| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | ₹36.6 L Quoted ₹37.2 L | L1 | Accepted-AOC 1ST LOWEST |
| 2 | L2₹39.3 L+₹2.1 L (5.76%)Rejected-Finance | ₹39.3 L+₹2.1 L (5.76%) | L2 | Rejected-Finance 2ND LOWEST |
| 3 | L3₹45.1 L+₹7.9 L (21.2%)Rejected-Finance | ₹45.1 L+₹7.9 L (21.2%) | L3 | Rejected-Finance 3RD LOWEST |
| 4 | L4₹48.3 L+₹11.1 L (29.8%)Rejected-Finance | ₹48.3 L+₹11.1 L (29.8%) | L4 | Rejected-Finance 4TH LOWEST |
| 5 | L5₹49.6 L+₹12.4 L (33.4%)Rejected-Finance | ₹49.6 L+₹12.4 L (33.4%) | L5 | Rejected-Finance 5TH LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
21 Jul 2022, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR TO TOILET SUNKEN FLOOR WATER PROOFING TREATMENT TILLING OF CERTAIN BLDG AT ARMY AD CENTRE INCLUDING REPAIR MAINTENANCE OF CENTRIFUGAL PUMP SETS MONOBLOCK PUMP SETS SUBMERSIBLE PUMP SETS FILTRATION PLANTS AND DESALINATION PLANT AT GMS UNDER GE
2022_MES_533998_1
8000/07/2022-23/0906/E8
Open Tender
Civil Works - Highways
Item Rate
270 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹70,000
Yes
7 Sept 2022
27 Jun 2022
23 Jul 2022
27 Jun 2022
21 Jul 2022
12 Jul 2022
Amount
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) dark/colour shade polished,area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 20mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item No 4 above but on vertical surface of wall of size 600x600x10mm thick as in dado/skitting including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surface 200x300x7 mm thick coloured on vertical surfaces such as dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 10mm thick rendering in CM 1 :4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
All as per item No 8 above but vertical surfaces area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm as skirting non skid ceramic tiles.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
All as per item No 10 above but vertical surfaces area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm as skirting non skid ceramic tiles.
M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for cement concrete tiles of size 250 mm x 250 mm x 20-22 mm thick machine pressed set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, including 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L moorum / red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for sand cushioning including spreading in layers and rolled consolidated to thickness of 50mm (minimum) for receiving precast PCC interlocking blocks complete all as specified and directed
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on other than fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement and mixed with water proofing compound complete all as specified and directed. (Note: supply only of WPC shall be measured and paid for seperately ).
Supply only integral water proofing compound all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and smooth without using extra cement to receive the topping layer complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 300 x 200 mm x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles including 10mm thick rendering in CM 1 :4 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20mm thick screed bed in CM 1 :6 complete all as specified and directed.
All as per itme No 27 above but vertical surfaces area of each tile exceeding 0.06 sq m but not exceeding 0.11 sqm as skirting non skid ceramic tiles complete all as specified and directed
Taking up or down GI steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down GI steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
Taking up or down GI steel tubing and connections including cleaning if refixing required for 25 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade (ISI marked) with all fittings fixed to walls and ceilings or laid in floors of 25 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 Type B-2 using 40mm graded stone aggregate in pavement/hard-standing laid in alternative panels, surface finished even and smooth without using extra cement, including necessary form work, complete all as specified and directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 100 mm internal dia of pipe complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F stack clamps made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nut and securing ends of stays to wall or roof for 50 mm bore of pipe complete all as specified and directed.
Taking down existing water proofing membrance and cleaning roof, plastered surface etc preparing the surface to receive plaster by brushing with wire brush and fanning the surface to remove all loose dirt etc and brushing neat cement slurry @ 3.00 Kg/Sqm complete all as specified and directed.
M&L for rendering 15 mm thick surface as in roof with integral water proofing compound 3% by the weight of cement in cement mortar 1:4 complete all as specified & directed. (Integral WPC will be measured and paid separately).
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in sub base flooring 40 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L for water proofing treatment to roof surface complete all as specified & directed with the followings :- (a) Apply bituminous based primer confirming to IS: 3384-1965 @ 0.30 kg/sqm. (b) APP modified bituminous membrane 3mm thick with non woven polyester core of weight not less than 3.2 to 3.5 Kg/sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions. (c) Applying bituminous based aluminium paint @ 0.20 Kgs/Sqm in two coats over APP membrane
Demolition of cement concrete (un-reinforced) other than ground floor compelte all as specified and directed.
M&L for 30mm thick PCC 1:2:4 type B-0 using (12.5mm graded stone aggregate ) as in sunken floor mixed water proofing compound finished surface even and smooth with using extra cement complete all as specified and directed. Note : water proofing compound shall be measured seperatly.
M&L 15mm thick rendering cement plaster in cement mortar 1:3 as in brick/concrete surface of sunken portion using water proofing compound complete all as specified and directed. Note : water proofing compound shall be measured & paid seperately
M&L wire brushing and cleaning top surface of cement concrete including flashings and junction of parapet etc. and surface painting with a layers of blown grade bitumen of any penetration applied hot @ 1.7 kg per sq.m. blinded with grit or pea size gravel @ 0.006 cu.m. per sqm and lightly tampered (area of flashings, etc., shall be added to the roof area) complete all as specified and directed.
M&L Cement concrete 1:5:10 type E2 using 40 mm using graded stone aggregate as in sunken floor, foundations, filling and mass-concrete finished surface fair and even complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M & L for one coat of cement based paint on old plastered surface of walls including preparation of surfaces complete all as specified and directed.
M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing old plastered surfaces of wall and applying one coat of weather proof exterior emultion (APEX of Asian paint or equivalent) Complete all as specified and directed.
M&L for preparation of old treated surfaces of wall by complete removing of existing treatment and applying two coat of oil bound distemper over a coat of 1 mm thick wall putty and primer complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall with complete removal of existing treatment and applying two coat of cement based paint complete all as specified and directed.
M&L for two coats of cement based paint on new plastered surface of walls including preparation of surface complete all as specified and directed.
M&L Plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as concreting filling and mass concrete complete all as specified and directed.
S&F in repair Star Detla Timer 0-30 Seconds duration complete all as specified and directed. make: L&T/Havell's/C&S
S&F in replacement CT Coil 60/5 Amps complete all as specified and directed.
S&F in replacement CT Coil 30/5 Amps complete all as specified and directed.
S&F in replacement of MCB TP 40 amps complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S.
S&F in replacement gun metal NRV of size 50 mm dia complete all as specified and directed. Make : ZOLOTO/Leader/Upadhyay
Carrying out Chemical analysis test of water collected from bore wells through Govt approved lab complete all as specified and directed.
M & L for Overhauling/Backwash & cleaning of the desalination Plant at GMS with Citric Acid-10 kgs and 5 Micron Catrige Filter-04 Nos complete all as specified and directed. NOTE: Every Overhauling/Backwash will be measured separately as each Job
S&F in replacement of low/high voltage monitoring device 440 volts, 3 phase complete all as specified and directed. Make- EAPL/L&T./Minilec
S&F in replacement of phase monitoring device 440 volts, 3 phase complete all as specified and directed. Make- EAPL / L&T/Minilec.
S&F in replacement of Dry run & over load protection with phase failure relay alongwith suitable CTS complete all as specified and directed. Make : EAPL/MINILEC
S&F in replacement of electronic adjustable cyclic timer complete all as specified and directed. Make : EAPL /L&T/Minilec.
S&F in replacement Voltmeter digital type (0-500V) complete all as specified and directed. Make : AE/L&T/HPL
S&F in replacement Ammeter digital type (0- 100 Amps) complete all as specified and directed. Make : AE/L&T/HPL
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 415 v, TP suitable for 200/250 mm bore well (Casing pipe size200/250mm)supply and install 3 HP, 40 mtr Head,105LPM, 38mm outlet (Model KS4C- Series Make :Kirloskar/CRI including lowering by manpower & mechanical complete all as specified and directed. NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 415 v, TP suitable for 200/250 mm bore well (Casing pipe size200/250mm)supply and install 5 HP, 75 mtr Head,180LPM, 50mm outlet (Model KS6B- Series Make :Kirloskar/CRI including lowering by manpower & mechanical complete all as specified and directed. NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing 02 Nos and motor terminals plate/cable ducts complete of capacity 30 HP including painting complete all as specified and directed.
All as per item No 86 above, but of capacity 20 to 25 HP electric motor any type.
All as per item No 86 above but of capacity 10 to 15HP electric motor any type.
All as per item No 86 above but 5 to 7.5 HP electric motor any type.
All as per item No 86 above but 1 to 3 HP electric motor any type. Note for item No 86-91 :- Pump/Motor shall be dismantled and winding shall be tested continuity at site if winding fail/burnt is established than winding shall be cut at site before issuing gate pass. The quoted rate deemed to included .
Dismantling of submersible motor 7.5 HP 3 phase from pump house at any location in GMS area under AGE E/M GOS Yard, transporting to contractors workshop, dismantling and carrying out necessary repairs/replacement of motor as per the following :- (a) Cutting out existing winding of starter of submersible motor of any make and rewinding with same size of copper winding wire as existing as directed by the EIC. (b) Straightening the slot of starter of submersible motor of any make (c) Replacement of thrust washer and bearing complete of submersible motor of any make. (d) Replacement of worn-out bushes of submersible motor as per manufacturers design and specification. (e) Replacement of sand guard (f) Providing of sleeves in end plate of submersible motor (g) Replacement of cable gormmet (h) Replacement of water seal (i) Replacement of studs with nuts (j) Lathe work of motor shaft, turning to bring it to original size and shape and plastering of shaft of submersible motor for smooth functioning on described amps
All as per item No 91 above but capacity of 5 HP
All as per item No 91 above but capacity of 3 HP Note for item No 92 to 94 :- Pump/Motor shall be dismantled and winding shall be tested continuity at site if winding fail/burnt is established than winding shall be cut at site before issuing gate pass. The quoted rate deemed to included .
Dismantling of submersible pump 7.5 HP capacity from pump house at any location in GMS area under AGE E/M GOS Yard, transporting to contractors workshop, dismantling and carrying out necessary repairs/replacement of pumps/Testing as per the following:- (a) Replacement of coupling complete all as specified and directed. (b) Overhauling of submersible pump and carrying out the following repairs. (c) Lathe work including balancing of pump shaft and cutting of key slots (d) Re-threading of worn-out studs holes and providing over size studs with nuts (e) Replacement of bowel bushes (f) Replacement of neck ring (g) Replacement of steel distance pieces (h) Replacement of bowel (j) Replacement of head extension
All as per item No 94 above but capacity of 5 HP
All as per item No 94 above but capacity of 3 HP
S&F in replacement of impeller upto 7.5 HP submersible pump set complete all as specified and directed.
Dismantling complete Centrifugal /Mono Block motor of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers. Rematlling and balancing of shaft, replacement of gunmetal bush bearing and gland packing of pump set. and refitting the same after the repair/replacement dulycomplete all as specified and directed tested for smooth functioning capacity of 30 HP
All as per item No 98 above but capacity of 20 to 25 HP
All as per item No 98 above but capacity of 10 to15 HP
All as per item No 98 above but capacity of 5 to 7.5 HP
All as per item No 98 above but capacity of 1 to 3 HP
Disconnecting the electric connection and taking out the submersible pump set from bore / open well upto 7.5 HP including GI column pipe complete and lowering down repaired motor with column pipe, welding joints and connecting electrical connection as directed and transportation of submersible pump set upto 7.5 HP 3 phase from pump house to any location in GMS area to contractors work shop repaired pump set for relowering, dismantling and carrying out necessary repairs complete all as specified and directed.
S&F in replacement of old rusted GI Column Pipe heavy grade of size 50 mm dia in pieces of 3.3 metre long , lathe m/c threaded both ends in the bore/open wells complete all as specified and directed.
S&F in replacement of old rusted heavy grade GI socket of size 50 mm dia complete all as specified and directed.
S&F in repair PVC insulated submerssible cable water proof flate type 3 core with standard copper conductor cable, 4 Sqmm, 1100 volts grade including cable lugs/joints, connection to submerssible motor and other end to aluminium armoured cable including jointing complete all as specified and directed. (Make: Finolex /Polycab/Plaza
S&F in repair HDPE Borecaps of size 200/250mm dia complete all as specified and directed.
S&F in repair of steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia(multi wire steenless steel) for holding of submersible pump motor set complete all as specified and directed.
Supply and replacement contactor 16 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ Make – CG/L&T/BCH/ HAVELL’S/Seimens.
All as per item No 109 above but 25 Amps capacity.
All as per item No 109 above but 32/35 Amps capacity.
All as per Item No 109 above but 40/50 Amps capacity
Dismantling complete Centrifugal Plunger high speed pump set capacity 30 HP of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers , Rematlling and balancing of shaft, replacement of gunmetal bush bearings and gland packing of pump set including changing of sleeves , packing , oil seal and water seal and refitting the same after the repair/replacement duly by the changing of plungers , pistons rod assembly and replacing of gear oil complete all as specified and tested for smooth functioning of capacity 20 TPD Desalination plant Note :- Supply only for Plungers and Piston rod assembly,Oil seal ,Gland packing is paid and Measured separately .
Supply only plungers suitable size and as per required at site
Supply only Piston rod assembly as suitable size and as per required at site
Supply only Oil Seal as suitable size and as per required at site
Supply only Gland packing as suitable size and as per required at site
S&F in replacement of DOL starter for submersible pump set type MK-I and relay range 9-14 amps with contactor complete all as specified and directed. Make : C&S/L&T/CG
S&F in replacement thermal over load relay of range 6.5 to 10 Amps complete all as specified and directed. Make- CG/L&T/ BCH/C&S.
All as per item No 119 above but 15 to 22 Amps capacity.
All as per item No 119 above but 24 to 34 Amps capacity.
S&F in replacement of indicating lamp set (RYB) LED type complete all as specified and directed.
S&F in replacement of MCCB 4 Pole , 415 V , 160 Amps with breaking capacity 36 KA panel mounting type , AC, Make – CG/HAVELL’S/ L&T/C&S.
S&F in replacement of MCCB 4 pole , 415 V , fixed type 25 TO 100 Amp panel mounting type ,with breaking capacity 16 KA AC complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S.
M/S. KISHAN ENGINEERING
M/s Ats Electricals
G.KRISHNA MURTHY AND PARTNERS
M/s MAA BHAIRABI ENTERPRISES
HARAGOURI SUPPLIERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .