Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
19 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
ADDN ALTN TO BLDG NO P 721 P 724 IN A ZONE ADDN ALTN OF TOILET NEAR BLDG NO T 34 35 BCD JCO LIVING TOILET IN M ZONE AND ADDN ALTN OF TOILET BLOCK AT BLDG NO T 4 BCD IN I ZONE
2025_MES_730907_2
8911/C/E8
Open Tender
Civil Works
Item Rate
180 days
RANGAPAHAR
Class D
Category a(i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹86,000
1 Nov 2025
1 Nov 2025
21 Nov 2025
1 Nov 2025
19 Nov 2025
6 Nov 2025
1 Nov 2025 - 4 Nov 2025
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc. 15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8 mm thick area of each tile exceed 0.18 sqm but not exc 0.38 sqm ,as in floor etc. set and jointd in neat cement slurry and pointed in white or coloured cement to match the shade of tiles , laid over and including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM (1:4)complete all as specified and directed.
M&L for Non skid ceramic coloured tiles of 7 to 8mm thick light colour (Square / rectangular) ,area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors laid over and including 15mm thick screed bed for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles etc complete all as specified and directed.
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed GI grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size and finally applying two coats of oil bound distemper etc complete all as specified and directed.
Each Set
S&F mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm, fixed with tinned tacks or galvanized wire staples complete all as specified and as directed
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling & fixing in opening complete all as specified and as directed
M & L rendering 15mm thick in cement mortar (1:4) on brick or concrete work finished the surface even and smooth without using extra cement including taking down old plaster complete all as specified and as directed.
M & L rendering 15mm thick in cement mortar (1:4) on brick or concrete work finished the surface even and smooth without using extra cement complete all as specified and as directed.
M & L rendering 15mm thick in cement mortar (1:6) on brick or concrete work finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer of surface exc. 10cm width or girth complete all as specified and as directed.
M&L 15mm thick plastering in CM (1:4) on one side of lathing in two separate layers without using extra cement but using water proofing compound @ 3% by wt of cement and surface finished even and smooth including demolition of reed, lathing single or double, including battens and plaster or chicken wire lathing with and including M&L for GI wire netting 0.71 mm dia and 12 mm mesh lathing in to reed in walls incl all laps cutting and waste complete all as specified and as directed. Note:-WPC will be measured and paid separately.
M&L for rendering 12 mm thick in CM (1:6) on other side of lathing surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E 250) quality-A complete all as specified and as directed
M&L for precast cement concrete type B-1 (1:2:4) (Using 20 mm graded stone aggregate) as in cover slabs, manhole cover, chamber cover and drainge cover set in cement mortar 1:6 including necessary formwok complete all as specified and as directed.
M&L for second class hardwood as in scantlings clean sawn timber fixed including dismantling of old unsv timber scantlings etc complete all as specified and as directed.
M&L for brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exc 6 m mean radius in CM (1:4) complete all as specified and directed.
M&L for preparation of new wall surface and two coats of cement base paint over a coat of primer on walls complete all as specified and as directed.
M & L Vitreous china ware wash down water closet pan (EWC), pedestal pattern coloured including plastic WC seat black closd pattern eith flat bottom and cover and mild steel chro
M&L for applying two coats of oil bound distemper over a coat of primer over a coat of 2mm thick wall care putty(in two layers) on new plastered surfaces of walls including preparation of new surface complete all as specified and directed.
M&L for applying one coat of oil bound distemper on old plastered surfaces of wall complete all as specified and as directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails,braces,etc.,complete drilled for fixing of steel sheeting or other covering.Doors,etc.to be prepared for hanging or sliding with and hinges or steel hanging door fitting
mium plated of aluminised hinging device, complete fiting complete all as specified and as directed. .
S&F Aluminium alloy anodised sliding door bolt with hasp and staple (bolt type fixing clips of sheet cast or extruxded section(300 mm long) complete all as specified and directed.
M&L for preparation of old wall surface and applying one coat of cement base paint on walls complete all as specified and as directed.
M&Lfor mild steel TMT bars 6 mm to 8 mm dia cut to length, bent to shape reqd incl cranking, bending and binding with MS wire n.exc 0.90 mm dia (annealed) for stirrups/binders complete all as specified and as directed.
Material and labour for (concelaed Type) point wiring including necessary chases cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) PVC sheathed multistranded copper conductor cable 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit with all accessories and sunk GI box for mounting of fittings like switch, socket and fan regulator etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge
One light point controlled by one, one way switch .
One Ceiling fan/ exhaust fan point controlled by one, one way switch.
S&F MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
S&F MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
S&F MCB SPN 40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
S&F MCB SP 5-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
S&F MCB TPN 63 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with blades, and frame and louvers complete all as specified and as directed.
Supply and fixing Wall mounted fan 400 mm sweep PP Blade and thermal overload protection for long lasting motor power consumation 58 Watt fan motor speed 1330 RPM Air dilivery 85 (CMM) with accessories complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed.
M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: Punned down thickness shall be measured and paid.
Supply & laying tubes ' light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking down corroded GI tubing complete all as specified and as directed.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 4 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
Tender8911.pdf
Tender Documents • 1.67 MB
BOQ_826451.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .