Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC KARAIKAL | KARAIKAL | PUDUCHERRY | 609601 | ₹8.5 L Quoted ₹9.1 L | L1 | Accepted-AOC Lowest |
Tender Value
₹8.1 L
EMD Value
₹16,133
Closing Date
14 Mar 2023, 3:30 pmClosed
Executive Engineer
The Executive Engineer, Irrigation and Public Health Division, PWD Karaikal
Supply, Erection and Commissioning of 82.5 KVA Genset at OHT Campus in Thirunallar
2023_PWDC3_12202_1
30-02/IPH/TN/2022-23
Open Tender
Electrical Works
Item Rate
30 days
Karaikal
Please refer Tender documents.
2 documents required · 2 mandatory
₹525
₹16,133
17 Apr 2023
7 Mar 2023
14 Mar 2023
7 Mar 2023
14 Mar 2023
7 Mar 2023
Amount
Supplying of 3.5x120 sqmm underground cable (Paragon/suncab/Empire) complete.
Laying of UG cable and providing termination of cable joint with suitable cable gland,cable socket etc., complete - 3.5 x 120 sqmm cable.
Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos of 12mm dia. holes, pipe lowered in bore holes of 150mm dia. and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround,covered with R.C.C. precast slab etc. as per I.E. standards.
Supplying and fixing of copper flat (25 x 3mm) for earthing arrangements including bolts and nuts etc.
Laying of under ground cable direct in ground including metal road cutting,excavation of earth, sand cushion, brick protection, back filling etc., complete. - above 50 sqmm
Supplying of 3 phase, 415 volts, 50 cycles, 0.8 power factor for electric starting diesel generator comprising the following units (Kirloskar/ Leyland/Ruston/Greaves Cotton/Cummins make) water cooled and shall be of multi stroke, multi cylinders, cold starting, developing not less than105BHP under normal temperature and pressure. The engine shall conform to I.S. 10002 with latest amendments. It shall be capable of taking 10% over load for one hour in every 12 hours of continous operation including 6 Nos. of anti vibration pads.The engine shall be complete with the following accessories:Electrical starting provision, engine cooling fan, fuel and lubricating oil filters, oil bath, air filter, lub oil pressure gauge 200 litres capacity fuel tank mounted with engine, hour meter with exhaust manifold, flexible pipe, 12 /24 volts electric starting equipment complete with starter, alternator and one number of 12 volts with 21 plates battery of make AMCO/ STANDARD/ EXIDE/DAGANITE (with Guarantee cards) of adequate capacity and low lubricating oil pressure/high temperature varying engine shut down devices.The Acoustic enclosure shall have the following: Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet.
The silent canopy shall be of nut bolt type construction. Powder coating is done after seven tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam/Rock Wool as acoustic material. Four hinged doors shall be provided to canopy, one door shall have glass window for control panel.Base frame is fabricated either in ISMC channel or in sheet metal. The base frame is rugged in construction and designed for mounting engine and alternator, with cross members mounted on AVM. The base frame shall have
provision for mounting of acoustic enclosure and it is having provision of lifting hook for convenient lifting of complete set, i.e. along with canopy, engine and alternator.Fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections of suitable capacity.The Acoustic enclosure shall be Type test approved as per CPCB norms. The average sound level, when measure in green field condition (ISO m3744 OR 8528 PT 10) at 1-meter distance from all four sides shall be less than 75-dBA average or as per CPCB norms. The average stabilized hot air temperature rise with in the canopy is maintained with in 10 C over and above ambient temperature.Acoustic enclosure is suitable for Outdoor / Indoor installation. Lockable doors shall be provided. Lockable fuel filling arrangement to be provided external to the canopy. Residential Silencer is housed in the canopy. The exhaust gasses shall be taken out through a suitable flexible pipe to prevent any back pressure on the engine.Base frame sturdy, fabricated welded construction, channel iron / sheet metal base frame for mounting the above engine and alternator.Standard Tools and Spares:Double ended spanners complete set (small and big size sets) - 12 Nos. (TAPARIA/GEDORGE/EVEREST make)Screw driver (30cm long) Taparia make .Screw driver (45cm long) Taparia make .Cutting plyer.Diesel filter with elements - 2 Nos.Oil filter with elements - 1 No.
Providing and fixing of fire safety equipments comprising 1 No. of 4.5 kg of CO2 fire extinquisher 1m x 2m x6mm thick rubber mat shock proof of superior quality with two numbers of 10 litres capacity fire buckets (red colour) with M.S. stand arrangements etc.
Charges for transporting, erection, testing and commissioning of generator set excluding foundation,but including mechanical and other unskilled wages for installation of equipment, wiring from generator set to panel board and change over switches, handling charges, purchase of spares if any required for the installation and commissioning, the cost of fuel and other materials for a trial run of 6 hours. This rate also includes for testing and commissioning of generator set as specified, obtaining approval of Central Electricity Authority (CEA), payment for CEA inspection/Licence fees or any other charges and fulfilling other requirements and conditions laid down by CEA-From 62.5 / 63 KVA to 100 KVA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .