Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC METHOPARA GANGANAGAR KOLKATA 700132 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700132 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹57.0 L+₹7.8 L (15.9%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹59.8 L+₹10.6 L (21.6%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹64.0 L+₹14.8 L (30.1%)Rejected-Finance NUTANCHATI BHOWMIK GATE BANKURA | BANKURA | L4 | Rejected-Finance 4th lowest |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
29 Nov 2021, 12:30 pmClosed
EE/BED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
Arrangement of proposed 24 bed Hybrid Critical Care Unit at Bankura Sammilani Medical College and Hospital, Bankura-- Electrical Installation work
2021_WBPWD_350999_1
WBPWDTE/EE/BED/NIQ_134/Q of 2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1.4 L
17 May 2022
16 Nov 2021
1 Dec 2021
16 Nov 2021
29 Nov 2021
16 Nov 2021
Amount
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/ LT/ Havells of the following sizes as to GS 8 way Enclosure upto 160 Amp ( Normal Power - 2 no, UPS- 2 no , AC Machine-2 no )
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/ LT/ Havells as to GS. 8 way Enclosure ( Normal Power - 6 nos, UPS- 4 nos , AC Machine-2 nos )
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/ LT/ Havells as to GS 2+12 way Enclosure ( Normal Power - 8 nos, UPS- 2 nos , AC Machine-2 nos )
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment Make-Legrand/ Siemens/ LT/ Havells as to GS. 8 way
Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection Make-Legrand/ Siemens/ LT/ Havells, as to GS. 160 Amp ( for VTPN)
125 Amp (for Incoming & outgoing side of the UPS )
Supplying and fixing MCCB SS enclosure with IP-20/30 protection, powder coated provision for four pole MCB/MCCB , concealed in wall after cutting the wall & mending good the damages to original finish/ on flat iron frame incl. painting, connection & provision for earthing attachment. 4 Way
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/ LT/ Havells as to GS. 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/ LT/ Havells as to GS. 6A - 32A SP MCB
63A TP MCB
S & F 415 Volt, following rated sheet steel enclosure on load TPN front operated change over switch Make L&T/ Siemens/HPL fixed on angle iron frame on wall as per direction of EIC 125 A ( for UPS)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire ( Finolex / Havells/ KEI / Gloster /approved by EIC) through PVC trunking / cable tray/ in 20mm size PVC rigid conduit 'FR' (Precision make) on wall / partly concealed as per requirement at site & direction of EIC, with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/ fan / call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. “Ph & N” copper bar ncl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. Average run 10 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire ( Finolex / Havells/ KEI / Gloster /approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish . On Board
Supply & Fixing 240 V, 2 x 20A, plug socket with separate 2 nos x 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( Computer Board )
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 20 0x 65mm MS (16SWG) switch board and bakelite / perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 4 nos. 20A plug socket with separate 4 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (approved make) on sheet metal switch board embedded in wall incl. S & F 300 x 200 x 65 mm MS (16SWG) switch board and bakelite/ perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in suitable sizes ( 40 / 32 / 25 mm ) PVC rigid conduit 'FR' (Precision make) incl. necessary fittings as required / through PVC trunking / cable tray/ on wall / partly concealed as per requirement at site & direction of EIC 2 x 1.5 sq mm + 1 x 1.5sq mm (for separate plug )
2 x 2.5 sq mm + 1 x 1.5sq mm ( for computer board, Power plug , Fan motor of AC unit )
2 x 4 sq mm + 1 x 2.5 sq mm (for AC )
2 x 6 sq mm + 1 x 4 sq mm ( from TPN MCB DB to SPN MCB DB s , AC Machine , Power Board )
4 x 10 sq mm + 2 x 6 sq mm (for Centrifugal Cabinet Type Fan )
4 x 25 sq mm + 2 x 16 sq mm (for 40 KVA UPS )
Supplying of following sizes Al. armoured PVC/XLPE (Havells/ Glostar/ KEI/ approved ) as per direction of EIC 4 core 35sqmm ( from VTPN to MCBPBDB & Panel to UPS)
4 core 70 sqmm ( from Panel to VTPN )
4 core 185 sqmm ( from MCH Bldg to DG Panel and Existing panel near Sub Station to new panel )
Supplying & fixing of hanger on wall / on MS structure as per requirement at site and laying of cable with 3 tire arrangement appx 24'' long as per appvd drawing and the cable hanger made with MS angle 50 mm x 50 mm x 5 mm painting with 2 coats of RO primer and one coat of appvd. Paint with grouting on wall by fastener system / fixing arrangement at MS structure with clamping or welding as per requirement incl scaffolding arrangement if reqd.to complete the installation as per direction of EIC
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.(With 25 x 25 x 3 mm angle iron support) 300 x 50 x 125 mm (18 SWG)
Supplying & Fixing of Maxi Trunking & Fittings from High Impuct unplasticised polyvinyl chloride UPVC grade as per IS 14927 Part 2 and BS : EN 50085 - 2 -1 ( Precision / AKG make ) on wall / ceiling incl necy. PVC fittings etc. and Product code PT 100100 of 100 mm x 100 mm in size also mending good the damages to original finish as per direction of EIC
Laying of following sizes Al. armoured PVC/XLPE cable surface on wall / on wall by clamp / concealed as reqd. with with 2 x 10 SWG GI wire as per direction of EIC upto 3.5/4 core 35 sqmm to 50 sq mm with 2 x 10 SWG GI wire
upto 3.5 / 4 core 70 sqmm to 3.5/4 core 150 sq mm with 2 x 10 SWG GI wire
Laying of cable From 70 sq mm to 185 sq mm on existing Cable Tray/ on hanger and binding with suitable size GI wire & clamp as per direction of EIC .
Laying of one No. cable upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 35 sq mm
4 core 70 sq mm
4 core 185 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 35 sq mm
4 core 70 sq mm
4 core 185 sq mm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
Supply of 250 V 50 HZ 16" (400 mm) high flo oscillating type metal body Wall Bracket fan operated by pull cord switch with inbuilt regulator ( Make -CG/Orient/Approved)
Fixing of high flo oscillating type metal body Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC
Supplying & Fixing angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC
Supplying & Fixing 3 way Ceiling Rose fixed on ceiling / wall and terminated the distribution wiring for the uses of projector & sound system at training hall as per direction of EIC
Supplying & Fixing 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Havelles make cat No. REGALBATTENT8 1x22WSSBSWH (With 5 years warranty)corresponding to Wipro / Bajaj / Crompton suspended bellow the false ceiling with necy fixing arrangement by spl. tppe clamp etc and if the fittings fixing on wall then necy fixing arrangement by spl. tppe clamp on wall are necessary to complete the same with supports & MS clamp etc incl painting and mending good the damages to original finish as per direction of EIC
Supplying & Fixing 4 feet twin commercial LED type fluorescent light fittings complete with all accessories with 2 x 20 Wt.Master LED Tube lamp similar to Havelles make cat No. REGALBATTENT8 2x22WSSBSWH (With 5 years warranty) corresponding to Wipro / Bajaj / Crompton suspended bellow the false ceiling with necy fixing arrangement by spl. tppe clamp etc and if the fittings fixing on wall then necy fixing arrangement by spl. tppe clamp on wall are necessary to complete the same with supports & MS clamp etc incl painting and mending good the damages to original finish as per direction of EIC
Supplying & Fixing 250 V AC/DC superior type Call Bell (Anchor-8320) on HW board incl. S&F HW board
Supply & Fixing exhaust fan (Make -- EPC, Heavy duty) of following sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia incl. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS 12" (30 cm) 1420 RPM
Taken down the following existing fittings from its original position & storing properly incl . handed over the same at Section Store of B.S.M.C&H El. Sec as per direction of EIC Single / Twin tube fitting (various type ) / Ceiling fan / Exhaust fan
Fixing only single/twin fluorescent light fittings ( taken from existing position ) suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp (125mmx125mm) as per G S ( materials supplied by Dept )
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing of 250V 50 HZ OLP- 21A single phase A.C Starter ( Make -Electron, / PWD Appvd ) suitable for 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying & Fixing Industrial Plug & Socket board with 415 V, 63A, 4-Pole-3P+N+E Metal Industrial Plug socket & 63A Industrial top(Legrand Cat no.-5078 64 or equivalent model of Siemens/ABB) incl. S&F 63 A FP MCB(Legrand DX-series or equivalent model of Siemens/ABB) of breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and necessary connection.
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex/ PWD appvd ) of suitable size comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one no 415V, 40 Amp TPN MCB etc. conceal in wall as per direction of EIC ( for TFA & AC Mahine )
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex/ PWD appvd ) of suitable size comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one no 230V, 32Amp DP MCB etc. conceal in wall as per direction of EIC ( for fan )
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 100 mm dia
Cutting the hard road for instllation of GI pipe and mending good the damages as per direction EIC
The panel should be installed as per site condition & requirement with brick pedistal / foundation etc and neat cement finish the total foundation ( appx 1'6" to 2' from ground level ) and other arrangement with temorary power suurce from the existing panel with out hampering the patient care service by his own arrangement / materials and after all no additional cost or no extra cost will be paid by the department after completion the installation also considering loading , unloading , shifting etc in shafe place to complete the job as per site condition & direction of EIC
Supply and Fixing of sign board acrylic signages i) Supply and fixing of angle iron frame fabricated from 40 mm x 40 mm square four nos hollow bar with cross and radial support including one no 40x40 mm angle iron support in the middle for the Sign board of following size with suitable three nos. crosss angle support welded with 4 nos angle hook in equal space for fixing on the structure with all necessary welding and fabrication. The structure shall rest in both sides with proper welding as per instruction of EIC. ii) S&F LED Sign Board made 3 mm thick ACP Sheet (Alstrong/ Aludecor) finished with approved metallic colour as back ground (blue) after router cutting. The riser structure also shall be covered with ACP Sheet.& appx 6-7 inch depth (Both size ACP sheet) iii) S&F Special type of imported acrylic English letter appx 50 mm thickness flushed on the ACP board made on imported acrylic ACAST sheet. The mater appvd by EIC letter font shall be in horizontal line as mentioned. iv) S&F SMD LED inside the board and to run for each letter including wiring , soldering etc and fixing the SMPS properly with the specification of the SMD 1.LED colour : White/ Red/ Blue (make-samsung /Nichia /Cree/ Hisine ) 2.Stright : 2 or 3 nos LED per module 3. Luminous Flux : 140 LUMEN 4. Life : 70000 burning hours 5. Visibility: 100 meter atleast normal eye 6. Power Supply: 1.2 watt to1.6 watt per module 7.Input : 230A.C , Output : 12V DC 8.Shape of LED : recrangle or square 9. Grade : IP - 65 v) S & F LED Power supply 300/ 400W IP65 50/60Hz frequency, 108 to 305 VAC driver power supply other electrical accessories the panel prepared along with its necessary arrangement ( make Hisine/Migion/Cehosa/PWD appvd ) vi) Cost of painting of MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping with emery paper properly make ICI/Asian paints vii) Cost of erection of scaffolding for fixing the Signage viii) Testing and commissioning of the LED board as per following nomenclature
Supply & Fixing of 16 SWG GI Sheet in the back side of Sign board and fixing the sheet on the structure with all necessary welding and fabrication. as per instruction of EIC
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.( 2 nos in each Panel & 1 no in each UPS)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.( for UPS)
Supplying & fixing of PVC heat shrinkable sleeve / Insulated sleeve for the total galvanized MS flat Earth bus as per direction of EIC
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.( for Panel )
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
Dismentling the existing E.I. work incl existing defective , non functioning Panels , PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC and at the time of dismentling the existing Electrical accessories for the renovation work the agency must have follow the following points and after all no additional cost or no extra cost will be paid by the department after completion the installation ------ i) the agency must have arrange the temorary power source to VTPN, PBDD, LBDB etc from the existing panel at the time of renovation work by his own arrangement / materials with out hampering the patient care service . ii) Room for staying labour / Site office / Store for materials etc are not available by our department at the time of renovation work and the agency must have arrange by his own . iii) the agency must have clean the site as per requirement by his own arrangement for better patient care service iv) Working time are available in consultation with Hospital authority with out hampering / disturbing the patient care service .
RS SYSTEMS AND PROJECTS
Mars Developments
PRADIP KUMAR DHABAL
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .