed.
S&F Pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
S&F Pressed steel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
S&F Mild Steel framed work such as grills, gratings etc. with ends of bars shoulderd and/or riveted, or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks,cooler stand,ladder and similar work conforming to Fe290, Gde-E-165 complete all as specified and directed.
S&F Steel windows box type with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed .
S&F Steel ventilators with top hung shutters including hinges and steel peg stay complete all as specified and directed .
S&F 35 mm thick 2nd class hard wood, plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edges) or of vaneered partical board medium desnsity, wood partical board with commercial face veneers fitted to chowkats complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); fitted to chowkats complete all as specified and directed.
M&L for 4 mm thick, plain sheet glass, ordinary quality and glazing with oil putty or with wooden beads (supplied alongwith shutters) in squares n.exc 0.5 sqm each pane complete all as specified and directed .
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed .
S&F 4mm thick, figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed .
S&F Solid wood moulded grain printed PVC door frame of size 50mm x 47 mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. square tube, egdes will be painted to match printed sheets complete all as specified and directed .
S&F Factory Made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing all as specified and directed
S&F 100mm long mild steel butt hinges, medium weight, cold rolled fixed with screws complete all as specified and directed.
S&F Aluminium anodised, cast type, handle 150 mm size complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts, 200 mm long of extruded section complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt of length 250mm with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminium alloy and fixed complete all as specified and directed .
S&F aluminium alloy, anodised, sliding door bolt of length 300mm with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extuded sections or cast aluminium alloy and fixed complete all as specified and directed .
S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed .
S&F 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed .
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc primer complete all as specified and directed.
M&L for Preparation of old painted steel surfaces of any description,not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new or previously untreated wood or wooden based surfaces of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F in repair MS powder coated decorative drapery rod (colour as approved) 20mm dia of approved pattern & design including decorative knobs (wall side and free side) & powder coated mild steel flat iron brackets fixed with steel screws & PVC rawl plugs/grips complete all as specified and directed.
M&L for PCC 1:3:6, type C0 (using 12.5mm graded crushed stone aggregates) as in back filling of pressed steel frames, bed blocks for fixing of hold fasts etc including necessary formwork complete all as specified and directed .
Demolition of concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed .
M&L for 40mm thick, PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregates), as in floor ,finishing surfaces even and smooth without using extra cement complete all as specified and directed.
Dismantling floor tiles, stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar complete all as specified and directed
S&F Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying finishes complete all as specified and directed .
S&F Glazed ceramic coloured tiles 450mmx300mmx7mm thick (colour and shade as approved) as in vertical surfaces such as skirting/dados etc, set and jointed in neat cement slurry & pointed in white cement with pigment to match the colour of tiles over & including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed .
S&F Machine cut kota stone slab in flooring ,20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,cutting and mirror polishing over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
S&F Machine cut kota stone slab 20-25mm thick as in skirting,steps,dado,& pillars, set and jointed in cement slurry over & including 15 mm thick rendering in cement mortar1:4 and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing complete all as specified and directed
All as per Ser item No 32 here-in-before but except kota stone
M&L for mirror polishing on marble /granite/kota stone/ stone work wherever required to give high gloss finish and applying white/coloured cement with pigment to match the shade of kota stone in the joints complete all as specified and directed.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed
M&L for 75 mm thick cement concrete 1:3:6 type C2( using 40mm graded crushed stone aggregates) as in plinth protection/path finishing surfaces even and fair complete all as specified and directed .
M&L for taking down cement plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in two layers ( Ist layer 10mm thick & 2nd layer 5mm thick ) in cement mortar 1:4 with WPC on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed . Note : WPC will be measured and paid separately
M&L for rendering 15 mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for rendering 10 mm thick in cement mortar 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 Cement : 4 Coarse Sand) the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square meter, top layer 15mm cement Plaster 1:1/2:2 (1 Cement : 1/2 Coarse sand : 2 Stone chipping 10mm nominal size) in panels with grooves all round as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. Note : Payment for providing grooves shall be made separately)
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
M&L for preparation of old decorated surfaces of wall and applying two coat of distemper oil emulsion (white/tinted) after finishing the surfaces with a coat of wall care putty by hand roller complete all as specified and directed .
M&L for complete removal of existing treatment of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of distemper oil emultion (white/tinted) complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion (white/tinted) after finishing the surfaces with a coat of wall care putty by hand roller complete all as specified and directed .
M&L for preparation of newly plastered or unplastered ceiling surfaces and applying two coats of white wash after finishing the surfaces with a coat of wall care putty by hand roller complete all as specified and directed .
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed .
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with fly ash bricks using old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed .
M&L for brick work with fly ash bricks using old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed .
Taking up or down 15mm dia GI tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed .
Taking up or down 20mm dia GI tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed .
M&L for Steel water tubing of 15 mm bore, medium grade, galvanised with all fittings, laid in trenches/ fixed to wall etc complete all as specified and directed .
M&L for Steel water tubing of 20 mm bore, medium grade, galvanised with all fittings, laid in trenches/ fixed to wall etc complete all as specified and directed .
S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
S&F in repair 15mm dia angle valve/stop cock with flange, cast copper alloy, fancy type,chromium plated, concealed type with long shank & cup , screwed both ends for iron pipe complete all as specified & directed .
S&F in repair Stop valve/angle ball with flange, cast copper alloy,fancy type,chromium plated, screwed down for high pressure with crutch or butter fly handle, screwed both ends for iron pipe of 15mm bore complete all as specified and directed.
S&F in repair bib tap,fancy type,cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15mm bore pipe & fixed complete all as specified and directed .
S&F in repair pillar taps,fancy type,chromium plated ,cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of 15mm bore complete all as specified and directed.
S&F in repair Vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, CI 'P' or 'S' traps 100mm & PVC flush pipes 32mm dia including connecting to trap and to flushing pipe, anti-syphonage pipe etc including all joints and making good to floor complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (pedestel pattern/EWC/long pan) white in colour including connection pipe to union of flushing cistern, inlet and overflow pipes,connecting only to flushing cistern, anti-syphonage pipe with PVC flush pipe of 32mm dia including plastic seat with cover,white in colour with mild steel chromoum plated hinging and 'P' or 'S' trap device complete all as specified and directed.
S&F in repair 10 litres PVC,valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F in repair PVC Jet spray with 1.50 m long flexible tube including fixing arrangement complete all as specified and directed.
S&F in repair vitreous china Wash hand basin, white, flat back of size 550x400mm including cutting for and pinning in ends of brackets or erecting stand including Brass chromium plated waste coupling 32mm bore, Waste pipe PVC 32mm bore complete all as specified and directed.
S&F in repair PVC connection, 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair sheet glass shelf assembly, consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repair brass chromium plated overhead shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union of size 15mm bore complete all as specified and directed.
S&F Towel rail, 450mm long of PTMT, fixed with and including chromium plated brass screws and wooden and plastic cleats ( minimum weight 170gms ) complete all as specified & directed.
S&F Vitreous china half stall Urinal of size 635x395x420mm, white including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe and chromium plated self closing 15mm bore push cock including Brass chromium plated waste coupling 32mm bore, Waste pipe PVC 32mm bore complete all as specified and directed.
S&F PVC waste pipe, 32 to 40 mm for WHB/Sink /urinal up to floor trap and fixed complete all as specified and directed.
Dismantling CI/PVC/RCC pipe of any dia alongwith fittings ,below or above GL/laid in floors/fixed to walls jointed in cement mortar complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F PVC (SWR) bends any radius ,110mm bore complete all as specified and directed.
S&F 100mm dia cast iron soil, waste and vent pipe, in any length with or without ears with cement joints, laid in trenches/in floors or fixed to walls complete all as specified and directed .
S&F 75mm dia cast iron soil, waste and vent pipe, in any length with or without ears with cement joints, laid in trenches/in floors or fixed to walls complete all as specified and directed .
S&F in repair CI bends, diminishing pieces or tapers, bore of pipe 100 mm complete all as specified and directed .
S&F in repair CI bends, diminishing pieces or tapers, bore of pipe 75 mm complete all as specified and directed .
S&F in repairs Cast iron floor trap, long neck, 75 mm dia with stainless steel grating including jointing to waste pipe, fixed in cement concrete type B1, 1:2:4 complete all as specified and directed .
S&F cast iron vent cowls ,bore of pipe 75mm complete all as specified and directed .
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 2000 Ltr capacity,trippled layered, hoisted and fixed in position including PTMT float valves, high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in position including all necessary fittings complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5m deep and 1.5m wide, for foundation etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed.
Returning, filling in,including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed .
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
Demolition and breaking up drain pipe (Salt glazed stoneware, AC or Reinforced concrete) 150 mm dia, set in cement mortar including demolition of haunching concrete and disposal off rubbish to a distance not exceeding 50M complete all as specified & directed .
S&F Reinforced concrete pipes of size 150mm (internal dia),class NP-2 (ISI marked) laid, jointed and tested complete with collar complete all as specified and directed .
M&L for Concrete bed to drain pipes using PCC 1:3:6 type C-2 40mm graded stone aggregate including packing under haunching against the sides of pipe after laid & tested for 150mm bore of pipes complete all as specified and direced.
Demolition of concrete in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of ) and disposal of retrieved material to a distance n.exc 100m from the starting point complete all as specified and specified.
M&L for 25mm thick (average thickness) PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in roof in specific gradients/slope complete all as specified and directed .
M&L for rendering 10 mm thick in cement mortar 1:3 with WPC on fair faces of brick work or concrete surfaces as in roof complete all as specified and directed . Note : WPC will be measured and paid separately
Supply only Liquid water proofing compound.
M&L for Roof Treatment as specified below and as directed : (a) Cleaning, washing of surface and removing all existing bitumen coatings/ APP membrane completely with intense wire brushing or high speed water jet. Surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal/ Epoxy Primer/ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm (0.20 kg BTD+0.20 Kg water) (d) Laying polyster reinforced fiber net/50 gsm Geotextile mesh, upto 300 mm on walls. (e) Applying three coat of HydroShield PUD microfibre reinforced UV resistent polyurethane (solid content 68% ) / Damp Proof ultra UV Stable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers (Solid content 55%)/ SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%)/Single Component Elastomeric Liquid Membrane ShaliUrethane BTD White/coloured (Elongation 400% ± 50, Solid Contents > 80% & Specific Gravity @ 30 OC 1.5 ± 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (f)) Complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Note (i) The treatment shall be carried out as per the manufacturer's instructions, and as directed by Engineer-in-Charge. (ii) The plan area of floor shall be considered for payment.
M&L PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in roof kerbs or mud stops, rounded or chamfered angles complete all as specified and directed.
S&F for 0.56mm thick, plain aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutters, drip and straight flashing complete all as specified and directed.
M&L for water proofing treatment to RCC sunken slab as specified below and as directed by Engineer in Charge:- (a) Cleaning the surface with wire brush/coir brush, removing loose material like dust particles, dirt etc. (b) Rendering 15 mm thick in cement mortar 1:3 using water proofing compound on raised vertical surfaces. (c) Creating fillet covering of 50 x 50 mm with polymer modified mortar on the junction of slab and wall (d) Apply first coat of two component modified polymer coating on the horizontal and vertical surface upto 300mm above wall surfaces. (e) Provision of polyester reinforced coated net of 45gm/sqm, 2.5mm x 2.5mm mm immediately on above coating. (f) Apply second coating of two component modified polymer coating after 72 hrs upto 300mm above wall surface. (g) Laying concrete 1:4:8 over the coating as per requirement. (h) Joining the sanitary pipes with the waterproofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and sanitary pipe with non shrink cementatious grout. (k) Complete treatment to be carried out by authorised applicator of waterproofing manufacturer.
Taking down carefully existing aluminium/copper point wiring for light, fan, socket or power bell complete with fittings such as Switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed. Note : Rate for making good shall be deemed to be included in above item rate.
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc in the existing concealed conduit with new provision of 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for for one light point/fan point/call bell point, 230 volts controlled by one switch complete all as specified and directed .
All as per Srl item No. 98 here-in-before but for one ligh point controlled by two,two way switches complete all as specified and directed
All as per Ser item No 98 here-in-before but for switch socket combination 5 Amp 5 Pin socket outlet 230 volts on same board with other switches complete all as specified and directed .
All as per Ser item No 98 here-in-before but for switch socket combination 5 Amp 5 Pin socket outlet 230 volts on independent board complete all as specified and directed .
All as per Srl item No. 98 here-in-before for Switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed .
S&F PVC Lamp holder with back plate suitable for batten fittings complete all as specified and directed .
S&F LED bulb 1 x 10 watt Lamp having luminous efficiency warranty 2 years complete all as specified and directed .
S&F complete set of tube light fitting, 1x20 watt LED (4 feet long), 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F complete set of tube light fitting, 1x10 watt LED (2 feet long), 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F ceiling rose, three terminals, PVC polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed .
S&F in repair Sub main wiring with two runs of single core PVC FRLS sheathed, insulated, copper cable of 06 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 06 Sqmm for continous earth wire drawn into existing PVC concealed conduit of suitable size complete all as specified and directed . Note :- Two runs of 06 Sqmm copper cable and one run of 06 sqmm copper wire earth continuty conductor in conduit with accessories shall be measured as one length)
S&F Piano type switch, single pole, 2 way, 5/6 amps, 230 volt, AC supply complete all as specified and directed
S&F switch piano, flush type, single pole, one way, 5 /6 Amp,230 V,AC supply complete all as specified and directed .
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230 volts AC supply complete all as specified and directed.
S&F socket outlet, two in one, 5 Pin 5 Amps, 230 Volt, AC supply, complete all as specified and directed
S&F socket outlet ,2 in 1, 5/6 pin, 15/16 Amps, 230 volts ,AC supply complete all as specified & directed.
S&F stepped type electronic fan regulator, flush type on the existing pheonolic laminated sheet etc, single phase, AC supply, 230 V and connecting up complete all as specified and directed. .
S&F in repair factory made epoxy polyester powder coated distribution board TP&N ,4 ways (VTPN DB), double door,(concealed flush to wall) (IP-42 protection) fabricated from minimum 1.2 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 250 Amps bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with space for provision for 4 pole MCCB as incommer and outgoing MCBs as required at site and conforming to IS: 8623 along with cable end box including making good disturbed surface complete all as specified and directed. NOTE: (a) MCCBs and MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of BoQ..
S&F in repair Sheet metal enclosure for DBs,SPN, double door, 230 Volts,8 ways with 200 amps rated bus bar complete all as specified and directed .
S&F MCCB 4 Pole,adjustable type ,415 V, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F MCB SP 5 to 32 Amp, 230 volts, B Curve with breaking capacity 10 KA complete all as specified and directed .
S&F MCB, SPN, 32 amps, 230V, C Series with breaking capacity 10 KA complete all as specified and directed .
S&F MCB SP 40 Amp, 230 volts, B Curve with breaking capacity 10 KA complete all as specified and directed .
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, including taking out existing one complete all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and cable cover for protection of cable shall be measured and paid separately.
S&F in repair energy efficient LED Security light fitting of 25W, pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/ roadway luminaire, with driver including electric connection, complete fitting with all accessories on and including bracket of 40mm dia,light grade ,GI pipe ,1.20 m and connecting with twin core twisted flexible copper conductor cable 1.5 Sqmm and with following specifications complete all as specified and directed :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max15%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12Hrs
S&F in repair 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
S&F in repair GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
S&F in repair Galvanised steeI tubing,25mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
S&F in repair 1X10 watt LED retrofit type bulk head fitting luminaries, die cast, aluminium alloy body, heat resistant, prismatic glass cover with specially designed gasket, lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper coductor cable with suitable size of 230 volt,50 HZ complete all as specified and directed.
Taking down and Refixing only ceiling fans and exhaust fan , any sweep, connecting up with and including three core copper flexible wire not less than 0.5 mtr for connecting from ceiling rose / connector to ceiling fan/exhaust fan complete all as specified and directed
Supply & fixing Energy efficient Ceiling fan complete with blades, down rods, electronic type regulator & accessories, 230 V,1200mm sweep, minimum air delivery 245 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor (BLDC) including writing of MES number (Black, Roman, Italic or Indian) n. exc 30cm height complete all as specified and directed.
Supplying and fixing and commissioning of electric water heater (Gyser) storage type ABS body of capacity 25 ltrs, BEE appreoved 5 star rating, 230V,single Phase, AC supply inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined quoting complete with all accessories such as safety valve thermostate NRV, connection piece PVC connection for hot and cold water 3 core PVC insulated PVC sheated copper conductor flexible cable including 15 Amp plug suitable for existing socket and fixing material, 04 Nos nut bolt grouting in wall in PCC(1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed .
S&F in repair Rigid non metallic PVC conduit 25mm bore exclusive of boxes(junction/terminal) but inclusive of all tees,bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe kooks etc complete all as specified and directed . Note :- A Sum of Rs. 64,993.55 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 28 & 29 (Schedule of credit) of Tender Documents.
M/S RAJESH KUMAR and CO.
mehar buildcon
M/s PANKAJ KUMAR
N.G BUILDERS
VISHAV CONSTRUCTIONS
GS and Co
SHIV SHAKTI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .