Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | ₹12.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹12.6 L+₹4,736 (0.38%)Rejected-AOC | ₹12.6 L+₹4,736 (0.38%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹16.4 L+₹3.8 L (30.4%)Rejected-AOC 2ND FLOOR 2B SORAJ ESTATE ULUBARI K C PATOWARI ROAD ULUABRI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | ₹16.4 L+₹3.8 L (30.4%) | L3 | Rejected-AOC Not Lowest |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
9 Mar 2021, 6:00 pmClosed
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO. GE (I) (AF)/SHL/ OF 2020/21 PROVN OF AIR CONDITIONERS FOR CERTAIN TECHNICAL BUILDINGS AT AF STATION LAITKOR PEAK UNDER GE (I) (AF) SHILLONG
2020_MES_408089_3
8033/20/SHL/2020/21
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
SHILLONG LAITKOR PEAK
For Enlisted Contractors Class E Category b i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I) (AF) SHILLONG
₹23,000
Yes
8 May 2021
22 Feb 2021
11 Mar 2021
22 Feb 2021
9 Mar 2021
25 Feb 2021
22 Feb 2021 - 23 Feb 2021
Amount
Supply, installation, testing and commissioning dual rotor compressor inverter technology split type air conditioners capacity 2.0 TR, 5-Star rating, single phase, 230V, 50Hz, designed for ambient temp (Cooling) 52 degree celcius with acoustic jacket on compressor, suction tube size outer diameter 5/8", liquid tube size outer diameter 3/8", power supply to outdoor unit source 4 core 2.5Sqmm, power supply to indoor unit source 3 core 2.5Sqmm complete with cordless remote control unit LCD with back lit with night glow function on remote buttons and remote battery type AAA including supply and fixing/grouting of a set of best quality mounting bracket for out door unit complete all as specified and directed. Model/Make : Model No. IC524DATU of BLUE STAR or equivalent model of O-General/Hitachi/Voltas/Daikin/Carries /LG/Samsung. Notes : (a) Cost of cutting holes into any type of wall/construction for passing of suction/liquid tube, drain pipe and connetion wires including making good distrubed surface of wall/construction to match existing shall be deemed to be included in quoted rates. (b) The contractor shall deposit with Engineer-in-Charge original purchase voucher and product guarantee/warrantee certificate in original for the period as per policy in vogue of manufacturer to obtain service from manufacturer during the period of guarantee/warrantee.
Supply and fix pair of copper tube 5/8" and 3/8" of standard quality as required at site duly insulated by best standard quality insulating material for additional length of sunction/liquid pipe between indoor unit & outdoor unit beyond the length of copper tubings provided by company/manufacturer including testing for leakage of refrigerent complete all as specified and directed.
Supply and fixing low density polythelene pipes (LDPE) 25mm dia including jointer for additional length of drain pipe beyond the length provided by manufacturer of AC including sealing and making leak proof complete, all as specified & directed.
Supply and fix/lay PVC insulated & PVC Round Sheathed 3 core 2.5 Sqmm multistranded copper conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 as additional length to be used for connection between indoor and outdoor unit beyond length provided by manufacturer of AC complete all as specified and directed.
S&F wall mounted type in-line-Voltage Stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type and designed for output voltage stabilized at 230 V with accuracy of + 2.5% complete all as directed. Model/Make : Model No. VS514DTA-GT of make BLUE STAR or equivalent model of Make : V-Guard/AE/Microtek/Luminous/Godrej.
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP 20 Amps, complete all as specified and directed.
S & F sheet metal enclosure vertical type double door DB TPN 8 way suitable to accomodate MCCB FP, 415 volts protection class IP-42 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 250 Amps capacity all as specified and as approved by Engineer-in-Charge. {Model/Make : Cat Part No DHDLVDRWGOF008 of make Havells or equivalent model of makes listed in List makes}. (Note: MCCB & MCBs shall be measured and paid separately)
MCCB four pole 63 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 16 KA at 415 V AC , 50 Hz
S & F MCB SP 6 to 32 Amps, 240 volts, C-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS-H cable 1100 Volt grade with 10 Sqmm copper multistranded conductor drawn through and including PVC casing caping on walls/ceilings/roofs including 10 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS-H cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Note : - Two runs of main cable, one run of earth continuity conductor and one run of casing caping will be measured and paid as one length only.
Supplying, Fixing/laying, jointing and testing and commissioning, LT under ground cables, 1100 Volts grade, XLPE insulated, armoured heavy duty electric cable with stranded aluminuim conductors, laid in trenches, ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe complete all as specified and directed of following sizes:-
3.5 core 70 Sqmm
M & L for heat shrinkable cable end termination jointing kit for 1100 Volts grade LT XLPE/PVC cable of following size complete with jointing material and accessories complete all as directed :-
70 to 150 Sqmm, 3.5 core
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 15mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
Arbind Enterprise
RS COOLING APPLIANCES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .