| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC | ₹2.6 Cr | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER |
| 2 | L2₹2.7 Cr+₹15.5 L (5.99%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹2.7 Cr+₹15.5 L (5.99%) | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 3 | L3₹2.8 Cr+₹18.9 L (7.31%)Rejected-Finance 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹2.8 Cr+₹18.9 L (7.31%) | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 4 | L4₹2.8 Cr+₹22.0 L (8.50%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | ₹2.8 Cr+₹22.0 L (8.50%) | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| 5 | L5₹2.9 Cr+₹27.1 L (10.5%)Rejected-Finance 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | ₹2.9 Cr+₹27.1 L (10.5%) | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | United Sales Corporation L6 | UNICON L1 | vishalconstruction L5 | UNIQUE ENGINEERS L4 | Mehta Construction Co. L3 | S.R.M.K Enterprises L9 | Horizon Construction L2 | L.K.R.TIWARI CONSTRUCTION L7 | KHANDELWAL ASSOCIATES L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out / removing old water proofing treatment and cleaning the surface of slab and clearing with wire brushes, removing dust, fungus, moss small plants etc from the slab and removing the rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. | 4,000 | Sqm | 175 ₹7,00,000 | 9 ₹36,000 | 20 ₹80,000 | 24 ₹96,000 | 10 ₹40,000 | 50 ₹2,00,000 | 9 ₹36,000 | 22 ₹88,000 | 4.5 ₹18,000 Lowest |
| 2.00 | M&L for rendering 10mm thick in CM 1:3 on RCC roof slab mixed with liquid water proofing compound as per manufacturers instructions finishing even and smooth without using extra cement to receive water proofing treatment complete all as specified and as directed by Engineer-in-Charge
Note :-Liquid WPC shall be measured and paid separately under relevant item of this BOQ. | 4,000 | Sqm | 175 ₹7,00,000 | 135 ₹5,40,000 | 90 ₹3,60,000 Lowest | 240 ₹9,60,000 | 100 ₹4,00,000 | 250 ₹10,00,000 | 99 ₹3,96,000 | 100 ₹4,00,000 | 126 ₹5,04,000 |
| 3.00 | M&L water proofing treatment over RCC slab by applying oil based bitumen primer @ 0.25 kg/Sqm and providing and laying 3 mm thick APP (Atactic Poly Propylene) bitumen membrane modified water proofing polymetric membrane with 100mm side and end lap having weight not less than 3.50kg/sqm, reinforced with non woven polyester reinforced matt weighing not less than 160gms/sqm polyester core having soften point not less than 1500C, longitudinal tensile strength not less than 650N/5cm, by torching method and applying a coat of solar reflective aluminium paint @0.15 Kg/Sqm on membrane surfaces complete including carrying out 24 hrs ponding test complete all as specified and as directed by Engineer-in-Charge.
Note:- Tenderer shall get the work of waterproofing treatment to RCC roof slab through manufacturer or through their approved applicator only. | 4,000 | Sqm | 350 ₹14,00,000 | 345 ₹13,80,000 Lowest | 350 ₹14,00,000 | 455 ₹18,20,000 | 365 ₹14,60,000 | 500 ₹20,00,000 | 405 ₹16,20,000 | 380 ₹15,20,000 | 405 ₹16,20,000 |
| 4.00 | Supply only liquid water proofing compound | 78.8 | Litre | 50 ₹3,940 | 140 ₹11,032 | 100 ₹7,880 | 225 ₹17,730 | 100 ₹7,880 | 150 ₹11,820 | 45 ₹3,546 Lowest | 80 ₹6,304 | 63 ₹4,964.4 |
| 5.00 | Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. | 7,140 | Sqm | 15 ₹1,07,100 | 48 ₹3,42,720 | 20 ₹1,42,800 | 50 ₹3,57,000 | 30 ₹2,14,200 | 50 ₹3,57,000 | 9 ₹64,260 Lowest | 45 ₹3,21,300 | 18 ₹1,28,520 |
| 6.00 | M & L for non skid ceramic coloured tiles , 7 to 8 mm thick (square or rectangular) area of each tile exc 0.11Sqm but n.exc 0.18 Sqm, laid in floors set and jointed with neat cement slurry including pointing in white cement with pigment to match with the shade of tiles and laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and as directed by Engineer-in-Charge. | 400 | Sqm | 675 ₹2,70,000 | 875 ₹3,50,000 | 800 ₹3,20,000 | 800 ₹3,20,000 | 645 ₹2,58,000 Lowest | 900 ₹3,60,000 | 810 ₹3,24,000 | 880 ₹3,52,000 | 720 ₹2,88,000 |
| 7.00 | M&L for Glazed ceramic coloured tiles on vertical surface 600x300x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles including 10 mm thick cement plaster 1:4 as in backing coat complete all as specified and as directed by Engineer-in-Charge. | 1,100 | Sqm | 725 ₹7,97,500 Lowest | 1,115 ₹12,26,500 | 1,000 ₹11,00,000 | 850 ₹9,35,000 | 1,000 ₹11,00,000 | 1,000 ₹11,00,000 | 900 ₹9,90,000 | 980 ₹10,78,000 | 990 ₹10,89,000 |
| 8.00 | M&L for polished digital ceramic tiles 8-9 mm thick any shade, (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles & laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. | 5,500 | Sqm | 850 ₹46,75,000 Lowest | 975 ₹53,62,500 | 900 ₹49,50,000 | 1,050 ₹57,75,000 | 875 ₹48,12,500 | 1,300 ₹71,50,000 | 900 ₹49,50,000 | 950 ₹52,25,000 | 990 ₹54,45,000 |
| 9.00 | ditto as per item no 08 but on vertical surface including 10 mm thick cement plaster 1:4 as in backing coat complete | 140 | Sqm | 900 ₹1,26,000 Lowest | 1,200 ₹1,68,000 | 1,000 ₹1,40,000 | 1,100 ₹1,54,000 | 1,100 ₹1,54,000 | 1,300 ₹1,82,000 | 909 ₹1,27,260 | 1,000 ₹1,40,000 | 999 ₹1,39,860 |
| 10.00 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as specified and as directed by Engineer-in- Charge | 255.62 | 10 Sqm | 250 ₹63,905 | 330 ₹84,354.6 | 100 ₹25,562 | 600 ₹1,53,372 | 400 ₹1,02,248 | 500 ₹1,27,810 | 99 ₹25,306.38 | 500 ₹1,27,810 | 90 ₹23,005.8 Lowest |
Tender Value
₹3.7 Cr
EMD Value
₹4.5 L
Closing Date
30 Jun 2025, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
ADD / ALTN TO BLDG P 76 UNDER GE (CENTRAL) KHADKI
2025_MES_708829_1
CWE/KKE/TOKEN-05 OF 2025-26
Open Tender
Civil Works
Item Rate
365 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE CENTRAL KHADKI
₹4.5 L
Yes
21 Aug 2025
17 May 2025
2 Jul 2025
17 May 2025
30 Jun 2025
23 Jun 2025
17 May 2025 - 2 Jun 2025
Amount
Taking out / removing old water proofing treatment and cleaning the surface of slab and clearing with wire brushes, removing dust, fungus, moss small plants etc from the slab and removing the rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 10mm thick in CM 1:3 on RCC roof slab mixed with liquid water proofing compound as per manufacturers instructions finishing even and smooth without using extra cement to receive water proofing treatment complete all as specified and as directed by Engineer-in-Charge Note :-Liquid WPC shall be measured and paid separately under relevant item of this BOQ.
M&L water proofing treatment over RCC slab by applying oil based bitumen primer @ 0.25 kg/Sqm and providing and laying 3 mm thick APP (Atactic Poly Propylene) bitumen membrane modified water proofing polymetric membrane with 100mm side and end lap having weight not less than 3.50kg/sqm, reinforced with non woven polyester reinforced matt weighing not less than 160gms/sqm polyester core having soften point not less than 1500C, longitudinal tensile strength not less than 650N/5cm, by torching method and applying a coat of solar reflective aluminium paint @0.15 Kg/Sqm on membrane surfaces complete including carrying out 24 hrs ponding test complete all as specified and as directed by Engineer-in-Charge. Note:- Tenderer shall get the work of waterproofing treatment to RCC roof slab through manufacturer or through their approved applicator only.
Supply only liquid water proofing compound
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M & L for non skid ceramic coloured tiles , 7 to 8 mm thick (square or rectangular) area of each tile exc 0.11Sqm but n.exc 0.18 Sqm, laid in floors set and jointed with neat cement slurry including pointing in white cement with pigment to match with the shade of tiles and laid over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and as directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles on vertical surface 600x300x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with the shade of tiles including 10 mm thick cement plaster 1:4 as in backing coat complete all as specified and as directed by Engineer-in-Charge.
M&L for polished digital ceramic tiles 8-9 mm thick any shade, (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles & laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
ditto as per item no 08 but on vertical surface including 10 mm thick cement plaster 1:4 as in backing coat complete
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as specified and as directed by Engineer-in- Charge
S&F 20mm thick Granite (of any type) Slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing and laid over and including 15mm screed bed of CM 1:6 complete all as specified and as directed by Engineer-in- Charge.
M&L for 20-25mm thick Machine cut cudappa stone slab as in jambs, pillars, window- cills, cooking platforms, and like laid over & including 15mm thick cement screed bed in CM 1:4 and jointed in grey cement slurry mixed with pigment to match with shade of slab rubbing , polishing complete all as specified and as directed by Engineer-in- Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations.
M&L for water proofing treatment to RCC sunken slab as under and all as specified and as directed by Engineer-in-Charge (a) Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc. (b) Form angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar along with fiber mesh (“ Dr fixit” Pidicrete URP” or equivalent make given under list of Makes. (c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bath seal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bath seal Grout” or complete all as specified and as directed by Engineer-in- Charge. Nahani traps etc to be fitted securely and the gaps around it to be grouted in the same manner. (d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bath seal Plus” or equivalent make given under list of Makes. On all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. (e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing coating “Dr Fixit Pidifin 2 K” or equivalent make given under list of Makes. can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and apply second coat after 6-8 hours and allow to dry completely.
(f) After 2 to 3 days, sunken portion shall be overlaid with a 50 mm thick concrete M-10 grade (Nominal Mix) using 12.5 mm graded stone aggregate mixed with integral WPC (Liquid) laid to slope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete M-5 grade (Nominal Mix) under sunken floor . (g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of approved makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, etc.
S&F in repairs GI pipe 40mm bore as in water spouts pipe complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge
S & F in repairs wash down water closet pedestal pattern with seat cover complete set with accessories with P or S trap including connection to drain (or outgoing pipe ) and flushing pipe, antisyphonage pipe etc complete all as specified and directed.
S&F in repair two way angle cock with flange cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed both end for iron pipe or or brass ferrule for 15 mm bore of pipe complete all as specified and as directed by Engineer-in- Charge .
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by Engineer-in- Charge
S&F in repairs vitreous china squatting pan "Orissa" pattern size 580mmx440mm white with integral foot rests excluding flushing cistern and flush pipe including provision of lime concrete bedding complete all as specified and as directed by Engineer-in- Charge
S & F in repairs PVC High/Low level flushing cistern 10 litres capacity including all fittings I.e float valve, syphon, flushpipe,brackets complete all as specified and as directed by Engineer-in- Charge
S & F vitreous china wash basin white Table top any shape size 430X375X130 mm/470x345x150mm excluding taps waste chain and plug and porcelain stopper but incl necessary brackets and CP waste coupling and other fittings complete all as specified and as directed by Engineer-in- Charge
S & F in repair Pillar cock swan neck chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered Hot Or Cold With long screwed shanks and fly nuts screwed for iron pipes 15mm bore dia complete all as specified and as directed by Engineer-in- Charge
Supply and fix in repair for Vitreous China bowl urinal flat back size 330X315X420 mm wall mounted (minimum), (excluding flushing cistern, flush pipe and waste pipe) including fitting of push cock with exiting GI Tubing fixed in repairs all as per PS complete all as specified and as directed by Engineer-in- Charge
S&F in repair 32 mm bore PVC waste pipe of approved make suitable for WHB, Urinals etc complete all as specified and directed.
S & F in repair PVC connections 15mm dia with brass nut on both ends and washers 450mm long all complete all as specified and directed.
S&F in repair Bib tap fancy type cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe complete all as specified and as directed by Engineer-in- Charge.
S&F in repair stop valve cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed both end for iron pipe or or brass ferrule for 15 mm bore of pipe complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge by Engineer-in- Charge.
S&F in repairs Fancy type Stop cock (Concealed) cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed both end for iron pipe or or brass ferrule with long shank and cup for 15 mm bore of pipe complete all as specified and as directed by Engineer-in- Charge .
S & F in repairs Brass chromium plated Shower rose 125mm size with or without swivel joints, brass arm & Flange 125mm size incl fixing to steel pipe fixed in repairs as directed.
S&F in repair Brass chromium plated towel rail 600 mm long of fixed with and including chromium plated brass screw and wooden / plastics cleats complete all as specified and directed.
M&L Urinal spreader of CP Brass for fixing with 15 mm dia pipe fixed in repairs complete all as specified and directed.
S&F in repairs Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F Chromium plated towel ring, brass body, glossy finish complete all as per of Hindware or equivalent make given under list of makes complete all as specified and as directed by Engineer-in- Charge .
S&F in repair Brass CP Wall mixer for mixing hot & cold water screwed down for pipe and fixed for 15mm bore dia of pipe complete all as specified and as directed by Engineer-in- Charge
S&F in repairs Shelf of glass Corner Shelf 6 inch fixed with and including Chromium plated brass screws and wooden/plastic/ss cleats complete all as specified and as directed by Engineer-in- Charge
S&F PVC (SWR) floor trap square type with CP grating with or without hole including provision of jointing to waste pipes of outlet 75 mm, complete all as specified and as directed by Engineer-in- Charge
S&F in repairs Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engr-in-charge.
S&F in repairs 75 mm bore Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate , complete all as specified and as directed by Engineer-in- Charge
S&F in repairs stainless steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples including necessary beading all as specified and directed by Engr-in-charge.
Cleaning the surface with wire brush, detecting sources of leakages and removing/taking down unsound treatment/surface and M&L for carrying out non-destructive waterproofing treatment to sunken portion of slab, floor and walls of bath, WC, WHB and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting, etc, with first course of injection MDI based PU foam and second course of injection PU plain all as per manufacturers instruction, etc, complete and as directed. The PU foam shall have 100% solids and solvent free, and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50. (Make: PIDILITE or equivalent make given under list of makes) complete all as specified and directed and M&L for fixing packer for hydrophobic PU foam and Sealer as per manufacturers instruction .
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tile with heavy duty tile cleaner preferably of M/S Pidilite or equivalent cleaner as approved by GE, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent make as approve by GE, curing, cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
Taking down chowkhats or with shutter (without taking off shutter from the frames) & removing from site exc. 1.5 Sqm but n. exc. 4 Sqm each etc complete all as specified and as directed by Engineer-in- Charge
Taking down chowkat or with shutter (without taking off shutter from the frames) & removing from site n.exc. 1.5 Sqm each etc complete all as specified and as directed by Engineer-in- Charge
Taking down shutters of any description exc. 1.0 sqm and not exc. 2.0 sqm each complete all as specified.
S & F factory made box type steel window composite type with double rebate pressed steel frame 80mmx60mm (peripheral) and 80mmx75mm (intermediate members) including grill using 10sqmm bar, made out of cold rolled 1.25mm thick sheet having steel window/ventilators double shutter of MS tubular section of size 50mmx20mmx1.1mm thick fixed with box type hinges including 12mmx3mm MS flat as beading for glazed and wire shutter handle of 100mm MS hollow tubular section as beading for wire and putty for glazing shutter handle of 100mm size made of z section 01 no, MS stove enamelled black tower bolt of size 120mm, 02 nos, 150mm mild steel hooks and eyes, each shutter flat iron 40mmx1.25mm and 200mm long hold fast 04 nos each window including filling with PCC M-10 grade (Nominal Mix) complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge including one shop coat of red oxide on preparation of steel surface. Note:- (i) Ref DRG NO : CESZ/TD/195 given under Particular Specifications (ii) The TD given above is for reference. (iii) Ventilator shown on drg is outside the scope of work. (iv) Detail sections/sizes shown under TD shall only be followed for manufacturing of window. (v) Size of window shall be as per site requirement.
S & F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engineer-in- Charge .
S & F, plain sheet glass 4mm thick, ordinary quality, not exc 0.50 Sqm in each pane fixed to steel window/frame with oil putty and securing pins, spring clips etc complete all as specified and as directed by Engineer-in- Charge .
S&F 105x60 mm pressed steel frames made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed all as specified and as directed.
S&F 125x60 mm pressed steel frames made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed all as specified and as directed.
M&L for PCC M-15 grade (nominal mix) using 12.50mm graded stone aggregate as in filling of pressed steel chowkat, sub base & sub floor all as specified and directed
S&F factory made 35 mm thick plain framed panelled shutter (single panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with Commercial veneered on both faces the size of rail and style as per IS-1003 ( Pt-I) kiln seasoned and Chemically pressed of 2nd class hard wood complete all as specified and as directed by Engineer-in- Charge
S & F factory made 35 mm thick glazed & skeleton shutter of 2nd class hard wood open rebated and prepared to receive gauge (divided into squares with sash bars) edges of framing plain chamfered or rounded, fitted without & fitted beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I Sec-8 clause 8.24 (a) and fitted to chowkat complete all as specified and directed by Engr-in-charge
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown on Page No. 160 of SSR 2010 part II.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F Butt Hinges medium weight cold rolled mild steel 100 mm long complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge
S&F 150mm long Aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed by Engineer-in- Charge
S & F for Aluminium anodised, barrel tower bolts of 100mm length, of extruded section and fixed complete all as specified and as directed by Engineer-in- Charge
S&F for Extruded aluminium alloy handles 150 mm, fabricated type, anodised complete all as specified and as directed by Engineer-in- Charge
S&F for mild steel sliding door bolts, plate type, with stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 300mm long complete all as specified and as directed by Engineer-in- Charge
S&F for mild steel sliding door bolts, plate type, with stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 200mm long complete all as specified and as directed by Engineer-in- Charge
Taking up or down 15 mm bore steel tubing and connections including disconnection of fittings and cleaning for refixing where required or removed from site.
Taking up or down 20 mm bore steel tubing and connections including disconnection of fittings and cleaning for refixing where required or removed from site.
Taking up or down 25 mm bore steel tubing and connections including disconnection of fittings and cleaning for refixing where required or removed from site.
Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge.
Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge.
Supplying & fixing to walls and ceiling 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed by Engineer-in- Charge
S & F 110 mm bore PVC (SWR) pipe Type B single socketed in any length with rubber ring joints laid in trenches, floor and wall including taking down old unserviceable pipe any description and any type complete all as specified.
S & F 75mm bore PVC (SWR) Pipes Type B single socketed in any length with rubber ring joints laid in trenches or in floors or wall including taking down old unserviceable pipe any description and any type complete all as specified.
S & F in repairs 75mm bore of outlet PVC (SWR) floor trap , plain with grating doom 125mm dia with waste hole of PTMT, including jointing with solvent cement .
S & F in repairs 110mm bore PVC (SWR) bends any radius with rubber ring joints all as specified and directed.
S & F in repairs 75mm bore PVC (SWR) bends any radius with access door all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal
S & F in repairs 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal
S&F in repairs 75mm bore PVC (SWR) junction single (Single T) equal or unequal.
S&F in repairs 110mm bore PVC (SWR) junction single (Single T) equal or unequal.
S&F in repairs 110mm bore PVC (SWR) vent cowl.
S&F in repairs 75mm bore PVC (SWR) vent cowl.
Supply and fix 1000 litres capacity triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position with embossment of ISI mark including dismantling and removing of old tank complete all as specified and as directed by Engineer-in- Charge .
S&F in repairs Stainless steel fancy type curtain rod 25 mm including SS brackets, decorative knobs, and including separate projected SS brackets, separate decorative knobs and including all necessary fittings such as rawl plug screws complete all as specified and as directed by Engineer-in- Charge.
Taking down cement or cement lime plaster from brick / PCC block/ stone masonry walls etc including racking out joints, hacking for key scrubbing down with water etc, complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge by Engr-in-charge .
M&L for rendering 15mm thick on block masonry surfaces or surface other than fair face of brick work or on side of lathing in cement plaster 1:6 complete all as specified and as directed by Engineer-in- Charge
M&L for preparing newly plastered surfaces of walls and applying two coat of oil emulsion distemper over a coat of alkali resistance primer complete all as specified and as directed by Engineer-in- Charge
M & L for complete removal and preparing old plastered or unplaster surfaces of wall and applying two coat of oil bound distemper complete all as specified and as directed by Engineer-in- Charge
M&L preparation of old plastered or unplastered surfaces of wall and applying two coat of cement base paint including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed by Engineer-in- Charge
M&L rendering 5 mm thick in CM 1:3 on concrete surface of ceiling & finished even & smooth without using extra cement complete all as specified and as directed by Engineer-in- Charge
M & L for rendering 10 mm thick on fair faces brick work /PCC block masonry or concrete surface of wall using cement plaster 1:4 and finished even and smooth (without using extra cement) complete
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of Alkali resistant primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engr-in-Charge.
M&L for preparing old plastered or unplastered surfaces of walls brooming down or scrap down with steel wire brushes, smoke soot, moulds, moss efflorescent salts, trading oil, greasy spot and applying three coat of white wash on ceiling complete all as specified and as directed by Engineer-in- Charge by Engineer-in- Charge.
M&L for applying wall care putty not less than 1 mm thick on wall over plastered surface to prepare the surface even and smooth including one coat of primer complete all as specified and directed by Engr-in-Charge.
M&L preparation of new steel surfaces of any description exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in- Charge.
M&L preparation of old painted steel surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in- Charge.
M&L preparation of new wooden surfaces of any description exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in- Charge.
M&L preparation of old painted wooden surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in- Charge.
M&L for 20-25 mm thick machine cut machine polished Kota stone flooring and jointed with grey cement slurry mixed with pigment to match with shade of kota stone and laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all specified and directed.
M&L Mirror polishing on Kota stone work to give high gloss finish complete all specified and as directed.
Ditto as per ser No 96 but on step riser skirting over and including 10mm thick rendering in CM 1:4 complete. Note:- Kota stone slab in single piece shall be used in steps
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for and removing the demolished concrete to low laying area out side the premises complete all as specified and directed (below or above GL)
M&L for 75 mm thick PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate as in Plinth protection complete all as specified and directed
Cutting chases, pinning & making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in stone/ concrete block walls complete.
M&L for providing 25 mm thick Cement concrete M-15 grade (Nominal Mix) using 20 mm graded stone aggregate in level course for receiving floor tiles complete all as specified & directed
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation etc or for manholes, laying pipes etc and getting out in hard / dense soil.
Demolition of precast concrete block walling built in cement mortar as in manhole including PCC coping complete all as specified and directed .
Demolition of reinforced cement concrete manhole covers n. exc. 15cm thickness below or above Ground level.
M&L for cement concrete M-10 grade (Nominal Mix) using 40 mm graded coarse aggregate as in concrete bed to drain pipes including packing under & hunching against sides of pipes after they are laid and tested for 200 mm complete all as specified and as directed.
M&L cement concrete M-7.5 grade (Nominal Mix) using 40 mm graded coarse aggregate in foundations filling & mass concrete complete all as specified
M&L for reinforced concrete pipes, 200 mm bore, Class NP-2, laid and jointed complete with collars.
M&L for Precast cement concrete block masonry using type C1 1:3:6 (20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar1:6 complete
M&L for PCC M-15 grade (Nominal Mix) using 20 mm graded coarse aggregate in coping including necessary formwork and benching in bottom of manholes drain etc complete all as specified and directed..
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto all as per item No.111.
Returning, filling, including spreading levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge.
Removing excavated soil n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point.
M&L for precast cement concrete M-15 grade (Nominal Mix) using 20 mm graded coarse stone aggregate in cover slab set in CM 1:6 complete all as specified and directed.
M&L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bend to shape required, including cranking, bending and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Cutting existing GI water pipe line 50/80 mm dia in position for inserting tee/specials for branch connection of 50 mm size complete all as directed.
M&L for Laying in trenches/fixed to wall galvanised steel water tubing 25 mm bore, medium grade with and including all medium grade fittings complete all as specified.
M&L for Laying in trenches/fixed to wall galvanised steel water tubing 40 mm bore, medium grade with and including all medium grade fittings complete all as specified.
S&F in repair gun metal gate valve with iron wheel head, screwed both ends for iron pipes 25mm bore complete all as specified and directed.
S&F in repair gun metal gate valve with iron wheel head, screwed both ends for iron pipes 40mm bore complete all as specified and directed.
Taking down copper/aluminium point wiring ( light, fan, socket, power ) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surface of walls, floors, etc
Taking down carefully unserviceable Sub main wiring of any size and type, removing material from for taking credit and making good the disturbed surfaces of walls, ceilings etc
Taking down old and unserviceable main incoming MCB DB TPN/ main switch alongwith MCCBs/MCBs and making good the disturbed surface all as directed specified and directed.
M & L for point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories along with one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switch, regulators or bell push and casing capping terminal box for mounting ceiling rose/ holders etc all as specified and directed by Engr-in-Charge for the followings.
One light/fan/exhaust fan point controlled by one,one way switch on independent board
One three pin 5 Amp socket outlet on independent board
One three pin 5 Amp socket outlet on same board
All as per item No 125.00 but FRLSH copper stranded cable of size 4.00 sq mm for 3/6 pin socket outlet 15 amp on one independent board. along with all fitting and accessories complete all as specified and directed by Engr-in-Charge.
All as per item No. 125 but one light point controlled by two 2-way switches.
M & L for sub main wiring with two single core PVC insulated multi stranded FRLSH Copper conductor cable of size 6 sqmm drawn through in and including PVC Conduit of suitable size with all accessories and one single core green colour FRLSH Copper conductor cable of size 6 sqmm as earth wire and connected to earth dolly and making good to disturbed surfaces . NOTE: -Two run of 6 sqmm Copper conductor cable with one run 6 sqmm earth wire and one run of PVC Conduit of suitable size shall be be measured as one unit length.
M & L for sub main wiring with four single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10 sqmm (Nominal area) drawn through in and including PVC conduit suitable size with all fittings and accessories along with one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. NOTE: -Four run of 10 sqmm Copper conductor cable with one run 10 sqmm earth wire and one run of PVC Conduit of suitable size shall be be measured as one unit length.
S&F 5 Amp switch Piano flush type single pole one way all as specified and as directed by Engr-in-Charge.
S&F 5 Amp switch piano type two way all as specified and as directed by Engr-in-Charge.
S & F Angular Lamp holder of PVC/ Polycarbonate type with back plate all as specified and as directed by Engr-in-Charge.
S&F socket flush type 6 amps, 5 pin, 230v all as specified and as directed by Engr-in-Charge.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v
S&F ceiling rose surface Bakelite three terminal complete all as specified and as directed by Engr-in-Charge.
S&F Sheet metal enclosure SPN 08 way (MCB DB) Double door, 240 Volts AC all as specified and as directed by Engr-in-Charge.
S&F Sheet metal enclosure SPN 12 way (MCB DB) Double door, 240 Volts AC all as specified and as directed by Engr-in-Charge.
Supply & fixing sheet metal enclosure double door DBs triple pole and neutral vertical type 415 Volts 4 way (TPN) 16 KA with suitable frame four pole125 Amps in coming MCCBs,bus bars, neutral links, blanking plates IP 43 protection class. Note:-Incoming MCCB & out going MCB shall be measured and paid separately under relevant item of this BOQ.
M & L MCCB 4 pole, 16 KA breaking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps.
S&F MCB TPN 16 to 32 Amps, 415 volt 10 KA ‘’B” curve complete all as specified and directed by Engr-in-Charge.
S&F MCB, SPN (Double Pole) 32 amps, 240 Volts, 10 KA ‘’B” curve all as specified and directed by Engr-in-Charge.
S&F MCB, Single Pole, 5 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’B” curve all as specified and directed by Engr-in-Charge.
S&F repairs LED Light batten 20 watt, 4 feet AC sleek and seamless profiled extruded polycarbonate batten with an efficient diffuser to illuminate work and retail spaces with three core flexible copper conductor cable from ceiling rose complete all as specified and directed by Engr-in-Charge.
S&F in repair LED Light batten 10 watt, 2 feet AC sleek and seamless profiled extruded polycarbonate batten with an efficient diffuser to illuminate work and retail spaces with three core flexible copper conductor cable from ceiling rose complete all as specified and directed by Engr-in-Charge.
S&F LED lamp 12 watt, CDL, B-22 (Pin type), 230V, PF-0.95 (min) all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs ceiling fans complete with blades, down rods, and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge. Note - Old unserviceable ceiling fan deposit to MES store
Supply and fix in repairs exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers incl making of suitable hole in brick / stone wall for fixing of Exhaust Fan and making good the disturbed surface to match with existing surface complete all as directed by Engineer-in-charge. Note - Old unserviceable Exhaust fan deposit to MES store
Material and labour for earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and including 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete including taking out old earthing material complete all as specified and as directed by Engineer -in-Charge
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty )1100 volts grade with stranded aluminium conductor of size 3.5 core 120 sqmm including dismantling/ taking down old unserviceable cable all as directed by Engineer-in-charge Note :Laying of cable shall be in trench/ wall / pole etc as per site requirment
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty )1100 volts grade with stranded aluminium conductor of size 3.5 core 35 sqmm including dismantling/ taking down old unserviceable cable all as directed by Engineer-in-charge. Note :Laying of cable shall be in trench/ wall / pole etc as per site requirment
Excavating in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable, pipe line etc and getting out in soft / loose soil complete all as specified and directed.
Excavating in trenches not exc 1.5m wide and not exc 1.5m in depth for laying UG cable, pipe line etc and getting out in soft disintegrated rock complete all as specified and directed.
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 50 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified Note:-Excavation and earth work shall be measured and paid separately under relevant item of this BOQ
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 120 mm outer dia with all fittings such as clamps. coupler etc laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified . Note:-Excavation and earth work shall be measured and paid separately under relevant item of this BOQ
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI water pipe line through road including making good the disturbed surface by filling mass concrete complete all as specified and directed. Note:-Concrete shall be measured and paid separately under relevant item of this BOQ
Horizon Construction (BID ID -3341850)
Mehta Construction Co. (BID ID -3341639)
UNIQUE ENGINEERS (BID ID -3341469)
vishalconstruction (BID ID -3340431)
United Sales Corporation (BID ID -3336125)
L.K.R.TIWARI CONSTRUCTION (BID ID -3341932)
KHANDELWAL ASSOCIATES (BID ID -3341680)
S.R.M.K Enterprises (BID ID -3341773)
Bidder Name
KHANDELWAL ASSOCIATES
Mehta Construction Co.
United Sales Corporation
UNICON
UNIQUE ENGINEERS
S.R.M.K Enterprises
L.K.R.TIWARI CONSTRUCTION
Horizon Construction
vishalconstruction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .