The Registrar
Admin Building, IIITDM Kancheepuram
Providing and Fixing Aluminium Partition Works in Various Laboratories (L114, L012, L011, L009, L007, L312, L514, L417, L316A, L011C and L513) at IIITDM Kancheepuram
2026_IITDM_935192_1
IIITDMK/2026-27/ENGG/CIVIL/009
Open Tender
Civil Works
Item Rate
90 days
IIITDM Kancheepuram
As per eNIT
7 documents required · 7 mandatory
₹0
₹2.0 L
Admin Building, IIITDM Kancheepuram
20 Nov 2026
20 Nov 2026
14 Dec 2026
20 Nov 2026
11 Dec 2026
30 Nov 2026
26 Nov 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing, fabricating and fixing anodised aluminium framed partitions, including fixed panels, single-leaf doors, double-leaf doors and sliding/openable door shutters, wherever required, using extruded aluminium sections conforming to IS 1285, with 100 × 45 × 2.5 mm sections for vertical and horizontal framing of fixed partitions. Vertical members shall be spaced at a maximum of 0.90 m centre-to-centre, and horizontal members shall be provided at bottom, 1.20 m, 2.10 m and top levels, including additional intermediate horizontal members wherever the panel height above 2.10 m exceeds 0.90 m. The vertical framing members shall be rigidly fixed at both floor and ceiling/beam soffit, as applicable to site conditions, using 50 × 50 × 3 mm thick L-angle cleats with suitable approved fasteners including providing and filling the gap between ceiling/wall and the aluminium frame with silicon sealant etc.. The work shall include providing and fixing 12 mm thick pre-laminated particle board conforming to IS 12823, Grade I, Type II, laminated on both sides, in designated solid portions, and 5 mm thick float glass weighing not less than 12.50 kg/sqm in designated glazed portions, generally between 1.20 m and 2.10 m levels, securely fixed with suitable EPDM/neoprene gaskets and aluminium snap beading. | |||||
| 1.1 | Door/shutter frames shall be fabricated using 100 × 45 × 3.0 mm aluminium sections, generally 2.10 m high and minimum 0.90 m wide per single-leaf doorway, with 12 mm thick pre-laminated particle board up to 1.20 m height and 5 mm thick float glass above up to 2.10 m height. The work shall include providing and fixing 125 mm aluminium handles, 250 × 10 mm aluminium tower bolts, mortice locks, hydraulic door closers, 150 mm brass floor door stoppers, 300 × 16 mm MS sliding door bolts, 125 × 75 × 4 mm aluminium butt hinges, sliding G-channels with 25 mm diameter rollers, wherever applicable, together with aluminium clips, cleat angles, CP brass/stainless steel screws, dash fasteners, weather-grade silicone sealant with backer rod and all necessary fittings, fixtures, hardware and accessories. All aluminium sections shall be anodised with a minimum anodic coating of Grade AC-15 conforming to IS 1868. The quoted rate shall include cutting, drilling, machining, fabrication, fixing, erection, alignment, finishing, wastage, scaffolding, conveyance, loading, unloading, labour, tools, equipment and all incidental works, complete in all respects as per approved drawings, actual site conditions and directions of the Engineer-in-Charge. Measurement shall be made on the basis of the overall finished elevation area in square metres, including doors and shutters forming part of the partition system. Approved Makes: Aluminium – Jindal/Hindalco ; Pre-laminated Particle Board – Century/GreenPly ; Glass – Saint-Gobain/AIS/ModiGuard ; Hardware – Dorma/Crown/Sigma/Godrej. | - | - | - | - |
| 1.2 | The above work shall be carried out at the following laboratory locations: L312 – Library, 2nd Floor Physics Lab, measuring 18.60 m × 3.00 m (55.80 sqm), with double door; L312, measuring 4.70 m × 3.30 m (15.51 sqm), with double door; L011-11C, measuring 6.50 m × 3.80 m (24.70 sqm), with single door; L514, measuring 15.50 m × 3.80 m (58.90 sqm), with sliding door; L007, measuring 25.00 m × 3.80 m (95.00 sqm), with double door; L009, measuring 17.00 m × 3.80 m (64.60 sqm), with double door; L011, measuring 15.00 m × 3.80 m (57.00 sqm), with double door; L112, measuring 26.00 m × 3.80 m (98.80 sqm), with double door; L114, measuring 57.00 m × 3.80 m (216.60 sqm), with double door; L417 (Bird Lab), measuring 8.23 m × 3.80 m (31.27 sqm), with sliding door; L316A, measuring 7.80 m × 3.80 m (29.64 sqm), with sliding door; and L513, comprising two partition sections measuring 5.00 m × 3.80 m (19.00 sqm) and 23.85 m × 3.80 m (90.63 sqm), both with sliding doors. The total estimated partition area shall be 857.45 sqm, including all specified doors and shutters. The quantities and dimensions are tentative and shall be verified at site before fabrication. The number, location, configuration and opening direction of all doors shall be finalised in consultation with the Engineer-in-Charge. The quoted rate shall be inclusive of all materials, partition framing, laminated boards, glazing, doors, shutters, sliding mechanisms, hardware, fittings, fixtures, installation, finishing, transportation, labour and all incidental charges, complete in all respects. No separate payment shall be made for doors, shutters, door frames or associated accessories, and payment shall be based on the actual finished partition area executed and measured at site. | 858 | sqm | 1.25 | ₹1,072.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_982735.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .