Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹15.4 L
Closing Date
29 Jun 2026, 2:30 pmClosed
4 TYPES OF SET OF SIDE WALL COMPLETE,ROOF ASSEMBLY & END WALL COMPLETE FOR VANDE METRO
05261306~RCF
05261306
Open - Indigenous
Goods
Garhwa, Jharkhand
₹0
₹15.4 L
29 Jun 2026
27 May 2026
Description :SET OF SIDE WALL COMPLETE,ROOF ASSEMBLY & END WALL COMPLETE FOR TS VANDE METRO DTC NOTE:-(1) WHEREVER RAW MATERIAL MENTIONED AS ASTM A 666-10 TYPE 201LN ? HAR D IS NOT TO BE USED.IN PLACE OF ABOVE GRADE, RAWMATERIAL TO RDSO SPECIFICATION CK-201 (X CrNi12) IS TO BE USED. (2) Side wall assly to be manufactured as per Design letter no. MD48131 date d 22/05/2025, as per Drawing: MP23VBDTC VERSION 4, Packing Instruction: RETURNABLE & RE-USABL E METALLIC PALLET ITEM SHOULD BE SUPPLIED IN RETURNABLE & RE-USABLE PALLET MADE OF STEEL . THE DESIGN OF THE PALLET SHOULD BE : " WATER AND FIRE PROOF. " RUST FREE. " HAVING GOOD STRENGTH TO WEIGHT RATIO. " SUITABLE FOR STACKING IN SEVERAL LAYERS, COMPATIBLE WITH EACH OTHER WHEN STACKED. " ABLE TO WITHSTAND THE ROUGH HANDLING OF COMMON LOGISTIC SYSTEMS SUCH AS FORK LIFTER, CRANES ETC. " ABLE TO FACILITATE THE STORING, HANDLING AND U NLOADING WITH MINIMUM LABOUR AND TIME. " HAVING THE INTERIOR OF THE PALLET LINED WITH S UITABLE MATERIAL (LIKE FRP ) SO AS TO PREVENT DAMAGE TO THE ITEM BEING TRANSPORTED. WHIL E STACKING THE ITEM INSIDE THE PALLET, THERE SHOULD BE MINIMUM USE OF DISPOSABLE PACKING . " THE PALLET SHOULD HAVE FIRM'S LOGO FOR IDENTIFICATION. FIRM SHOULD ALSO INDICATE PL NO ., DESCRIPTION OF ITEM ON THE PALLET. NOTE : 1.FOR PACKING THE INDIVIDUAL ITEM(S), THE USE O F MATERIAL WHICH ARE NOT ENVIRONMENT FRIENDLY SUCH AS WOOD/POLYETHENE/PLASTIC IS PROH IBITED, HOWEVER THE ENVIRONMENT FRIENDLY PLASTIC CAN BE USED. 2.THE ITEM SHOULD BE PACK ED IN SUCH A WAY THAT IT SHOULD NOT RUB DURING TRANSPORTATION. THE IN-TRANSIT DAMAGE, I F ANY, SHALL BE AT COST OF THE SUPPLIER. 3.THE DESIGN TO BE GOT APPROVED BY THE FIRM FROM CDE/RCF BEFORE INITIATING MANUFACTURING. [ Warranty Period: 30 Months after the date of deliv ery ] ] Consignee SHELL DEPOT, RCF Punjab 4.00 Set Inspection Stage Inspection Not Required Details
STORES/TKJ/RCF Description :SET OF SIDE WALL COMPLETE,ROOF ASSEMBLY & END WALL COMPLETE FOR TS VANDE METRO MC,MC2 & MC3 NOTE:-(1) WHEREVER RAW MATERIAL MENTIONED AS ASTM A 666-10 TYPE 20 1LN ? HARD IS NOT TO BE USED.IN PLACE OF ABOVE GRADE, RAWMATERIAL TO RDSO SPECIFICATION CK-201 (XCrNi12) IS TO BE USED. (2) Side wall assly to be manufactured as per Design letter no. MD4
RE-USABLE METALLIC PALLET ITEM SHOULD BE SUPPLIED IN RETURNABLE & RE-USABLE PALLET MADE OF STEEL. THE DESIGN OF THE PALLET SHOULD BE : " WATER AND FIRE PROOF. " RUST FREE. " HAVIN G GOOD STRENGTH TO WEIGHT RATIO. " SUITABLE FOR STACKING IN SEVERAL LAYERS, COMPATIBLE WITH EACH OTHER WHEN STACKED. " ABLE TO WITHSTAND THE ROUGH HANDLING OF COMMON LOG ISTIC SYSTEMS SUCH AS FORK LIFTER, CRANES ETC. " ABLE TO FACILITATE THE STORING, HANDLING AND UNLOADING WITH MINIMUM LABOUR AND TIME. " HAVING THE INTERIOR OF THE PALLET LINED WITH SUITABLE MATERIAL (LIKE FRP ) SO AS TO PREVENT DAMAGE TO THE ITEM BEING TRANSPORTE D. WHILE STACKING THE ITEM INSIDE THE PALLET, THERE SHOULD BE MINIMUM USE OF DISPOSABLE PACKING. " THE PALLET SHOULD HAVE FIRM'S LOGO FOR IDENTIFICATION. FIRM SHOULD ALSO INDICA TE PL NO., DESCRIPTION OF ITEM ON THE PALLET. NOTE : 1.FOR PACKING THE INDIVIDUAL ITEM(S), T HE USE OF MATERIAL WHICH ARE NOT ENVIRONMENT FRIENDLY SUCH AS WOOD/POLYETHENE/PLASTI C IS PROHIBITED, HOWEVER THE ENVIRONMENT FRIENDLY PLASTIC CAN BE USED. 2.THE ITEM SHOUL D BE PACKED IN SUCH A WAY THAT IT SHOULD NOT RUB DURING TRANSPORTATION. THE IN-TRANSIT DAMAGE, IF ANY, SHALL BE AT COST OF THE SUPPLIER. 3.THE DESIGN TO BE GOT APPROVED BY THE FIRM FROM CDE/RCF BEFORE INITIATING MANUFACTURING. [ Warranty Period: 30 Months after the date of delivery ] ] Consignee SHELL DEPOT, RCF Punjab 16.00 Set Inspection Stage Inspection Not Required Details
Description :SET OF SIDE WALL COMPLETE,ROOF ASSEMBLY & END WALL COMPLETE FOR TS VANDE METRO TC NOTE:- (1)WHEREVER RAW MATERIAL MENTIONED AS ASTM A 666-10 TYPE 201LN ? HARD I S NOT TO BE USED.IN PLACE OF ABOVE GRADE, RAWMATERIAL TO RDSO SPECIFICATION CK-201 (XCr Ni12) IS TO BE USED. .(2) Side wall assly to be manufactured as per Design letter no. MD48131 dated 22/05/2025.., as per Drawing: MP23VBTC VERSION 4, Packing Instruction: RETURNABLE & RE-USABLE METALLIC PALLET ITEM SHOULD BE SUPPLIED IN RETURNABLE & RE-USABLE PALLET MADE OF STEEL. THE DESIGN OF THE PALLET SHOULD BE : " WATER AND FIRE PROOF. " RUST FREE. " HAVING GOOD S TRENGTH TO WEIGHT RATIO. " SUITABLE FOR STACKING IN SEVERAL LAYERS, COMPATIBLE WITH EAC H OTHER WHEN STACKED. " ABLE TO WITHSTAND THE ROUGH HANDLING OF COMMON LOGISTIC SYS TEMS SUCH AS FORK LIFTER, CRANES ETC. " ABLE TO FACILITATE THE STORING, HANDLING AND UNL OADING WITH MINIMUM LABOUR AND TIME. " HAVING THE INTERIOR OF THE PALLET LINED WITH SUIT ABLE MATERIAL (LIKE FRP ) SO AS TO PREVENT DAMAGE TO THE ITEM BEING TRANSPORTED. WHILE S TACKING THE ITEM INSIDE THE PALLET, THERE SHOULD BE MINIMUM USE OF DISPOSABLE PACKING. " THE PALLET SHOULD HAVE FIRM'S LOGO FOR IDENTIFICATION. FIRM SHOULD ALSO INDICATE PL NO., DESCRIPTION OF ITEM ON THE PALLET. NOTE : 1.FOR PACKING THE INDIVIDUAL ITEM(S), THE USE OF MATERIAL WHICH ARE NOT ENVIRONMENT FRIENDLY SUCH AS WOOD/POLYETHENE/PLASTIC IS PROHIBITED, HOWEVER THE ENVIRONMENT FRIENDLY PLASTIC CAN BE USED. 2.THE ITEM SHOULD BE PACKED IN SUCH A WAY THAT IT SHOULD NOT RUB DURING TRANSPORTATION. THE IN-TRANSIT DAMA GE, IF ANY, SHALL BE AT COST OF THE SUPPLIER. 3.THE DESIGN TO BE GOT APPROVED BY THE FIRM F ROM CDE/RCF BEFORE INITIATING MANUFACTURING. [ Warranty Period: 30 Months after the date of delivery ] ] Consignee SHELL DEPOT, RCF Punjab 8.00 Set Inspection Stage Inspection Not Required Details
STORES/TKJ/RCF Description :SET OF SIDE WALL COMPLETE,ROOF ASSEMBLY & END WALL COMPLETE FOR TS VANDE METRO NDTC NOTE:-(1) WHEREVER RAW MATERIAL MENTIONED AS ASTM A 666-10 TYPE 201LN ? HARD IS NOT TO BE USED.IN PLACE OF ABOVE GRADE, RAWMATERIAL TO RDSO SPECIFICATION CK-20
dated 22/05/2025., as per Drawing: MP23VBNDTC VERSION 5, Packing Instruction: RETURNABLE & RE- USABLE METALLIC PALLET ITEM SHOULD BE SUPPLIED IN RETURNABLE & RE-USABLE PALLET MADE OF STEEL. THE DESIGN OF THE PALLET SHOULD BE : " WATER AND FIRE PROOF. " RUST FREE. " HAVING GOOD STRENGTH TO WEIGHT RATIO. " SUITABLE FOR STACKING IN SEVERAL LAYERS, COMPATIBLE WI TH EACH OTHER WHEN STACKED. " ABLE TO WITHSTAND THE ROUGH HANDLING OF COMMON LOGIST IC SYSTEMS SUCH AS FORK LIFTER, CRANES ETC. " ABLE TO FACILITATE THE STORING, HANDLING AN D UNLOADING WITH MINIMUM LABOUR AND TIME. " HAVING THE INTERIOR OF THE PALLET LINED WIT H SUITABLE MATERIAL (LIKE FRP ) SO AS TO PREVENT DAMAGE TO THE ITEM BEING TRANSPORTED. W HILE STACKING THE ITEM INSIDE THE PALLET, THERE SHOULD BE MINIMUM USE OF DISPOSABLE PACK ING. " THE PALLET SHOULD HAVE FIRM'S LOGO FOR IDENTIFICATION. FIRM SHOULD ALSO INDICATE PL NO., DESCRIPTION OF ITEM ON THE PALLET. NOTE : 1.FOR PACKING THE INDIVIDUAL ITEM(S), THE US E OF MATERIAL WHICH ARE NOT ENVIRONMENT FRIENDLY SUCH AS WOOD/POLYETHENE/PLASTIC IS P ROHIBITED, HOWEVER THE ENVIRONMENT FRIENDLY PLASTIC CAN BE USED. 2.THE ITEM SHOULD BE PACKED IN SUCH A WAY THAT IT SHOULD NOT RUB DURING TRANSPORTATION. THE IN-TRANSIT DAMA GE, IF ANY, SHALL BE AT COST OF THE SUPPLIER. 3.THE DESIGN TO BE GOT APPROVED BY THE FIRM F ROM CDE/RCF BEFORE INITIATING MANUFACTURING. [ Warranty Period: 30 Months after the date of delivery ] ] Consignee SHELL DEPOT, RCF Punjab 4.00 Set Inspection Stage Inspection Not Required Details
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
5787047.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .