Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹20.9 L Quoted ₹21.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹22.8 L+₹99,834 (4.58%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | ₹22.8 L+₹99,834 (4.58%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹24.6 L+₹2.8 L (12.9%)Rejected-AOC | ₹24.6 L+₹2.8 L (12.9%) | L3 | Rejected-AOC Other than lowest bidder. |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
29 Jun 2021, 6:00 pmClosed
GE North Bikaner
GE North Bikaner
CERTAIN REPAIR MAINTENANCE OF STREET LIGHTS HIGH MAST LIGHTS SOLAR LIGHTS AND CONNECTED WORKS UNDER GE NORTH BIKANER AT MIL STATION BIKANER
2021_MES_447544_1
GE (N) BKN-Token/22 /2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE North Bikaner
Class D category b i
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹70,000
Yes
15 Sept 2021
1 Jun 2021
1 Jul 2021
1 Jun 2021
29 Jun 2021
15 Jun 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out complete all as specified. (Taking out old brick from trenches shall be measured separately and deduction for brick shall be made on this account).
Returning, filling in including spreading, leveling, watering and well ramming, in soft/loose soil, in layers not exc. 25 cms. Thick complete all as specified.
Removing surplus soil to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Material and labour for protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the brick is at right angle to the central axis of the cable using old size sub class ‘B’’ brick having compressing strength not less than 75 Kg/ Square cm complete all as specified and as directed.
Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully the defective street light fittings any kind any type from the poles/walls and refixing the same on poles/walls after repair complete all as directed by Engineer in Charge.( Note: A Team of workers for emergency are avlaible inside the camp for 24 Hours) 1. T&P i.e, ladder and vehicle will provided by the contractor.2. The contractor/his rep will collect the complaint from JE every day 9.00 hrs , the same will be rectified before sunset on same day,If the contractor fail to rectify the defect mentioned in the complaint slip on same day, he will be charged Rs 100/per complaint and same will be recovered from the contract amount.
S&F in replacement tube rod for energy efficient street light 24W. Make : Cat Pt Nos T5 24W 6500K (ENERGYLUX) in CG or equvalent to Bajaj/Philips
S&F electronic ballast 2 X 24 Watt suitable for 4x24W street light fitting. Make :Cat Pt Nos EB224T5-A/I in CG or Bajaj/Philips
Supply and fixing in replacement Bipin holder for tube light fittings. Make – Bajaj/Philips/Crompton Greaves
Supply and fixing in replacement outdoor Driver unit 25 watt with surge protection. Make –CG Model SODVES-36-600-25W
Supply and fixing in replacement outdoor Driver unit 40 watt with surge protection. Make –CG Model SODQL1-54-700-40W
Supply and fixing in replacement outdoor Driver unit 45 watt with surge protection. Make –CG Model SODQL-65-700-45W
Supply and fixing in replacement outdoor Driver unit 75 watt with surge protection. Make –CG Model XO75C070V10FNY1B0
Supply and fixing in replacement outdoor Driver unit 150 watt with surge protection. Make –CG Model - X150C070V210FN1B0
Supply and fixing in replacement surge protection devices 5 KV compatible with industrial and outdoor LED fixtures upto rated power of 75 Watt Make CG Model SRPS-5K-440
Supply and fixing in replacement surge protection devices 5 KV compatible with industrial and outdoor LED fixtures with rated power above 75 Watt and upto 150 Watt Make CG Model SRPS-HP-5K-441
S&F inreplacement CFL 36watt 04 PL suitable for street light fitting ‘L’ type.Cat Pt Nos 36W CFL 4P 6500K/2700K/4000K in CG or equvalent to Bajaj/Philips
Supply and fixing in replacement choke/ballast electronic 36/40 watt 230 volt for tube light /CFL fitting. Make – Cat Pt Nos EBN136-A/Sin CG or equvalent to Bajaj / Philips
Supply and fixing in replacement Bipin holder for tube light / CFL fittings. Make – Bajaj/Philips/Crompton
Supply and fixing in replacement ignitor for HPSV/MV street light fitting of any wattage. Make : CG/ Bajaj / Philips
Supply and fixing in replacement porcelain holder pin /thread type suitable for HPMV / HPSV street light fittings suitable for any type and any wattage. 70 W to 125 W.
Ditto all as per item No 21 here-in-before but 150 W to 250 W.
Supply and fixing HPSV /MV lamp capacity 70/80 watt Make : CG/ Bajaj / Philips
Supply and fixing HPSV/MV lamp capacity 150/125 watt Make : CG/ Bajaj / Philips
Supply and fixing HPSV /MV lamp capacity 250 watt Make : CG/ Bajaj / Philips
S & F copper ballast for 70/80 Watt HPSV/MV Make CG/ Bajaj / Philips
All as per item No 26 here-in-before but for 150/125 Watt HPSV/MV. Make : CG/ Bajaj / Philips
All as per item No 26 here-in-before but for 250 Watt HPSV /MH Make : CG/ Bajaj / Philips
Taking down existing high mast head frame for dismantling the unserviceable parts including repair of control panel wiring incl testing ( Note Making suitable arrangements of ladder or crane or scaffolding is the responsibility of contractor .
Taking down and dismantling existing high mast pole of high 12 to 21 mtrs from bottom plate, nuts and bolts complete with the help of suitable T&P required for holding, lifting and dismantaling high mast pole, replacement of unserviceable part ,oiling and greasing of pulleys, gear box, rope and all moving parts including assembling, intallation of high mast pole complete as directed by Engineer in Charge. ( Note. 1. Cost of crane for dismantling high mast pole is deemed to be included in quoted rate. 2. Cost of oiling and greasing of moving parts in deemed to be included in rate quoted.
S&F in replacement of HPSV/MV lamp 400 watt suitable all as specified Tubular Make : CG/ Bajaj / Philips
S & F copper ballast 400 watt MH/SV suitable all as specified cat Pt No HDBI40S/MH or equvalent in Bajaj / Philips in CG
Lamp Holder suilable for 400 watt MH/SV lamp
S & F ignitor 400 watt for MH lamp Make IGN1130MH in CG or equvalent in Bajaj /Phillips
S&F TPN MCB 'C' Curve capacity 40 Amps 10 KA. Make C&S/Havells/L&T/MDS
Taking down by disconncting the existing electrical connections of winch motor for rewinding / repairs including Rewinding the motor of capacity up to 2 HP with best class supper enameled copper wire of existing gauge and size including varnishes and insulating 230 V AC Hz electric supply system . refixing and reconnecting it to the original location for satisfactory functioning of winch on 230 V electric supply system all as specified
Supply and fixing in replacement steel wire rope of 10 mm size and capacity all as specified
Taking down the existing winch gear box of hight mast light 12 to 21 mtrs by disconnecting the winch motor and supply in replacement the winch gear box of appropriate capacity as per sample and make , fixing and connecting the same with winch motor for satisfactory operation of winch on electrical power all as specified
Supply & Fixing of LED based Street light, housing made up of pressure die cast aluminum Alloy with effective thermal management, sturdiness . The fixture should have a minimum system efficacy of more than 100 lumen/Watt and a minimum system lumen output of not less than 1600 lumens and maximum system wattage 16 Watts. The fixture shall have a corelated color temperature of at least 5000K and a CRI of minimum 70 .The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP65 (lamp and gear Compartment and Mechanical Impact Resistance Rating of IK >=05. The fixture driver should have an operating voltage range of 12 V DC, surge protection not less than 4KV.The fixture should comply with the parameters as per IS10322 and for EMI and LM 79 test reports .Including suitable size street light fitting bracket with suitable size clamps,nut bolts and washers as per site requirement complete all as specified as directed by Engineer-in-Charge. Make- Phillips ,Crompton greaves ,Wipro
Supply and Fixing MPPT based charged controller suitable for solar street light 25 Watt, 12 Volts DC with high charging efficiency and integrated high efficiency LED driver Designed as per IEC standards Hybrid version with option of AC backup.Charge controller shall have automatic dusk-dawn circuit based on spv module as sensor for switching on/off the street light without manual intervention
Supply and fixing in replacement Driver unit with surge protection suitable for LED street light ftg of capacity 15 to 25 watt, 12 V DC. Make – Bajaj/Philips/Crompton Greaves
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-0 or Fe-310-0 grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and as directed by Engineer-in-Charge. (Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
Supply and fixing Street light bracket in replacement, made of GI pipe 40mm bore, light grade not less than 1.2 m long bent to shape including fixing with 2 nos suitable size of MS flat iron 40x6 mm clamps, nuts, bolts and washers and making connections all as directed by the Engineer-in-Charge.Make of GI pipe : Jindal/Surya/Prakash
Supply and fixing in replacement for Multistranded single core PVC insulated FRLS copper conductor cable of size 2.5 sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable.
Supply and fixing in replacement for two core PVC insulated weather proof cable with aluminum conductor size 4 sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable.Make Paragone ,finolex , Gloster
Ditto all as per Srl Iem No 45 here in before but size of cable 6 Sqmm 2 core.
Ditto all as per Srl Iem No 45 here in before but size of cable 10 Sqmm 2 core.
Supply and laying in replacement of Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 10 Sqmm 02 core laid in trenches / through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.(ii) Road manually cutting/floor cutting/cutting holes etc in wall required for laying /fixing of cable etc shall be made good as per existing site condition. Nothing extra shall be admissible on this account and quoted rate for this item shall be deemed to include for the same).
Ditto All as per Srl item No 48 here in above but size of cable 16 Sqmm 4 core
Ditto All as per Srl item No 48 here in above but size of cable 16 Sqmm 2 core
Ditto All as per Srl item No 48 here in above but size of cable 25 Sqmm 4 core
Taking out old LT underground cable and laying after removing of defects any type/size laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.
Boring of holes under road, pavement, hard standing by trench manually complete all as specified and as directed by the Engineer-in-Charge.
Tightening GI tube bracket of street lights mounted on poles including realigning to the centre of roads including replacement of necessary nuts, bolts & washers wherever required to be replaced all as directed
Supply and fixing on DB 2 way with SPN MCBs 32 Amps 240 volt, 50 Hz, AC suitable for 'C' curve, 10 KA breaking capacity complete all as specified Make ABB/Siemens/Scheinder
Supply and fixing on ob DB 4 way with TPN MCBs 63 Amps 440 volt, 50 Hz, AC suitable for 'C' curve, 10 KA breaking capacity complete all as specified Make ABB/Siemens/Scheinder
Testing and checking of faulty street light feeder including under ground cable or on the pole on line etc and repair the same after remove the faulty feeder complete testing all as directed by Engineer in Charge Note :- Earth work measured and paid separately.
Taking down Unserviceable time switch , checking / testing Time switch by disconnecting the connection and refixing the same after minor repair/resetting all as directed by Engineer in Charge
Material and Labour for repairing of MS street light junction box, tighting of loose nut, bolts, screws etc including cutting of burnt thimbles/ LT cable, taking out LT cable from Loop and recconecting to bus bar with new thimbles duly crimpped with cable complete all as directed and specified by Eng-in-charge.
Trimming /pruning of the tree branches coming around the street light fittings and making the street light free from touching the tree branches not less the 4 mtr radius
Supply & fixing in replacement of LED decorative post top lantern light fittings for 360 degree indirect light with IP 65 protection, resistant to impact and corrosion, glare free and better uniformity. Make CG Model LPTO-40-CDL or equivalent Make Philips /Bajaj
Supply & fixing in replacement of LED post top lantern light fittings with IP 65 protection, ideal to lit up parks, garden ways etc. Make CG Model LPTH-20-CDL or equivalent Make Philips /Bajaj
Suppy and Fixing LED based street light, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness. The fixture should have a minimum system efficiency of more than 100 lumen/watt and a minimum system lumen output of not less than 7200 lumens and maximum system wattage 72 to 90 Watts. The fixture shall have a correlated colour temperature of al least 5700K and CRI f minimum 70. The fixture shall be designed for a system life of 50,000 hours @ 70% lumen maintenance ingress protection of IP66 (lamp and gear compartment and mechanical inpact resistance raiting of IK>=08. The fixture driver should have an operating voltage range of 140-270 V & potted type for humming free operation, driver should be withstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF>0.95 and THD<10% and have double phase protection. LED light fitting should be suitable for ambient temperature from (-) 10C to (+) 50 C. The fixture should comply with the parameters IEC 60598 and LED should comply to IEC 61000-3-2 ed. 3.2 per harmonics IEC 61347-2-3,2006 in configuration with IEC 61347-1 ed 2.0,2007 for electrical safety LM 79 and for LED LM 80 test report needs to be submitted from the house NABL accreditation laboratory. Make CG/C&S/Bajaj/Havells
Ditto all as per Srl Item No 81 here in before but maximum system wattage 45 Watts. Make CG/C&S/Bajaj/Havells
Ditto all as per Srl Item No 81 here in before but maximum system wattage 25 Watts.Make CG/C&S/Bajaj/Havells
Supply & Fixing of LED based Flood light fitting, housing made up of pressure die cast aluminum Alloy with effective thermal management, sturdiness . The fixture should have a minimum system efficacy of more than 100 lumen/Watt and a minimum system lumen output of not less than 15000 lumens and maximum system wattage 150 Watts. The fixture shall have a corelated color temperature of at least 5000K and a CRI of minimum 70 .The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment and Mechanical Impact Resistance Rating of IK >=05. The fixture driver should be withstand up to 440v for 8hrs, two surge proection not less than 5KV one on driver and one external surge protection, PF >0.95 and THD<20% .The fixture should comply with the parameters as per IS10322 and for EMI and LM 79 test reports .Including suitable size street light fitting bracket with suitable size clamps,nut bolts and washers as per site requirement complete all as specified as directed by Engineer-in-Charge. Make CG/Phillips/Wipro
Preparation of old painted surface and painting of steel Tubular street light pole 12 mtr height double swan neck upto 1.5m above the top of PCC coping with 2 coats of aluminium anti corrosive paints of first quality and painting to pole upto 1.5m height from top of PCC coping with synthetic enamel paint 2 coat in black and white alternate strip including numbering in 8 cm height of number with white paint both paint aluminium/synthetic duly approved by Engineer in Charge complete as directed and specified.
Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch-, 25 kw equally distributed, 63 Amps,3-pole, Model - Swadeep-02 EC 25 Kw3P for automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactor rating 63 Amps 3- pole & 40 Amps 2-pole, MCB SP 63 Amps -03 nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 3- phase load of 25 kw , rating 63 amps 3pole, MCB rating 63 amps SP 03 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1), MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch, 08 kw equally distributed, 63 Amps,1-pole, Model - Swadeep-02 EC 8 Kw1P for automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactor rating 63 Amps 2- pole & 40 Amps 2-pole, MCB SP 63 Amps -02 nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 1- phase load of 08 kw , rating 63 amps 2 pole, MCB rating 63 amps SP 01 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1), MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
Supply and fixing thermplastic cable junction box with IP 66/67 weather proof protection for outdoor installation with knockouts for cable entry and without cable terminals of size 210x310x116 mm suitable for LT UG cable 50 sqmm Make Hensel / Sintex
Supply and fixing in replacement PVC insulated copper tailing cable 5 core 2.5 sqmm suitable for installation on high mast.
BIDAWAT ENTERPRISES
G R POWERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .