Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.1 L+₹2.4 L (5.84%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹43.1 L+₹2.4 L (5.97%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹47.5 L+₹6.8 L (16.8%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹50.0 L+₹9.3 L (22.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
12 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO-GARHI, PIN-182121
Spl Repairs/ Replacement to E/M Assets at Medical Complex under GE (Utilities) Udhampur
2024_MES_684058_1
GE/U- -2024-25
Open Tender
Miscellaneous Works
Item Rate
90 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹96,000
17 Jan 2025
14 Nov 2024
19 Dec 2024
14 Nov 2024
12 Dec 2024
28 Nov 2024
Amount
Shifting of 400 KVA 11/0.433 KV Transformer from CHNC old location to new location by dismantling all electrical connections with the help of crane and commissioning and testing at the same at new said location with the help of crane, complete all as specified and directed by Engr in Charge.
Description all as per Ser item No 1.00 here-in-before but for 500 KVA Transformer, complete all as specified and directed by Engr in Charge.
Shifting of 320/250 KVA DG Set from CHNC old location to new location by dismantling all electrical connections with the help of crane and commisioning and testing the same at new said location with the help of crane, complete all as specified and directed by Engr in Charge.
Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in Hard/dense soil and getting out, complete all as specified and directed by Engr in Charge.
Description all as per Ser item No 4.00 here-in-before but exceeding 1.5 mtr deep but not exc 3.0mtr deep, complete all as specified and directed by Engr in Charge.
Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engr in Charge.
Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed by Engr in Charge.
Supply and Fixing for galvanised iron tubing 100 mm dia light grade with all fitting laid under floor/road crossing or in trenches or fixed to pole /walls with with clamps as required including sealing of pipe ends with apporoval sealing compound etc, complete all as specified and directed by Engr in Charge.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 300 Sqmm and laid in trenches/ducts/pipe or on poles, complete all as specified and directed by Engr in Charge. Make : Havells/Polycab/Grandlay
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 185 Sqmm and laid in trenches/ducts/pipe or on poles, complete all as specified and directed by Engr in Charge. Make : Havells/Polycab/Grandlay
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 11000 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3 core X 120 Sqmm and laid in trenches/ducts/pipe or on poles, complete all as specified and directed by Engr in Charge. Make : Havells/Polycab/Grandlay
M&L for heat shrinkable type end termination joint kit outdoor type suitable for XLPE insulated HT cable 11000 Volts grade of size 120 to 185 Sqmm 3 core complete with jointing material and acessories alongwith testing after jointing including taking out the old unserviceable joint kit, complete all as specified and directed by Engr in Charge.
Supply, Installation , testing and commissioing outdoor type, weather proof, cubicle panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15 x 15 x 15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/ openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliset for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry. The panel shall accomodate the following equipments, complete all as specified and directed by Engr in Charge :-
INCOMING (a) MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 630 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. OUTGOING (a) MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 320 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos. (b) MCCB 4 Pole, Ics = 100% Icu,25/26KA, 415 Volts, 200 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 03 Nos. (c) MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 125 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 03 Nos. (d)MCCB 4 Pole, Ics = 100% Icu, 35/36 KA, 415 Volts, 250 Amps, with thermal adjustable and fixed magnetic setting with extended terminals - 01 Nos.
Supply, Installation , testing and commissioing outdoor type, weather proof, cubicle panel board made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle, embedded in PCC 1:2:4 type B-1 blocks of size 15 x 15 x 15 cm front and back openable, double door openable up to minimum 150 degree & removable type having magnetic catche system, lockable/ openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable foamed in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliset for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produced to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels complete suitable cable glands for cable entry. The panel shall accomodate the following equipments, complete all as specified and directed by Engr in Charge :-
Material and labour for earthing complete with galvanised earth plate electrode 600mm x 600mm x 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 32x6 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion, complete all as specified and directed by Engr in Charge.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost
M & L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground, vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at depth of not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI wire 4 mm by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer ( including making of test point with GI Strip of size 32x6mm) including GI protection pipe 15 mm med grade dia for protection of strip upto test point all as directed GI pipe medium grade 15 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggregates complete including excavation and earth work, all as specified and shown in plate No 3 of SRR-1991 Part-1, PCC pit shall be provided at least 50cm away from the earth pit and not just on earth pit, complete all as specified and directed by Engr in Charge. (Note for Ser Item No. 15.00 & 16.00:- The unit rate include earthing lead and protection pipe up to 7.50 metre from top of earth plate)
M&L Earth continuity conductor fixed to wall or pole from test point to GOD switchfor loop earthing etc with GI strip of size 32 x 6 mm, complete all as specified and directed by Engr in Charge.
Supply & fixing switch air break gang operated, vertical type triple pole, mechanically operated, mounted on insulator and steel frame with operating machanism worked from ground level using heavy duty GI pipe, for current rating 400 Amp, outdoor type (conforming to IS specifications) HT 11 KV, triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse assembly, fuse carrier fitting, 12 insulator type mounted on MS channel operating rod with pad lock arrangement, complete all as specified and directed by Engr in Charge.
Supply and Fix lightining arresters expulsion type complete with all fittings suitable for 11000 volts grade conforming to IS-3070 part-I, transmission class, discharge capacity 65 kilo amp, complete all as specified and directed by Engr in Charge.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc, complete all as specified and directed by Engr in Charge.
M&L for cement concrete (1:3:6) type B-1 using 20mm graded stone aggregate as coping of pole and strut, stay around the pole etc, complete all as specified and directed by Engr in Charge.
M&L for Steel tublar HT pole and Supply, transportation upto site of work and erection of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) and including marking alternate 05 Nos white and black strip 30cm height with two coats of synthetic enamel paint all as specified. (Excavation and earth wok and PCC for foundation, channel, clamps nuts, bolts to be measured and paid separately), complete all as specified and directed by Engr in Charge.
M&L for Material and Labour for construction of plateform for transformer 2.5m (wide)x 2.5m (long) & 1.5m (height) including moorum filling, earth work in brickwork any type of soil, brick work in CM (1:6) and PCC at top 10 cm thick (1:2:4) type B-1 and foundation with 1:4:8 type D-2, 25cm thick all as per drawing including plastering to exposed walls and white wash, providing MS channel on top of size 75x40x8mm of 1.5m length for rolling to transformer, including chain link fencing of wire mesh 150x100 size made out 4mm dia GI wire of height 1.5m fixed with the help of MS strip 25x6mm on and including MS angle iron 75x45x6mm thick 12 Nos post by the means of drilling holes at the distance of 30cm and fixed with the help of suitable nut, bolt and washer, the length of MS angle iron not less than 2.25m top of post bend to the shape of 60 degree including 03 Nos cuts for inserting barbed wire including 03 run of barbed wire and including provision of gate of size 1.5mx0.9m made out of MS angle iron 50x50x6mm and MS bar 12mm dia for meshing to the gate and locking arrangement complete all necessary for work, complete all as specified and as shown on drawing No. CEUZ/TD/1516/15 sheet 1/1, complete all as specified and directed by Engr in Charge.
M&L for Material and Labour for construction of plateform for DG set 320 KVA 3.0m (wide)x 5.0m (long) & 0.6m (height) including moorum filling, earth work in brickwork any type of soil, brick work in CM (1:6) and PCC at top 10 cm thick (1:2:4) type B-1 and foundation with 1:4:8 type D-2, 25cm thick all as per drawing including plastering to exposed walls and white wash, complete all as specified and directed by Engr in Charge.
M&L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts and wasters,welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide primer and two coats of aluminum paint, complete all as specified and directed by Engr in Charge.
Supply and lay DWC ( Double wall corruated ) pipe 180 x 152 mm conforming to IS 14930/ IS 16205 for protection of LT / HTCable of size 300 sqmm including neccesory Snap-Fit cuppler required for fixing, complete all as specified and directed by Engr in Charge.
Supply and fixing in On load change over switch with Sheet Steel Enclosure 415 V, 4 pole, 630 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cables from LT panels to change over switches, complete all as specified and directed by Engr in Charge.
ANIKET TRADERS (BID ID -3187414)
FANGALIA TRADERS (BID ID -3178151)
MOHAN LAL AND SONS (BID ID -3180726)
PREM NATH KHAJURIA AND SONS (BID ID -3185959)
K S BUILDERS (BID ID -3178065)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .