Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.7 LAccepted-AOC | 1 | Accepted-AOC BEING L1 | |
| 2 | 2₹26.9 L+₹3.4 L (14.6%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 2 | Rejected-Finance BEING L2 | |
| 3 | 3₹28.7 L+₹5.2 L (22.1%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | 3 | Rejected-Finance BEING L3 | |
| 4 | 4₹31.7 L+₹8.2 L (34.9%)Rejected-Finance MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 4 | Rejected-Finance BEING L4 | |
| 5 | 5₹32.0 L+₹8.4 L (35.9%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | 5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
28 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UDHAMPUR
GE AF UDHAMPUR
REFER NIT AND TENDER DOCUMENTS
2023_MES_577847_1
GE/AFU-69/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE AF Udhampur
REPAIR/ REPLACEMENT TO UNSV
LT CABLE, LT ACSR CONDUCTOR, LINE LIGHTENING, INSULATORS, LT POLE AND
POLE SHIFTING, LT AERIAL BUNCHED CABLE (ABC), TREE TRIMMING/ CUTTING/
PRUNNING ETC AND CERTAIN ALLIED WORKS AT AF STATION UDHAMPUR
UNDER GE (AF)
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹80,000
Yes
16 Mar 2023
30 Jan 2023
2 Mar 2023
30 Jan 2023
28 Feb 2023
15 Feb 2023
30 Jan 2023 - 7 Feb 2023
Amount
Excavation in trenches in any type of soft / hard soil, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation / laying of pipes/ laying of cable etc and getting out. Complete all as specified and directed by Engr-in-Charge.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm. Complete all as specified and directed by Engr-in-Charge.
Removing excavated material (soils) not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point. Complete all as specified and directed by Engr-in-Charge.
M & L for Sand cushioning for 8 cm before laying the cable and then after laying the cable 15 cm width of trenches for protection of cables including punning down complete all as specified. Complete all as specified and directed by Engr-in-Charge. Note :- Thickness of sand cushioning shall be measure 18 cm after punning down.
Supply and fixing of Brick common burnt clay building /ducts bricks’ sub-class `B’ Designation 75 (230 x 115 x 75 mm) .Complete all as specified and directed by Engr-in-Charge.
S&F in repair 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
S&F in repair 50 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed by Engr-in-Charge.
S & F in repair GI tubing 40 mm bore light grade, as in protection pipe for passing through cable etc fixed on wall/poles or laid in trenches/ducts or across road including necessary clamps required complete all as specified directed by Engr-in-Charge.
Painting to steel tubular swaged poles 9/11 mtr long complete (except above the perimeter wall portion) including all MS work mounted on pole, earth protection & with pipe (if exists) with one coat of aluminium paint and synthetic enamel paint from top of perimeter wall / PCC coping and numbering of poles with white synthetic enamel paint on black back ground complete all as specified and directed by Engr-in-Charge
Supply and Laying XLPE Cable insulated screened PVC bedded galvanized steel strips or wire armoured, (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, laid in under floors/ roads or on walls complete including taking down old complete all as specified and directed by Engr-in-Charge of following sizes :- Note Item No 10.01 to Item No 10.10. (i) Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles, Clamps, fastner,nut,bolt and washers etc rates shall deemed to be included in the quoted rates). (ii) No credit shall be given and no recovery on account of credit shall be made to contractor when new cable is laid and old cable is not retrieved on available.
10 sqmm 4 core
16 sqmm 4 core
25 sqmm 3.5 core
35 Sqmm 3.5 core
50 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
150 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V,thermal magnatic load, ICS = 100% of ICU, 63 Amps with breaking capacity 16 KA including all accessories all as specified and directed by Engineer-in Charge. Make : Schneider / Havells/L&T/Standard/Legrand or its equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, thermal magnatic load, ICS 100% of ICU, 100 Amps with breaking capacity 16 KA including all accessories all as specified and directed by Engineer-in Charge. Make : Schneider /Havells/L&T/Standard/Legrand or its equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 250 Amps with breaking capacity 35 KA as per IEC60947-2 including all accessories all as specified and directed by Engineer-in Charge. Make : Schneider / Havells/L&T/Standard/Legrand or its equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 400 Amps with breaking capacity 35 KA as per IEC60947-2 including all accessories all as specified and directed by Engineer-in Charge. make Schneider ,cat part No LV516343/Havells/L&T/Standard/Legrand or equivalent as approved by GE.
Disconnecting and taking down old unserviceable MCCB of any description and capacity and Material and labour for MCCB 4 Pole, 415 V, adjustable type,thermal magnatic load, ICS 100% of ICU, 0.8 ln to 1 ln, 630 Amps with breaking capacity 50 KA as per IEC60947-2 including all accessories all as specified and directed by Engineer-in Charge. Make : Schneider / Havells/L&T/Standard/Legrand or its equivalent as approved by GE.
Trimming of tree in vicinity of electric supply pole/street light pole/solar modules & depositing at places n exc 50m complete all as specified and directed by Engineer-in-Charge.
M&L for Arial Bunched cable 1.1 KV grade, stranded and compact aluminium phase conductor of size 35 sqmm, 3.5 core and 25 sqmmx 1 core (bare messenger/conductor) with aluminium alloy. The phase conductor should be insulated with XLPE Sioplas compound as per IS:14225-1995 Part-II complete all as specified and directed by Engineer-in-Charge. Note :- The rated quoted shall be deemed to include the cost of fittings such as anchor clamps, suspension clamps, in line connectors, service clamps, insulation piercing connectors, tapping from bare lines etc. and nothing extra shall be admissible on this account.
Disconnecting and taking down old unserviceable ATS of any description and capacity and Supply and fixing of Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1 four pole ,AC -31A,50 Hz,415 Volts of capacity 315 Amps automatic /manual with inbuilt time delay with enclosure complete including fixing the ACB in the panel by cutting/drlling, nut, bolts and washers etc shall deemed to be included in the quoted rate all as directed and specified by the Engr-in-Charge. Make : Havells ,cat part No. IHYFCDE315 or its equivalent as approved by GE.
Disconnecting and taking down old unserviceable ACB of any description and capacity and supply and fix Air circuit breaker 4 Pole, 415V, Fixed Type with microprocessor based ET2B trip unit of capacity 800 Amps with breaking capacity 50 KA as per Conforms to IEC/EN : 60947-2, IS-13947-2, ICS=100% of ICU, Icw=50 kA 1 sec, Ui = 1000V ,Uimp=12KV, Frequency = 50/60 Hz, cat B complete all as specified and directed by Engineer-in Charge. Make :Schneider cat part No.SPS08F4PMF2B, Havells/L&T/Legrand etc or its equivalent as approved by GE
Disconnecting and taking down old unserviceable Al Conductor of any description and capacity and Material and labour for fixing the Aluminium conductor, steel reinforced on the poles and tightening the conductor complete all as specified and directed by Engineer-in Charge
Disconnecting and taking down old unserviceable insulator of any description and capacity and Supply and fix shackle type, porcelain, vitreous, white, brown or green insulator of size 75 mm and dia 90 mm including one galvanised mild steel straps of size 31 x 3 mm, two galvanised iron washers and one galvanised iron bolts of dia 12 mm for 1100 volts grade complete all as specified and directed by Engr-in-Charge.
Disconnecting and dismantling the electrical connection and shifting of Lt Panel boards by disconnecting incoming and outgoing cable including all accessories including nut, bolt, washer and thimble etc complete and refixing of the Lt panel on staging by embedding the panel legs minimum 30 cm in ground/staging and adding a layer of PCC 1:2:4, 100 mm thick and re-connecting base of panel shall be atleast 45 Cm from ground level. All metal work like provn of glands, civil work etc shall be deemed to be included in quoted rates all as specified and directed by Engr-in-Charge.
Disconnecting and taking down old unserviceable bus bar chamber/Lt panel of any description and capacity and Supply and fixing of Wheather proof outdoor, Lt panel ,made out of 3.15 mm thick MS sheet comprising 4 Nos copper bus bar strips each of 400 amps ,45 cm long duly insulated on insulators including incomming MCCB 200 amps 25 kA, Ics = 100% Icu, adjustable thermal & adjustable megnetic settings with spreader links, copper reducer etc 01 Nos and outgoing MCCB 100 amps 16 kA, Ics = 100% Icu, 02 Nos, TP 63 Amp 10 KA, C Curve = 01 Nos, complete with 4 nos mounting legs made out of 50 mmx50mmx6 mm angle iron grouted in PCC block of size 30cmx30cmx90cm (30cm depth below ground level and 60 cm above ground level) in cement concrete 1:3:6 ,type C-2 (using 40 mm grade crushed stone aggregate),and connection with size of aluminium thimbles,nuts,bolts and washers including Set of three LED lights RYB, complete internal wiring with suitable size of copper wire, digital voltmeter, ammeter, CT of ratio 50/5 of 3 nos and cable glands at entry and outlets points including excavation and earth work,returning filling and removal of surplus soils ,including taking out old unserviceable bus bar chamber complete all as specifiedand directed by Engineer -in -charge.
M&L for Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with copper earth plate earth electrode 60 cm x 60 cm x 3.15 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8 m below normal ground level connected to and including cupper earthing strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 50mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc, and provision of brass/copper nuts, bolts washers etc wherever required and making jointsas required 20x3 copper strip coplete all as specified and directed by Enginer-in-Charge.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
S&F in repair Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed.
S&F in repair heat shrinkable End termination jointing kits and accessories of following capacities and type:- Note for item No 29.01 to 29.03 :- Rate for the execavation, returing filling and removing of the earth work and provide labour and Electrician shall deemed to be included in the quoted price, not extra be paid for this items.
Outdoor/indoor 120 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 95 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
S&F in repair heat shrinkable straight through joint kit and accessories of following capacities and type:- Note for item No 30.01 to 30.03 :- Rate for the execavation, returing filling and removing of the earth work and provide labour and Electrician shall deemed to be included in the quoted price, not extra be paid for this items.
Straight through joint kit indoor/outdoor al conductor cable of size 120 to 150 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor al conductor cable of size 35 to 50 Sqmm and 3.5/4 core
Straight through joint kit indoor/outdoor al conductor cable of size 95 Sqmm and 3.5/4 core
S&F in repair off LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed.
S&F in repair off LOAD change over switch 415 V in sheet metal enclosures 4 pole of capacity 200 Amps complete all as specified and directed.
Supply only rubber boot 9 Nos suitable for 33 KV line with all accessories (full pvc dual density high ankle gum boots (12 " height ) as specified and directed by Engr-in-Charge.
S&F in repair 150 watt LED flood light, with IP 66 protection, PF≥0.90, lumen efficiency ≥130 Lm/Watt, 5700 k engergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to rough services /installation & having surge protection upto ≥ 5 KV complete as specified and directed Make- HPL cat part No HPLLEDFL15060F or its equivalent /Wipro/Crompton as approved by GE
S&F in repair flood light 60 watt LED, 5700 K flood light engergy saving, environmental friendly long life exclusive innovative die cast aluminium flood light with high power led as light source suitable for highlighting architectural feature or area lighting also suitable to PF ≥ 0.90, lumen efficiency ≥100 Lm/Watt & surge protection ≥ 5 KV, rough services /installation incl taking down old one etc complete as specified and directed Make- HPL cat part No HPLLEDFL06060F/Wipro/Crompton or equivalent approved by GE
S&F for clamps made of 40 x 6 mm flat iron including nuts bolts, washers etc complete all as specified and as directed.
S&F in repair Bracket made out of 40 mm bore dia steel water tubing, light grade of over all length 1.20 metre including bending to shape and fixed to pole with and including mild steel clamps, bolts and nuts of appropriate size and shape as approved by Engineer-in-Charge complete all as specified and as directed
M&L for type B1 1:2:4 (20 mm graded aggregate) Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed by Engineer-in-Charge.
M&L for type C2 1:3:6 (40 mm graded aggregate) cement concrete in foundation and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Battery Trolly angle iron heavy duty (20mmx20mmx3mm) of size 80 cm length and width 40 cm and height 50 cm complete all as specified and directed.
Cleaning the each sub station in side and out side building/fencing/two/four pole structure ,and also around 2 m radius out side the fencing every three month duly taking out unwanted material grass/vegitable/roots of tree/small tree etc complete as specified and directed
M&L for spraying the chemical (Roundup) in sub station in the ration 1: 3 (1 litre chemical and 3 litre water) for buring the grass complete all as specified and directed by Engr-in-charge.
M&L for Weather proof outdoor bus bar chamber wall mounted, made out of MS sheet comprising of Copper strips each of 200 Amps, 4 way,appx 60cm long duly insulated mounted on insulators including complete with all accessories and connections with copper thimbles, nuts, bolts & washers including cable glands at entry and outlet points including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge. Make :-Havells cat part No IHBC020004 or its equivalent as approved by GE.
M&L for Weather proof outdoor bus bar chamber wall mounted, made out of MS sheet comprising of Copper strips each of 200 Amps, 8 way,appx 60cm long duly insulated mounted on insulators including complete with all accessories and connections with copper thimbles, nuts, bolts & washers including cable glands at entry and outlet points including taking out old unserviceable bus bar chamber complete all as specified and directed by Engr-in-charge. Make :-Havells cat part No IHBC020008 or its equivalent as approved by GE.
S&F in repair Aluminium Lugs of size 16 sqmm complete all as per specified and directed by Engr-in-Charge.
S&F in repair Aluminium Lugs of size 35 sqmm complete all as per specified and directed by Engr-in-Charge.
S&F in repair Aluminium Lugs of size 185 sqmm complete all as per specified and directed by Engr-in-Charge.
Disconnecting and dismantling the electrical connection and shifting of electrical poles by disconnecting incoming and outgoing cable including all accessories complete and refixing the pole by excavation, returning & filiing and removal of any type of soil including PCC 1:3:6 type C-2 with using 40 mm graded crushed stone aggregate as in foundation and PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping etc complete all as specified and directed by Engr-in-Charge
Repair/maint and overhauling of L.T.Panel 3 phase AC 415V, 50 Hz A of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp meter, phase indicator LED lamp,Change over switch of any capacity ,burnt out copper winding ,current coil ,potential coil and keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of parts including removal of old paint with 02 coat synthetic enamel machine spray paint after 01 coat iron red oxide machine spray paint along with replacement of unsv nuts, bolts, thimbles, gasket etc as per site requirement including denting, welding and replacement of unsv hinges if requirement complete testing all as specified and directed by Engineer-in-Charge. Note : (a) All spare parts and control wiring will be measured and paid seperately under respective item of Sch 'A'. are as under. (b) Denting, welding, replacement of unsv hinges, locking arrangement, handle, unsv gasket, cable gland, nut, bolt, washer, minor repair of PCC foundation if required and removing of old paint alongwith reassembling, testing, commissioning etc shall be deemed included into the quoted rate.
MCB TPN, 'C' series capacity 32 Amps, 415V, 50 c/s 16 KA . Make : Legrand / Schnieder / L&T
MCB SPN capacity 32 Amp, 'C' series-02 Nos Make : Legrand / Schnieder / L&T
Set of indicating lamp LED type-01 Set.
Civil work PCC 1:2:4 for grouting of panel complete Size- (0.25x0.25x0.25 cum x 04) including excavation, earth work.
Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 25 mm x 3 mm
Copper insulated bus bar with DMC/porcelain insulator etc made out of laminated as per existing size 50 mm x 6 mm
Current transformer of suitable size as per existing
Copper wiring 1.5 Sqmm as per existing size
M & L for Rab Aldrop in L Shape of Galvanised Iron with Pad Lock not less than 6 liver all as specified and directed by Engr-in-Charge. Make :- Harrison/Godrej or equivalent .
M & L for CRCA MS Sheet of any size alongwith fixing arrangement through nut, bolts or welding etc suitable for panel base plate or panel canopy all as specified and directed by Engineer-in-Charge. Note :- (i) Rate include for making the hole in the gland according to the size of cable and re-connecting the cable in the existing panel etc. (ii) Size of sheet shall be as decided and directed by Engineer-in-Charge.
M & L for Heat shrinkable sleeves of size 10 to 35 Sqmm complete all as specified and directed by Engr-in-Charge.
M & L for Heat shrinkable sleeves of size 50 to 95 Sqmm complete all as specified and directed by Engr-in-Charge.
M & L for Heat shrinkable sleeves of size 120 to 240 Sqmm complete all as specified and directed by Engr-in-Charge.
Laying under ground cables/Re-routing only LT UG cable of size 10 sqmm x 2,10 sqmm x 4 core to 185 sqmm x 3.5 core cable shall be provided under Sch 'B' or the existing overground and laying cable along with connection with LT panel/Pole or Other electrical equipment with proper thimble/Aluminium lugs and making good complete all as specified and as directed by Engr-in-Charge. Note :- (i) Execavation / Returning / Filling / cable protection and sand cushioning shall be measured and paid separately. (ii) Quoted rate shall be inclusive of cutting cable/jointing of cable, provision of thimbles, lugs, cable gland for connection of cable IN / OUT from Panels/Feeder Piller Boxes/Bus bar as per Site requirement. (iii) The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed. (iv) Extra use of cable shall be measured & paid separately in case of non availability of EM store.
DAVINDER SINGH
ANIKET TRADERS
RANBIR ENTERPRISES
MOHAN LAL AND SONS
MAHAJAN TRADING CO
PARAS RAM ASGOTRA AND SONS
KARAN TRADERS
ASIA BUILDER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .