Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.9 CrAccepted-AOC BARNALI TOWER MIRZA KAMRUP ASSAM PIN 781125 | KAMRUP | ASSAM | 781125 | ₹74.9 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹77 CrRejected-AOC | ₹77 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹66.9 Cr
EMD Value
₹1.3 Cr
Closing Date
2 Apr 2024, 2:00 pmClosed
CE, PWD(Roads), Assam, Chandmari, Ghy-3
O/O The CE, PWD(Roads), Assam, Chandmari, Ghy-3
Package No. ROB/ST-5/ASSAM/BHARALUMUKH/01 Construction of ROB at LC Gate No. ST-5 at Km-8/2-3 on R.K. Choudhury- M.G. Road under Construction of ROBs on 50_50 Cost Sharing Basis
2024_PWD_37183_1
CE/STBR/II/32/2023-24/9 Dated 08-03-2024
Open Tender
Civil Works – Roads
910 days
BHARALUMUKH
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,000
₹1.3 Cr
Yes
5 Oct 2024
13 Mar 2024
3 Apr 2024
13 Mar 2024
2 Apr 2024
13 Mar 2024
13 Mar 2024 - 2 Apr 2024
Amount
1. FOUNDATION: ROB (Span Over Railway Line) Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil. B. Mechanical Means (II) with dewatering. (i) Depth upto 3 m
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shutteringformwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shutteringformwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (Pile diameter-1200 mm)
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or quivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. D. RCC Pile Cap M35 Grade (ii) Using Batching Plant, Transit Mixer and Concrete Pump
Levelling course for Pile cap (PCC M15 Grade)
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in foundation complete as per draw ing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
Providing steel liner 08 mm thick for Pile including fabricating upto required length and setting out as per detailed drawing (rate as per Assam PWD's approved rate)
SUBSTRUCTURE: Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (For Pier including pier cap). a. Height upto 5m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (For Pier including pier cap). b. Height 5m to 10m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC/PSC Grade M45 (For Pedestal), Rate Carry over from Superstructure , a. Height upto 5m & 5m to 10.00m. case II. With Batching Plant, Transit Mixer and Concrete Pump
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per draw ing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainlesssteel matting surfaces, complete assembly to be of cast steel/fabricated structural steel, meatal and elastomer elements to be as per IRC:83 part-I &II respectively and parts conforming to BS:5400, section 9.1 & 9.2 and clause 2006 of MORTH&S Specification complete as per drawing and approved technical specification.
SUPERSTRUCTURE: Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. P. With plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45. Case ii. Using Batching Plant, Transit Mixer and Concrete Pump (ii) Slab . B. Height 5m to 10m
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel Jindal panther steel/ Shyam steel or equivalent)
Structural steel Built up girder (BUG) (Structural steel Built-Up-Girder (BUG): Providing and launching Steel Truss of Structural steel BUG Super Structure of Grade E350 including painting complete as per as per drawing and technical specifications under Section 1900 of MOST)
Mastic Asphalt Wearing Course: Providing and laying 25 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.
Bituminous Concrete Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) With rock dust as filler With VG-30 grade Bitumen for Grading II ( 13 mm nominal size )
Tack coat (Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.)
Drainage Spouts complete as per drawing and Technical specification
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification
RCC Crash Barrier(M 40 grade concrete) (RCC Crash Barrier including reinforcement complete as per drawing and Technical Specifications)
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)
Receiver Pipe for drainage spout
SUPERSTRUCTURE: (MISCALLAENEOUS WORKS) Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, eff lorescence and applying paint @ of 1 litre for 2 Sq.m. A) For Plain surface
Structural steel Built up girder (BUG) (Providing and launching Steel Truss of Structural steel BUG Super Structure including painting complete as per as per drawing and technical specifications under Section 1900 of MOST.) Stair Case
Structural steel Built up girder (BUG) (Providing and launching Steel Truss of Structural steel BUG Super Structure including painting complete as per as per drawing and technical specifications under Section 1900 of MOST.) Inspection Ladder
2. FOUNDATION: VIADUCT Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil. B. Mechanical Means (II) with dewatering. (i) Depth upto 3 m
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil. B. Mechanical Means (II) with dewatering. ii) Depth 3 m to 6 m
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shutteringformwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shutteringformwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (Pile diameter-1200 mm)
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103- 1999. D. RCC Pile Cap M35. (ii) Using Batching Plant, Transit Mixer and Concrete Pump
Levelling course for Pile cap (PCC M15 Grade)
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in foundation complete as per draw ing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
Providing steel liner 08 mm thick for Pile including fabricating upto required length and setting out as per detailed drawing (rate as per Assam PWD's approved rate)
Brick masonry work in cement mortar 1:3 in foundation complete excluding pointing and plastering, as per drawing and technical specifications (brick foundation for approach slab) B. Cement mortar1:2 (1cement :2 sand)
SUBSTRUCTURE: Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (For Pier including pier cap). a. Height upto 5m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (For Pier including pier cap). b. Height 5m to 10m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC/PSC Grade M45 (For Pedestal), Rate Carry over from Superstructure , a. Height upto 5m & 5m to 10.00m case II. With Batching Plant, Transit Mixer and Concrete Pump
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per draw ing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. (Elastomeric pad for stopper)
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainlesssteel matting surfaces, complete assembly to be of cast steel/fabricated structural steel, meatal and elastomer elements to be as per IRC:83 part-I &II respectively and parts conforming to BS:5400, section 9.1 & 9.2 and clause 2006 of MORTH&S Specification complete as per drawing and approved technical specification.
SUPERSTRUCTURE: Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. P. With plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45. Case ii. Using Batching Plant, Transit Mixer and Concrete Pump (ii) For solid slab/voided slab super-structure . B. Height 5m to 10m
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. P. With plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45. Case ii. Using Batching Plant, Transit Mixer and Concrete Pump (ii) For cast-in-situ box girder, segmental construction and balanced cantilever. B. Height 5m to 10m
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel Jindal panther steel/ Shyam steel or equivalent)
High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications.
Structural steel Built up girder (BUG) (Structural steel Built-Up-Girder (BUG): Providing and launching Steel Truss of Structural steel BUG Super Structure of Grade E350 including painting complete as per as per drawing and technical specifications under Section 1900 of MOST)
Mastic Asphalt Wearing Course: Providing and laying 25 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.
Bituminous Concrete Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) With rock dust as filler With VG-30 grade Bitumen for Grading II ( 13 mm nominal size )
Tack coat(Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.)
Drainage Spouts complete as per drawing and Technical specification
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. With TATA make TMT CRS(Fe-500) grade rebar
Filler joint: Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification.
Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight
RCC Crash Barrier(M 40 grade concrete) (RCC Crash Barrier including reinforcement complete as per drawing and Technical Specifications)
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)
Receiver Pipe for drainage spout
SUPERSTRUCTURE: (MISCALLAENEOUS WORKS) Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, eff lorescence and applying paint @ of 1 litre for 2 Sq.m. (A) For Plain surface
3. FOUNDATION: RAMP or LEG Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil. B. Mechanical Means (II) with dewatering. (i) Depth upto 3 m
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil. B. Mechanical Means (II) with dewatering. (ii) Depth 3 m to 6 m
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shutteringformwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shutteringformwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (Pile diameter-1200 mm)
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. D. RCC Pile Cap M35 Grade (ii) Using Batching Plant, Transit Mixer and Concrete Pump
Levelling course for Pile cap (PCC M15 Grade)
Supplying, fitting and placing TMT IS:1786 (Fe 500 D) bar reinforcement in foundation complete as per draw ing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
Providing steel liner 08 mm thick for Pile including fabricating upto required length and setting out as per detailed drawing (rate as per Assam PWD's approved rate)
Brick masonry work in cement mortar 1:3 in foundation complete excluding pointing and plastering, as per drawing and technical specifications (brick foundation for approach slab) B. Cement mortar1:2 (1cement :2 sand)
SUBSTRUCTURE: Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (For Pier including pier cap). a. Height upto 5m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (For Pier including pier cap). b. Height 5m to 10m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (For Pier including pier cap). c.Height above 10m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC/PSC Grade M45 (For Pedestal), Rate Carry over from Superstructure , a. Height upto 5m & 5m to 10.00m case II. With Batching Plant, Transit Mixer and Concrete Pump
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per draw ing and technical specifications a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel)
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. (Elastomeric pad for stopper)
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainlesssteel matting surfaces, complete assembly to be of cast steel/fabricated structural steel, meatal and elastomer elements to be as per IRC:83 part-I &II respectively and parts conforming to BS:5400, section 9.1 & 9.2 and clause 2006 of MORTH&S Specification complete as per drawing and approved technical specification.
SUPERSTRUCTURE: Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. P. With plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45. Case ii. Using Batching Plant, Transit Mixer and Concrete Pump (i) For solid slab/voided slab super-structure . B. Height 5m to 10m
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. P. With plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45. Case ii. Using Batching Plant, Transit Mixer and Concrete Pump (ii) For cast-in-situ box girder, segmental construction and balanced cantilever. B. Height 5m to 10m
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel /Jindal panther steel/ Shyam steel or equivalent)
High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications.
Structural steel Built up girder (BUG) (Structural steel Built-Up-Girder (BUG): Providing and launching Steel Truss of Structural steel BUG Super Structure of Grade E350 including painting complete as per as per drawing and technical specifications under Section 1900 of MOST)
Mastic Asphalt Wearing Course: Providing and laying 25 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.
Bituminous Concrete Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) With rock dust as filler With VG-30 grade Bitumen for Grading II ( 13 mm nominal size )
Tack coat(Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.)
Drainage Spouts complete as per drawing and Technical specification
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification. With TATA make TMT CRS(Fe-500) grade rebar
Filler joint: Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification.
Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight
RCC Crash Barrier(M 40 grade concrete) (RCC Crash Barrier including reinforcement complete as per drawing and Technical Specifications)
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)
Receiver Pipe for drainage spout
SUPERSTRUCTURE: (MISCALLAENEOUS WORKS) Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, eff lorescence and applying paint @ of 1 litre for 2 Sq.m. (A) For Plain surface
4. RE WALL Embankment Filling Sand Filling in Foundation Trenches as per Drawing & Technical Specification
Reinforced Earth Retaining Wall Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. (I) 180mm thick, M-35 grade RCC Facing elements of shape and size as per design and drawing with bearing pads, joint fillers, tie strips, fastener and all accessories and consumable complete.
Reinforced Earth Retaining Wall Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. (II) Assembling, joining and laying of reinforcing elements. B. With Reinforcing elements of Synthetic Geogrids
Reinforced Earth Retaining Wall Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. (IV)Construction of PCC strips level footing (35cm x 15cm) in M-15 gradeconcrete complete as per technical specification and drawing.
Reinforced Earth Retaining Wall Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. (V) Providing 600mm drainage bay behind RE wall with compacted granular material as per technical specification and drawing.
Reinforced Earth Retaining Wall Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. (VI) Construction of crash barrier, parapet, coping beam with friction slab in M-30 grade concrete complete as per technical specification and drawing.
5. Retaining WALL Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I.Ordinary soil. B. Mechanical Means. (II) with dewatering. (i) Depth upto 3 m
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining andwater reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999) (Pile diameter-1000 mm)
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. D. RCC Pile Cap M35 Grade , (ii) Using Batching Plant, Transit Mixer and Concrete Pump
Levelling course for Pile cap (M15 Grade)
Supplying, fitting and placing TMT IS:1786 (Fe 500 D) bar reinforcement in foundation complete as per draw ing and technical specifications a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications & steel shuttering formwork With plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 . a. Height upto 5m. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per draw ing and technical specifications. a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. B. Sandy material
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
6. Approach Road Granular Sub-base with Well Graded Material (Table:- 400-1) By Mix in Place Method: Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) for grading-II Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate as per Technical specificationnincluding premixing the Material with water at OMC in mechanical mix plant, carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density including lighting, barricading, and maintenance of Diversion, etc as pe Table 400.11 & 400.12 andTechnical specifications clause 406 )
Prime coat (Providing and applying primer coat as per Technical specifications with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per as per Technical specification clause 502.) i) Medium Porosity
Tack coat (Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.) Normal Bituminous surface
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 505. complete in all respect. b. With hydrated lime/ cement as filler (refer table 500-9 of MoSRT&H specification) A. With 60/70 or VG-30 grade bitumen i) for Grading I ( 40 mm nominal size )
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 505. complete in all respect. b. With hydrated lime/ cement as filler (refer table 500-9 of MoSRT&H specification) A. With 60/70 or VG-30 grade bitumen ii) for Grading II ( 19 mm nominal size )
Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.507. complete in all respect. II) With hydrated lime/ cement as filler (refer table 500-9 of MoRT&H specification) A. With 60/70 or VG-30 grade bitumen i) for Grading I ( 19 mm nominal size )
Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoRT&H cl. no.507. complete in all respect. II) With hydrated lime/ cement as filler (refer table 500-9 of MoRT&H specification) A. With 60/70 or VG-30 grade bitumen ii) for Grading II ( 13 mm nominal size )
Construction of Subgrade (Construction of sub-grade and earthen shoulder with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirements of Technical specifications) (I) Private land
7. Service Road Excavation in Soil using Hydraulic Excavator Tippers with disposal all lead and lifts. (Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3).
Granular Sub-base with well Graded Material (Table:- 400-1) By Mix in Place Method (Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical specifications clause 401) i) for grading-II Material
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate as per Technical specificationnincluding premixing the Material with water at OMC in mechanical mix plant, carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density including lighting, barricading, and maintenance of Diversion, etc as pe Table 400.11 & 400.12 andTechnical specifications clause 406 )
Prime coat (Providing and applying primer coat as per Technical specifications with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per as per Technical specification clause 502.) i) Medium Porosity
Tack coat (Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom as per Technical specification clause 503 Normal Bituminous surface
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoRT&H cl. no. 507. complete in all respect. I. With hydrated lime/ cement as filler (refer table 500-9 of MoSRT&H specification) A. With 60/70 or VG-30 grade bitumen ii) for Grading II ( 19 mm nominal size )
Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. II) With hydrated lime/ cement as filler (refer table 500-9 of MoRT&H specification) A. With 60/70 or VG-30 grade bitumen ii) for Grading II ( 13 mm nominal size )
Construction of Subgrade (Construction of sub-grade and earthen shoulder with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirements of Technical specifications) (I) Private land
Padestrain Guard Rail : Tubular Steel Railing on Precast RCC posts, 1.2 m high above ground level (Providing, fencing and erecting 50 mm dia painted steel pipe railing in 3 rows on precast M-20 grade RCC vertical posts 175 mm x 175 mm x 1.8 m high (1.2 m above Gl) with 3 holes 50 mm dia for pipe, fixed 2 m centre-to- centre complete as per approved drawings Clause 1706
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the inneredge of the service road constructed with M-40 grade concrete with HYSD reinforcement and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design and approved drawing and at locations directed by the Engineer.
8. Drain Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) i) Ordinary soil B a)Mechanical Means, with dewatering upto 3 m depth
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. a) PCC Grade M15
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser( Masterplast ACPL or equivalent) conforming to IS-9103-1999. C. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
9. Parking Area Development PCC 1:3:6 in Foundation (Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification clause 802,803,1202 & 1203. With crushed stone-PCC grade M10-Nominal mix 1:3:6
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202.
Plain/reinforced cement concrete in substructure completed as per drawings and technical specification Clauses 802,804,805,806 with crushed stone-For height upto 5m . RCC grade M 25
10. Traffic Signage and Others Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2.0 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and signs(All steel work must be Tata/Sail/or any other approved brand). i) 90 cm equilateral triangle
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2.0 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and signs(All steel work must be Tata/Sail/or any other approved brand). iii) 60 cm circular
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2.0 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and signs(All steel work must be Tata/Sail/or any other approved brand). v) 60 cm x 45 cm rectangular
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2.0 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and signs(All steel work must be Tata/Sail/or any other approved brand). vii) 90 cm high octagon
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701)
Retro-Reflectorised Traffic Signs RCC Pipe Delineator Providing of hume pipe delineator, 250 mm in diameter, 1250 mm high, having 25mm skin thickness filled with earth for stability up to 5 cm from top and remaining filled with 1:3:6 c.c.in spherical segment to prevent percolation of water and emeded in c.c. (1:3:6) below ground level up to a depth of 500mm, 75mm thick cc surrounding the pipe, painted white as per approved drawing. d) Object hazard marker
Street Lighting (Providing and erecting street light mounted on a steel circular hollow pole of standardn specifications for street lighting, 10-12m high spaced 30 m apart, 1.8m overhang on oneside fixed on the footpath, fixed with 40W Solar panel lamp and fixed on the concrete foundation.)
Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, eff lorescence and applying paint @ of 1 litre for 2 Sq.m. A) For Plain surface
Road Marking with Hot Applied Thermoplastic Compound Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Road Stud with Lense Reflector Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.
11. Proof Check: Carrying out Proof Checking of all structural drawing & design by IIT (G)
Raju Mesh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid