Tender Value
₹31.1 L
EMD Value
₹62,200
Closing Date
6 Jan 2026, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
43 conditions · 7 needing a document upload
Valid copy of PAN and GSTIN needs to be furnished along with the documents.
Tenderer should fill up the Tender Form (First Sheet) as per 'Annexure-I' of GCC. Incomplete or partial fill up the Tender Form (First Sheet) by the Tenderer will be liable to reject.
For Sole Proprietorship firm a)Affidavit as per 'Annexure'. b)Special power of Attorney as per proforma given in 'Annexure' to be submitted by sole proprietor firm duly notarized.(Not required if tender documents are submitted by proprietor himself) (Mandatory)
For Partnership firm a)Self/Notary attested copies of Partnership deed. b)Special Power of Attorney as per proforma given in 'Annexure' to be submitted by Partnership firm. (Not required if one or more partners are authorized in Parternership deed to sign on behalf of the firm.)
For Limited Company a) Copy of Memorandum & Articles of Association of Company. b)Self /Notary attested copy of resolution passed by Board of Directors authorizing its Director/Employee to deal with tender on behalf of company. c) Attested copy of Notarized Special Power of Attorney including ratification clause duly signed by person authorized by the company.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer is advised to study the uploaded tender document in www.ireps.gov.in portal carefully
The Conditions of tender shall be read in conjunction with General Condition of Contract/2022 subject to modification, additions or supersessions by Special Condition of Contract and Specification if any.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender. Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim whatsoever will be entertained by Railway.
No manual tenders sent by post/Fax/courier or in person shall be accepted.
Electrical works in connection with diversion of roads for closing of LC gates no. NN- 199, NN-201 & NN-205.
RNY-EL-T-20-2025-26~NFR
RNY-EL-T-20-2025-26
Open
Works - General
180 Days
Kamrup, Assam
₹0
₹62,200
6 Jan 2026
12 Dec 2025
23 Dec 2025
25 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 27,85,816.71 | ||
| Supply, carrying, loading & unloading of 5 mtr long with suitable size designer single bracket G I octagonal pole having dia Top 70mm, Bottom 130mm, Thickness 3 mm including base plate of size (200 x12)mm, PCD 200mm, junction box and foundation bolt 4x16 Nos (Length 600mm) etc. and erection with execution of CC foundation work of size 45cmx45cm in ratio 1:2:4 by cement,sand and chips of size 19 mm and down upto full depth & 1ft above the GL as per direction of EIC at site & including 6A SP MCB. | — | — | — | 6,23,508.3 | |
| Supply, installation, testing & commissioning of IP 65 45 watt street light fittings complete including all accessories as per direction of EIC at site . Lumens out put should be of 100 Lumens/watt, LED should be as per LM-80/IS: 16105. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC and driver should be as per IEC: 62384/IS:16104. The LED fittings should be warranted for 5 years. | — | — | — | 2,41,039.35 | |
| Supply, installation, testing & handing over of IP 65 45 watt street light fittings complete including all accessories as per direction of EIC at site. Lumens out put should be of 100 Lumens/watt, LED should be as per LM-80/IS: 16105. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC and driver should be as per IEC: 62384/IS:16104. The LED fittings should be warranted for 5 years. | — | — | — | 1,60,692.9 | |
| Supply of 1100 volt grade, 16 sq mm 4 core XLPE insulated and PVC sheathed aluminium multistrand armoured cable as per IS 7098(Part 1) 1988 with up to date amendments as per direction of EIC at site. | — | — | — | 1,29,729.04 | |
| Supply and laying of GI pipe 50 mm dia thickness not less than 3.6 mm for cable protection with necessary bends, sockets, etc partly through underground and partly through trench as per direction of EIC at site. | — | — | — | 1,11,890 | |
| Laying of above LT XLPE insulated armored aluminum cables with suitable arrangements as per instruction of site engineer. | — | — | — | 5,796.59 | |
| Excavation of cable trench 0.75 mtrs. below the GL with laying of armored cable and refilling the same by supply of 70mm sand and soil after digging the earth. The laying of armoured cable should be done as per direction of Engineer at site. (Cable will be supplied by Railway). | — | — | — | 35,700 | |
| — | — | — | 77,373 | ||
| — | — | — | 8,57,850 | ||
| — | — | — | 3,11,475 | ||
| Supply. Installation, testing and commissioning of outdoor MS cubical type LT feeder pillar box of suitable size and suitable for 415 V, 50 Hz AC supply made out of CRCA sheet not less than 14 SWG. The panel shall be totally enclosed, dust and vermin proof, neoprene gasket of thickness not less than 2 mm shall be used between all adjacent units and beneath all covers so that the joints are effectively dust vermin proof. The busbar chamber shall have three phase & neutral copper busbar of same ratings. The drawing of panel board should be approved by the competent authority before fabrication and commissioning. The panel shall be painted with two coats of primer & two coats of exterior coating by spray painting and shall consists of the following: (i) 63A, 4P, 36kA, Ics=100%Icu, Adjustable over load Setting & Short circuit setting, MCCB - 4 Nos, (ii) 40A, TPN, 'C' Series, MCB - 1 Nos, (iii) Fabrication of Panel board with 14SWG CRCA sheet including CC foundation and 200A TPN Copper busbar), cable alley, C C Foundation etc and all accessories - 1 job. | — | — | — | 2,09,542.53 | |
| — | — | — | 3,22,283.08 | ||
| Supply of Galvanised tubular pole 7.0 mtr long , Type-410 SP-01 including suitable size base plate & cap . The work includes Carrying, loading/unloading and erection of tubular pole 7.0 mtr long by contactor own arrangement by digging the pit to 1/5th of the pole height. Execution of CC foundation work of size 45cmx45m in ratio 1:2:4 by cement,sand and chips of size 19 mm and down upto full depth & 1ft above the GL as per direction of EIC at site. | — | — | — | 1,57,498.4 | |
| Supply, fitting and fixing of G I angle to be fixed on pole with suitable size G I clamp made of 50X5 mm, G I flat with 50X16 mm bolts, nuts and washers etc of size 50x50x6 mm, 1.2 mtr long as per direction of EIC at site. | — | — | — | 5,367.8 | |
| Supply, fitting and fixing of G I angle to be fixed on pole with suitable size G I clamp made of 50X5 mm, G I flat with 50X16 mm bolts, nuts and washers etc of size 50x50x6 mm, 1.3 mtr long as per direction of EIC at site. | — | — | — | 5,697.8 | |
| Supply, fitting and fixing of G I angle to be fixed on pole with suitable size G I clamp made of 50X5 mm, G I flat with 50X16 mm bolts, nuts and washers etc of size 50x50x6 mm ,2.2 mtr long | — | — | — | 4,608 | |
| Supply and stringing of A.C.S.R (Weasel) of size 6/1/2.59 mm as per direction of EIC at site. [Confirming to IS:398:1996 (Reaffirmed 1997)] | — | — | — | 1,12,350 | |
| Supply and stringing of guard wires by 8 SWG GI wire as longitudinal as per direction of EIC at site. | — | — | — | 9,525 | |
| Supply and stringing of guard wires by 10 SWG GI wire as cross lacing at an interval of 1.5 mtr as per direction of EIC at site. | — | — | — | 4,540 | |
| Supply and erection of LT pin insulator of size 82x90 mm (Similar to product No. JS-S 0141 of Jayashree insulator make) complete with all accessories as per direction of E.I.C. at site. | — | — | — | 3,904 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .