Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.6 LAccepted-AOC KHAMDONG SINGTAM EAST SIKKIM SIKKIM EAST SIKKIM SIKKIM 737134 | EAST DISTRICT | SIKKIM | 737134 | ₹82.6 L | L1 | Accepted-AOC L1 |
Tender Value
₹75.2 L
EMD Value
₹1.5 L
Closing Date
16 Sept 2022, 5:30 pmClosed
Dy. General Manager (Elect)
Procurement and Contract Division, Teesta-V Power Station, Balutar, Singtam, Distt- East Sikkim-737134
Construction of HT and LT panel room with Emergency rest room over HT and LT panel room at Dam intake area of Teesta-V Power Station
2022_NHPC_694458_1
NH/TSV/Cont/CC-286/NIT-757
Open Tender
Civil Works
Works
180 days
Teesta-V Power Station, Balutar, Singtam
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,180
Yes
NHPC LIMITED
₹1.5 L
Yes
6 Jun 2023
13 Jun 2022
21 Sept 2022
13 Jun 2022
16 Sept 2022
13 Jun 2022
13 Jun 2022 - 15 Sept 2022
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Filling inside plinth in building works with 20cm layers, consolidated to 15 cm including watering ,rammingetc, all complete.
Providing and Laying in position cement concrete of specified grade including compacting curing etc all complete. 1:3:6 mix. (1 cement, 3 coarse sand, 6 stone aggregate of 40mm & down size)
Providing, fixing & removing form work for casting R.C.C items as indicated below: with with locally available timber) Beam, lintels, girders, brersumers and cantilevers.
Providing, fixing & removing form work for casting R.C.C items as indicated below: with with locally available timber) Foundation, footings, base of column etc for mass concrete.
Providing, fixing & removing form work for casting R.C.C items as indicated below: with with locally available timber) Wall
Providing, fixing & removing form work for casting R.C.C items as indicated below: with with locally available timber). Floor slab, roof slab, landing, balcony and access platform.
Providing, fixing & removing form work for casting R.C.C items as indicated below: with with locally available timber). Square columns
Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and Laying in position specified grade of reinforced cement concrete excluding the cost of form work, finishing and reinforcements. 1:2:4 (1cement, 2coarse sand, 4graded stone aggregate of 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
Supplying, bending and placing in position tor steel reinforcement in all R.C.C works including cost of binding wires, all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Providing and laying first class brick work in half brick thick in superstructure o fstandard size bricks with 1:4 cement mortar (1cemen tand 4 course sand including carriage of bricks up towork site, curing etc all complete.
Providing and Laying first class brick work in one brick thick in superstructure o fstandard size bricks with 1:5 cementmortar (1cement and 5 clean coarse sand) as per the direction of Engineer in Charge including curing etc all complete.
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and Laying 12mm thick cement plaster of specified mix in single coat including finishing even and smooth and curing complete. 1:3 Mix
Providing and Laying white or colored glazed vitrified tiles Pearl (white, marvel Atlanta,jet blacket corequivalent)in flooring, treads of steps landing etc laidonabed of 15mm ,cm1:3 (1cement,3coarsesand) finished with flush pointing with white cement slurry.
Providing and Laying white or colored glazed tiles of size 200mmx300mm of plain/normal prints colours (white, grey, ivory, platinum ,cream, glacierwhite ,summersand, beach, woodduro, melody, orequivalent) in skirting, risers of steps and Dadoson 12mm thick cement plaster(1cement, coarsedsand) 1:3 bare and jointed with white cement slurry.
Providing, fitting and fixing white vitreous china pedestal (European type) water closet (W.C) pan with seat and lid, with C.P. brasshinges, 10ltr low leve lcistern with fittings and brackets 40mm flush bend, 20mm over flow pipe with specials, including Providing and painting and making good the wall and floors a srequired all complete: W.C. pan European Bidets standard CAT NO 30001
Providing and fitting chromium plated toilet paper holder including the making holes and fixed to timber cleats with CP screws washer etc. all complete:.
Providing, fitting and fixing soil, waste and vent pipes including testing etc complete. 100 mm dia. PRINCE / SUPREME or equivalent soil pipe
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Sand cast iron S&S as per IS - 1729 .
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x100x100 mm. Sand cast iron S&S as per IS - 1729
Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diameter : 100 mm
Providing and fixing collar. Sand cast iron S&S as per IS - 3989
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 25 mm dia nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. arrangement of approved quality and colour.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length. 15 mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15mm nominal bore
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing brass stop cock of approved quality : 15 mm nominal bore
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of :Light shade pigment using white cement
Brass full way valve with C.I. wheel (screwed end) 25 mm dia
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet. Sand cast iron S&S as per IS: 3989. Sand cast iron S&S as per IS: 3989
Providing and placing on terrace high density polyethylene water storage tank with man hole lid and suitable locking arrangement including making holes for inlet, out let and ball cock including testing etc. all complete: (Sintex or equivalent). 1000 LITERS CAPACITY
Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to all/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
P/F/F in position of fully glazed shutters in windows and doors of champ wood or equivalent including steel but thinges ,screws ,3mm glass panes of modiguard or equivalent etc complete.
Providing fitting and fixing water proof flush doors shutters, solid block hard core construction with frame of 1st class hard timber, with well matched 3mm commercial ply (both faces) including hinges with screws complete. 30mm.
Providing, fitting and fixing. Tower bolts 250x10mm with necessary screw etc complete. Brass (Bright Finish)
Providing, fitting and fixing. sliding door bolts with nuts and screws etc. complete. Size 300x16mm. Brass (bright Finish)
Providing, fitting and fixing. Handles 125 mm size with necessary screws etc complete. Brass (Bright Finish)
G.I Barbed wire Fencing 1.8 metre high (Providing and fixing 1.8 metres high GI barbed wire fencing with 2.4 m angle iron posts 50mmx50mmx6mm placed every 3 metres center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner posts hall best rutted on both sides and end post on one side only and provided with 12 horizontal lines and 2diagonals inter woven with horizontal wires,fixed with GI staples, turn buckle setc complete as per clause 807 )
Tubular Steel Railing on Medium Weight steel channel (ISMC series) 100mmx50mm (Providing, fixing and erecting50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100mmx50mm, 1.2 metres high above ground, 2m centre to centre, complete as per approved drawings)
Providing fitting and fixing rolling shutters of approved make, made of required size MS laths inter locked together through their entire length and joined together at the end by end lock mounted on specially designed pipes haft with brackets, sideguides and arrangements for inside and outside locking with push and pull operation complete including providing and fixing wire springs grade No2 and MS top cover o frequired thickness of rollings hutters as per the direction of ngineer-in-Chargeall complete.
Distempering with dry distemper on New surface two or more coats of required shade to give an even and uniform shade including priming coat of whiting to give an even shade after thorough cleaning of dirt, dust, loose pieces o fscabs, grease etc including surface preparation by sand papering etc complete. New surface
Providing and painting with plastic Emulsion paints two or more coats on New surface of required shade to give an even shade including brushing the surface clean of all dirt dust ands moothened by sand paper etc complete.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sq.mm
Safe earthing model T-19 short current 20KA RMS for 1 sec (LV/MV) application:- 50 mm diameter X 2 mtrs electrode (copper bonded ) & one bag backfilled chemical compound.
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 63A TPN
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral .
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, Upto 450 mm sweep.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying of 20 Watt LED tube light with complete fittings
Supplying of modular indicator (for switch board)
Supplying of ceiling fan
Supplying of Exhaust fan
Supplying of LED bulb 9W
Supplying of surface light 12watt
Supplying of 3.5 core x 25 sqmm armoured lt xlpe insulated cable.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .