| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC 53 TOLLYGUNGE CIRCULAR ROAD KOLKATA 700 053 | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹52.4 L+₹1.9 L (3.84%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹53.2 L+₹2.7 L (5.41%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹54.1 L+₹3.7 L (7.25%)Rejected-Finance 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹55.3 L+₹4.8 L (9.57%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Feb 2022, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/REPLACEMENT AND MAINTENANCE OF SEWAGE TREATMENT AND ASSOCIATED INSTALLATIONS INCLUDING REPAIR TO JOINERY, FLOORING ETC AND REPAIR/MAINTENANCE OF WATER SUPPLY INSTALLATIONS SYSTEM (B/R AND INTERNAL ELECTRIFICATION WORKS) AT INSIDE FORT WILLI
2022_MES_503097_1
8820/E8
Open Tender
Civil Works
Item Rate
240 days
GE(FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE(FW) Kolkata
₹90,000
30 Mar 2022
22 Jan 2022
15 Feb 2022
22 Jan 2022
14 Feb 2022
4 Feb 2022
Amount
SCHEDULE 'A' PART-I (BUILDING WORKS) Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors/vertical surfaces, etc laid, bedded and pointed in any mortar, etc complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as directed.
Taking down shutters of any description n.exc 1.00 Sqm each all as directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each all as directed.
Hacking out old broken glass (any thickness and size or quality) from wooden frames glazed with putty or fixed with beads complete all as specified and directed.
. - ditto - all asper item No. 12 here-in-before, but from metal frame.
Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for brick work using old size fly-ash bricks straight or curved on plan exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
-ditto- but using old serviceable bricks obtained from demolition
M&L Brick Work with fly-ash Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation or for shafts, wells cesspits, manholes etc., not exceeding 10 sqm on plan and getting out in soft/loose soils, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point in soil complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type 'C-2' (using 40mm graded crushed stone aggregate) as in sub base of concrete finished even and fair cement complete all as directed..
M&L for 75mm thick PCC (1:3:6) type 'C-2' (using 40mm graded crushed stone aggregate) as in floor, plinth protection etc, surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L 5 mm thick rendering in cement mortar (1:3) on ceilings, finished even and smooth without using extra cement all as specified and as directed.
S&F for 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
M&L 18-20 mm thick coloured granite tiles, machine cut as in steps, jambs, pillars, window cills, cooking platforms and on floor over and including 15mm thick backing layer in cement mortar (1:6), set and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite tile including rubbing and polishing complete all as specified and as directed.
M&L Preparing new Surfaces of Walls and applying Two Coats of Exterior Emulsion Paint (as per Manufacturer’s instructions) over a coat of primer suitable for external surfaces complete all as specified and directed. (Make of Paint: Asian Paint (Apex Ultima) / ICI Dulux (Weather Shield Max) / Berger (Weather Coat All Guard) / Shalimar Paints (Xtra Maximum) / Nerolac (Excel Total)/ Jotun (Jotashield Water Xtreme)
M&L Preparing old decorated surfaces and applying one coat of Exterior Emulsion Paint (as per Manufacturer’s instructions) over a coat of primer suitable for external surfaces complete all as specified and directed. (Make of Paint: Asian Paint (Apex Ultima) / ICI Dulux (Weather Shield Max) / Berger (Weather Coat All Guard) / Shalimar Paints (Xtra Maximum) / Nerolac (Excel Total)/ Jotun (Jotashield Water Xtreme)
S&F stainless steel wire cloth, 0.65mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
. - ditto - all as per item No. 31 here-in-before, but fixed in repair.
S&F 4mm thick ordinary quality plain sheet glass glass and glazing in square n.exc. 0.5 Sqm in each pane complete all as specified and directed.
-ditto- but in metal frames with oil putty
S&F 4.8mm thick ordinary quality frosted sheet glass glass and glazing in square n.exc. 0.5 Sqm in each pane complete all as specified and directed.
-ditto- but frosted glass in metal frames with oil putty
S&F 30mm thick Factory made 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L mild steel bands and straps support or stays holdfast and similar articles conforming complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type 'B-1' (using 20mm graded crushed stone aggregate) as in floor finished fair and even without using extra cement complete all as a specified and as directed
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
- ditto - all asper item No. 41 here-in-before, but 200mm long all as directed complete all as specified and directed.
S&F Factory made solid PVC door frame (chowkhat) of size 50mmx47mm made out of 5mm plain colour wood grain PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube, S&F in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
S&F Factory Made Solid Panel PVC Door Shutter 30mm thick, consisting of frame made out of Mild Steel Tube of 19 Gauge thickness and size of 19mm x 19mm for Stiles and 15mm x 15mm for Top & Bottom Rails. Mild Steel Frame shall have a coat of Steel Primer of Approved Make and Manufacturer. Mild Steel Frame shall be covered with 5.0mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming Stiles and 5.0mm thick, 75mm wide PVC Sheets For Top Rail, Lock Rail & Bottom Rail on either side, and 10mm (5.0mm x 2) thick, 20mm wide Cross PVC Sheet as gap insert for Top Rail, Lock Rail & Bottom Rail. Panelling of 5.0mm thick PVC Sheet Beading on either side and joined together with Solvent Cement Adhesive, etc. An additional 5.0mm thick PVC Strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC Solvent Adhesive, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, complete all as specified and as directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as specified and directed.
- ditto - all as per item No. 45 here-in-before, but fixed in repair.
Supply & fixing 100 mm stainless steel butt hinges (medium weight) complete all as specified and directed.
- ditto - all as per item No. 47 here-in-before, but 75mm.
Supply and fixing in repairs 150mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
M&L for pre-polished Chequred cement concrete tiles (coloured) of size 30cmx30cmx22-25mm thick , set, jointed and pointed in neat cement slurry in floor and pointed with white/coloured cement & pigment to match the surface laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed .
M&L for preparing new surface of wood or wood based material of any description and in any position not otherwise described exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as directed.
M&L for preparing old decorated surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as directed.
M&L for preparing new steel surfaces, of any description and in any position not otherwise described exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, treating ends of posts, back of chowkhats etc, with tar or coal tar black paint, area tarred exc 0.1 sqm but n. exc 0.5 sqm each complete all as specified and directed.
-ditto- but treating small articles such as holdfasts, ends of posts, back of chowkhats, etc, area n exc 0.1 sqm each
M&L for complete removel of existing treatment on walls and applying two coat of cement based paint over a coat of alkali resistant primer, complete all as specified and directed .
M&L for preparation of old decorated surfaces of wall and applying one coats of oil bound distemper, complete all as specified and as directed .
M&L for preparation of old decorated surfaces of ceiling and applying one coat of oil bound distemper complete all as specified and as directed.
M&L preparing old steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L applying one coat of cement base paint on walls, cornices incl preparation of old plastered or unplastered surfaces of wall complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of any description and applying one coat of acrylic distemper, white or tinted on walls cornices etc all as specified and directed.
M&L for applying one coat of white wash to old decorated surfaces of ceiling including preparation of surfaces complete all as specified and as directed.
M&L for applying one coat of white wash to old decorated surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L Glazed Ceramic colored tiles of size 300x450x7mm thick in vertical surfaces, set and jointed in neat cement slurry, fixed over and including 10 mm thick screed bed in cement mortar 1:4 as backing layer and pointed in white or colured cement to match complete all as specified and as directed.
M&L Non Skid joint free coloured tiles 7-8mm thick area of each tiles exc 0.11 Sqm but n. exc 0.16 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bedding in cement mortar 1:6 complete all as a specified and as directed
S&F in position, at or near ground level, factory made precast cement concrete kerb stone blocks, in M-25 grade cement concrete, fixed to the required line, level and curvature, jointed in cement mortar 1:3, including making joints with or without grooves (thickness of joints, except at sharp curves shall not be more than 5 mm) including making drainage opening wherever required complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D2 using 40 mm graded aggregates in sub base of floor, path, hardstanding etc complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi tred/stopped ends etc complete all as specified and directed.
S&F in repair cast iron work Gd FG-150 unmachined as in brackets, gratings, gully traps, manhole covers etc in articles not exceeding 5 Kg each complete all as specified and directed.
S&F in repair cast iron work Gd FG-150 unmachined as in brackets, gratings, gully traps, manhole covers etc in articles exceeding 5 Kg each complete all as specified and directed.
S&F in repair precast cement concrete louvres and jallies, 35mm thick (measured solid) 1:2:4 type B0 (using 12.5 mm graded stone aggregates) & set in cement mortar 1:4 including all mouldings but excluding frame complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over 15mm thick screed bed in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
M&L for laying and fixing Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick cement screed in cement mortar 1:3 and jointed etc complete all as specified and directed.
M&L for Factory made solid PVC moulded door shutter, 28 to 30 m thick(stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core complete all as specified and directed.
S&F Factory made solid PVC door frame (chowkhat) of size 100 mm x 45mm made out of 5mm plain colour PVC sheet, frame reinforced with MS square tube of size 40mm x 20mm of 19 guage throughout the frame, fixed in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
S&F 0.56 mm thick plain aluminium sheeting alloy 31000 H4, fixed on backside of wooden door/expansion joint of roof and wall complete all as specified and directed.
Taking out precast interlocking paver block, any size, and keeping aside for re-use or removal from site complete all as specified and directed.
Supply and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. (NOTE: Cost of sand cushioning is deemed to be included in the quoted rates)
M & L for heavy duty ceramic floor tiles of size 300 x 300 x10mm thick in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. (MAKE : JOHNSON, Model : Endura or equivalent item in other makes listed in the tender)
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed.
-ditto- but using serviceable old steel sections obtained from demolition including necessary cutting, welding etc complete all as specified and directed.
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for Expanded metal, cut to length, bent to shape required and tying with and including anealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight n exc 4 Kg per sqm complete.
M & L for 20 mm thick plastering in two layers, 10 mm each in cement mortar 1:4 with water proofing compound (as per manufacturer's specifications) on brick/stone walls or concrete surfaces finished even and fair ( upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
M&L 10 mm thick rendering in cement mortar (1:3) to brick or concrete wall surfaces, finished even and smooth without using extra cement, all as specified and as directed.
M&L 5mm thick cement plaster on concrete surfaces without using extra cement finishing fair and even in cement mortar 1:3 including necessary scaffolding complete all as a specified and as directed
M&L for Mild steel plain black sheet in wall cladding steel gates and similar work, cut to size, holes punched including round headed screws etc of sheet thickness 1.00 mm complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
-ditto- but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
M&L for Mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges, wheels or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming toFe-410-W(Gde-E-250)quality-B complete all as specified and directed.
S&F in repair mild steel Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Servicing, overhauling, greasing, easing collapsible gate, of any area complete all as specified and directed.
Servicing, overhauling, greasing, easing rolling shutter, of any area complete all as specified and directed.
S&F in repair 110mm OD PVC (SWR) pipes, single socketed, conforming to IS:13592-1992, type 'A', in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius for 110 mm OD PVC pipes complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal for 110 mm OD PVC pipes complete all as specified and directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L TMT Bars 6-8 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M & L for Providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) Set in position in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary forms, moulds, etc complete all as specified and as directed. (NOTE: MS reinforcement shall be measured and paid seperately)
Taking up/down plants or vegetation growth from wall up to roof level (from ground level upto fourth floor) by means of cutting hole into brick wall and making good the surface of dismantled portion (not exc 150 sq cm superficial area and not exc one brick depth) using brick bats /aggregate and plastering in cement mortar (1:3) or cement concrete (1:2:4) type B1 (using 20 mm graded aggregates) to disturbed portion and applying two coats of cement base paint/exterior emulsion paint over a coat of primer to match the existing surfaces complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors shutters, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips rubber neoprene packing, handles 2 Nos in each door, hinges, Mortice lock vertical type size 100 mm 4 levers of brass in each door, anodised aluminium snap beading screws etc as per manufactures instruction complete all as specified. (NOTE: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle, mortise lock etc as described in item. Sheet glass shall be measured seperately)
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, anodised aluminum fittings such as suitable 150 mm long peg stays (01 No), hinges type B-21 100 mm long (02 Nos), suitable handle-01 No each shutter etc as per manufactures instruction complete all as specified and directed. (NOTE: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle etc as described in item. Sheet glass shall be measured seperately)
S&F in repair powder coated aluminium wndow grill of size 100 mm X 100 mm having section width 6 mm and 3 mm thickness, fixed on aluminium section weighing not less than 0.55 kg/sqm including necessary jointing, fitting etc all as per manufacturer's instruction complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20 mm graded aggregates) in coping/encasing around pole incl necessary form work, surfaces finished evan and smooth without using extra cement complete all as specified and directed.
Taking up or down steel water tubing 15 mm bore incl connection , cleaning etc complete all as specified and directed.
-ditto all as per item No 108 here-in-before but 20 mm bore
-ditto all as per item No 108 here-in-before but 25 mm bore
-ditto all as per item No 108 here-in-before but 40 mm bore
S&F tubes 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
-ditto all as per item No 112 here-in-before but 20 mm bore
-ditto all as per item No 112 here-in-before but 25 mm bore
-ditto all as per item No 112 here-in-before but 40 mm bore
Taking up/down unserviceable/rusted valve pit cover frame / support or platform etc and supply, fabrication and fixing of framed brackets, made of mild steel flat / angle iron (of required size), cut to shape and size, as in valve pit cover frame / support or platform including necessary bending / welding etc as required and applying two coats of black bituminous paint over a coat of red oxide zinc chrome primer complete all as directed by the Engr-in-Charge.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 50 mm average thickness (Any storey/ height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed by Engr-in-Charge.
Deduct / Add for below / over 5mm or part thereof thickness for item No 107 above (Any storey/ height of building/ structure)
M&L for applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by wire brush & sand/emery paper (after 24 hours of application of rust remover) and cleaning the area thoroughly by water with the help of pressure jet and allowing it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and as directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product other makes specified in tender) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
M&L for introducing new mild steel TMT reinforcement bars upto 12 mm dia for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Quoted rate is deemed to be inclusive of the cost of reinforcement bars)
M&L for preparation of old existing corroded and new introduced reinforcement surface (at any storey/ height of building/ structure) by brush and application of two component epoxy based zinc rich primer, of minimum specific gravity 1.75, adhesive bond strength with steel as 1.50N/mm2, as a protective coating to steel reinforcement bars in concrete with total zinc content in dry film >90% by volume and DFT per coat >50 microns complete all as specified and directed. (Make- Nitozinc primer of FOSROC or equivalent product in other makes specified in tender) (NOTE: Surface area of steel reinforcement shall be measured for payment)
M&L for applying shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar, as per manufacturers instructions to get a compressive strength of 35 MPA after 28 days, finishing surfaces even and smooth complete all as specified and directed. (Make- Rendroc SP 40 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for applying a coat of epoxy bonding agent on existing concrete surfaces, with mixed density 1.48 Kg/litreand adhjesive bond strength>2.50 MPs, mixed and applied as per manufacturer's specifications complete all as specified and directed. (Make- Nitobond EP of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days, 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 50mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and directed.. (Make of micro concrete:- Renderoc RG of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction (for any storey/ height of building/ structure) complete all as specified and directed. (Make:- Concure LP90 of FOSROC or equivalent product in other makes specified in tender)
M&L for applying two component structural grade polymer modified reinstatement mortar of compressive strength, flexural strength shall not be less than 45 MPa at 28 days, 7 MPa at 28 days respectively (maximum coverage area 1.30 sqm per 25 kg pack @ 10mm thickness) over a coat of epoxy bonding agent on existing surface for strengthening of beams, columns and other structural element of average thickness 25 mm and mortar shall be applied in layer not exc 6 mm thick in layers and including surface preparation as per manufacturer's instructions complete all as specified and directed (any storey/height of building/structure). (Make- Rendroc S2 of FOSROC or equivalent product in other makes specified in tender)
Disconnecting existing water storage Tank of capacity exceeding 1000 litres but not exceeding 2000 liters for cleaning of water tank, removing of mud, sludge etc and flushing with chlorine water including supply and fixing of any damaged accessories for water Tank and re-connecting and refixing all connections complete all as specified and directed.
Disconnecting exiting water storage Tank of capacity exceeding 500 litres but not exceeding 1000 liters for cleaning of water tank, removing of mud, sludge etc and flushing with chlorine water including supply and fixing of any damaged accessories for water Tank and re-connecting and refixing all connections complete all as specified and directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for brushing cement slurry @ 2.75 Kg/sqm over cleaned roof surface prior to application of concrete complete all as specified and directed.
M&L for Providing Cement Concrete, Type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, finished even and fair complete all as directed by Engineer - in - charge .
M&L for cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregates) as required complete all as specified and directed.
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane.
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 137 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 137 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 137 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F electronic type stepped speed regulator, 100 watts, AC 230 Volts for ceiling fan, complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through and incl PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 148 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 2.5.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site complete all as specified and directed.
S&F Double Door, Sheet Metal Enclosure for DBs (normal range), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : C&S, Cat No: CSDBSPNPDD08 / BCH, Cat No: BCHSPNDD08W / HPL, Cat No: MDBDD08 / HAVELLS, Cat No: DHDPSHODRW08 / INDO ASIAN, Cat No: 811807)
S&F SPN DB, IP 43 protection, double door (normal range), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : C&S, Cat No; CSDBSPNPDD04 / BCH, Cat No: BCHSPNDD04W / HPL, Cat No: MDBDD04 / HAVELLS, Cat No: DHDPSHODRW04 / INDO ASIAN, Cat No: 811824)
NOTE FOR ITEM NO. 151 to 152 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured & paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repair PVC insulated and PVC sheathed multicore cable unarmoured with aluminium conductor of size 6 sqmm 2 core suitable upto 1100 volts grade conforming to IS:694, running through and including PVC conduit of size 25 mm dia and connected to DP enclosure complete all as specified and directed.
SCHEDULE 'A' PART-III (EXTERNAL WATER SUPPLY WORKS) S&F in repair Gun metal gate valve, 80 mm bore, as per IS : 778-84 Class-1 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions complete as all specified and as directed.
-ditto- but 50 mm bore
-diito- but 40 mm bore
-diito- 25 mm bore
-diito- 20 mm bore
S&F in repairs MCB, 'C' series, TPN, 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repairs MCB, 'C' series, TPN, 40 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repairs MCCB 4 pole, 415 volts, adjustable type, 250 Amps with breaking capacity 25 KA, front operated with extension rod fixing on existing LT panel board complete all as specified and directed. (Make- L&T, Cat No: CM90642OOPO / C&S, Cat No: CSE2M250ATM4P250 / LEGRAND, Cat No: 4202 19 / HAGER, Cat No: HHT251DR)
M&L complete removal of old paint on panel boards of any description, over 10 cm width or girth, cleaning and prepartion and applying through spray painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for lifting of submersible pump set of capacity 7.5/10 HP from sewage sump for cleaning of pump impeller including all necessary arrangement for lifting of pump set and installing the pump in position after cleaning complete all as specified and directed.
M&L for lifting of submersible pump set of capacity 3/3/5 HP from sewage sump for cleaning of pump impeller including all necessary arrangement for lifting of pump set and installing the pump in position after cleaning complete all as specified and directed.
S&F in repair submersible pump DOL starter in sheet enclosure type MU-G6, 415 volts, 3 ph, 6 HP and relay rangig from 9 Amp to 14 Amp complete with single phase preventer complete all as specified and directed. (Make- L&T Cat No : SS97756 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / HPL)
S&F in repair FASD Submersible pump starter in sheet enclosure type MU-G15, 415 volts, 3 ph, 15 HP and relay rangig from 13 Amp to 22 Amp complete with single phase preventer complete all as specified and directed. (Make- L&T Cat No : CS94091SODO or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / HPL)
S&F in repair DOL motor starter, in sheet enclosure with suitable contactor & overload relay, 415 volts, 3 ph, 2 HP and relay ranging 2.5-4 Amp complete with complete all as specified and directed. Make - C&S, Cat No: BE1-D1735N308 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair DOL motor starter, in sheet enclosure with suitable contactor & overload relay, 415 volts, 3 ph, 3 HP and relay ranging 4.0-6.0 Amp complete with complete all as specified and directed. Make - C&S, Cat No: BE1-D1735N310 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair DOL motor starter, in sheet enclosure with suitable contactor & overload relay, 415 volts, 3 ph, 5 HP and relay ranging 5.5-8.0 Amp complete with complete all as specified and directed. Make - C&S, Cat No: BE1-D1735N312 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair DOL motor starter, in sheet enclosure with suitable contactor & overload relay, 415 volts, 3 ph, 7.5 HP and relay ranging 9-14 Amp complete with complete all as specified and directed. Make - C&S, Cat No: BE1-D1735N316X or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F Cast iron impeller, suitable for 5 HP capacity monoblock pump as in repair, complete all as directed by the Engineer-in-Charge. Make MBH,Model No- MBHN-10.
S&F in repair mild steel chain of length 8 metre, made out of 10mm rod, 50 mm dia rings, weight not less than 16 kg each and fixing in position complete all as specified and directed.
Supply & Fixing analog Ammeter 0-50 Amps 3 phase, AM50A, 415 volts, AC supply of size 96 mm x 96 mm, with current transformer of suitable ratio incl taking down existing meter & CT ccomplete all as specified and directed by Engr-in-charge. (Make - C&S Ref No AM50A or equivalent item in other approved makes mentioned in tender)
Supply & Fix analog Voltmeter 0-500 Volts 3 phase, VM 500 415 volts, AC supply of size 96 mm x 96 mm, incl taking down existing meter complete all as specified and directed by Engr-in-charge. Make - C&S Ref No VM5000 or equivalent item in other approved makes mentioned in tender)
Supply and fix LED Indicating lamp RYB (Red, Yellow & blue set of three),415V, as in repairs, complete all as specified and as directed by Engr-in-charge Make C&S or equivalent.
S&F in repair Electronic timer of type ST-100, suitable for 9- 30 seconds, 240V / 415 V complete all as specified and directed. (Make : L&T, Cat No SE 92002 / 92006 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair current transformer of ratio 30/5 complete all as specified and as directed
S&F in repair Rotary switch (ON-OFF), suitable for 415V 63 Amps, 3 way, 4 pole, as in repairs, complete all as specified and as directed
S&F in repair three pole power contractor of type MNX 40 suitable for 415 volts 63 amps, 3 way, 4 pole complete all as specified and as directed. (Make- L&T Cat No : CS 94190 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / HPL)
S&F in repair bi-metal overload relays ranging from 14 Amp to 23 Amp complete all as specified and directed by Engr -in -charge. (Make : L&T, Cat No : CS 9421100 DO or equivalent item in other approved makes mentioned in tender)
S&F in repair single phase preventer auto reset relay, 40 volts unbalance complete all as specified and directed by Engr-In-Charge. (Make: Minilec Cat No VSP-3 or equivalent item in other approved makes mentioned in tender)
Disconnecting of electric connection, taking out horizontal centrifugal type nonclogging self priming pumps of capacity 1 HP from sewage treatment plant transporting to workshop rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the motor, transporting upto site, re-installation and testing of the assembly as directed including replacement of DE/NDE bearings - 02 Nos complete as directed by the Engineer-in-Charge. (Make of pump: Kirloskar)
-ditto- but for 5 HP pump
M&L Cleaning of 0.240 MLD RCC construction equilization tank of size 5.0m x 4.0m x 2.0m (Inner dimension) along with fine bar screen chamber, grit chamber and connected system by blocking the inlet / outlet flow from manholes, lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed and depositing in collection pit duly spreading of bleaching powder in adequate quantity over sludge and adjoining area including necessary earthwork for excavation of pit and returning filling and opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 0.240 MLD RCC construction clarified water tank of 8.5m x 4.0m x 2.0m (inner dimension) and lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) and removing the same at a distance n.exc 50m from site where directed, and depositing in collection pit duly spreading of bleaching powder in adequate quantity over sludge and adjoining area including necessary earthwork for excavation of pit and returning filling and opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 0.240 MLD RCC contruction FMR (fludised media reactor) with tube setter / lamela setter tank ( MBBR and tertiary system) of size 10.5m x 3.2m x 3.0m (Inner dimention) and lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank), and removing the same at a distance n.exc 50m from site where directed and depositing in collection pit duly spreading of bleaching powder in adequate quantity over sludge and adjoining area including necessary earthwork for excavation of pit and returning filling and opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 0.240 MLD RCC construction sludge Holding tank of size 3.0m x 2.0m x1.8m (Inner diamention) and lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed and depositing in collection pit duly spreading of bleaching powder in adequate quantity over sludge and adjoining area including necessary earthwork for excavation of pit and returning filling and opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
Disconnecting of electric connection, taking out centrifugal motor of 2 HP from base, transporting to workshop for rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the motor, varnishing, transporting upto site, re-installation at site incl overhaulding, greasing of pump, testing of the assembly as directed including replacement of DE/NDE bearings - 02 Nos complete as directed by the Engineer-in-Charge. ( Make of pump: Kirloskar)
-ditto- but for 3 HP motor
-ditto- but for 5 HP motor
-ditto- but for 7.5 HP motor
Supply and laying in repair electrical insulating mat of size 2.0 m X 1.0 m, 2.5 mm thick, made out of dielectric elastomer , natural or synthetic in nature, having elastic properties, suitable for working voltage 11 KV, proof voltage 22KV, breakdown voltage 45 KV, fire retardant, having self-extinguishing propery within 5 seconds of lighting, high elongation & tensile strength, no tear or breakage due to trolley movement & foot traffic, resstant to acids and alkalies, solvents or transformer oil, pastable type, water and moisture proof complete all as specified and directed.
M&L Complete removal of old paint on surfaces of motor pump set of various capacity and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (using spray gun) including preparation of surfaces for any description/type with marking of SM/MES No of pump sets complete all as specified and as directed by the Engr-in-Charge for the following capacities :-
Motor pump set of 2 HP capacity
Motor pump set of 3 HP capacity
Motor pump set of 5 HP capacity
Motor pump set of 7.5 HP capacity
Motor pump set of 10 HP capacity
S&F in repair Pump shaft SS type of sewage submersible pump sets (Vertical/ Horizental type) of various capacities complete all as specified and as directed for the following :- (Make - MBH)
Pump shaft SS type of pump set of 2 HP capacity
Pump shaft SS type of pump set of 3 HP capacity
Pump shaft SS type of pump set of 5 HP capacity
Pump shaft SS type of pump set of 7.5 HP capacity
Pump shaft SS type of pump set of 10 HP capacity
S&F in repair mechanical lower and upper seals of sewage submersible pump sets of various capacities, non clog type and filling new cooling oil complete all as specified and as directed for the following:- (Make: MBH)
Mechanical lower and upper seal for pump set of 2/3 HP capacity
Mechanical lower and upper seal for pump set of 5 HP capacity
Mechanical lower and upper seal for pump set of 7.5 HP capacity
Mechanical lower and upper seal for pump set of 10 HP capacity
S&F Bearing including lubrication of all moving parts for submersible type sewage pump sets non clogging type of capacity 7.5 HP, as in repairs, incl taking down of existing bearing complete all as specified and as directed. (Make of pump : Greatind, Model No- GISE-10)
S&F Bearing including lubrication of all moving parts for submersible type sewage pump sets non clogging type of capacity 3 HP, as in repairs, incl taking down of existing bearing complete all as specified and as directed. (Make of pump : Kirloskar)
Testing of inlet and outlet sewage samples for all parameters as per Enivornmental Protection Act for effluent discharge into inlet surface water form Govt regconised or approved institute/test labs and submit the test report, complete all as directed by Engr-in- Charge. (Note : Testing of one sample each for inlet and outlet shall be considered as one job. Testing shall be carried out once in a month at regular interval)
S&F in repair Add on auxilary contract block 2NO + 2NC incl necessary elect connections including taking down existing contact block complete all as specified and as directed. (Make : L&T, Cat No CS94114 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Add on auxilary contract block 1NO + 1NC incl necessary elect connections incl taking down existing block complete all as specified and as directed. (Make : L & T Cat No CS94118 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Three pole power contactor of type MNX 25 suitable for 415 Volts, incl taking down complete all as specified and as directed. (Make : L&T, Cat No CS 94110 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Three pole power contactor of type MNX 12 suitable for 415 Volts,in cl taking down complete all as specified and as directed. (Make : L&T, Cat No CS 94108 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Three pole power contactor of type ML-1.5 suitable for 415 Volts,in cl taking down complete all as specified and as directed. (Make : L&T, Cat No SS 991851 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in reair Three pole power contactor of type ML-2 suitable for 415 Volts, 40 Amps incl taking down complete all as specified and as directed. (Make : L&T, Cat No SS 90701 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Thermal Timer 415 Volt Gt 200 AC thermal type with coil incl taking down existing timer complete all as specified and as directed. (Make : L&T Cat No- SS91270 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL).
Taking up vertical non-clogging type sub-mersible pump set of capacity 10 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking up vertical non-clogging type sub-mersible pump set of capacity 7.5 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking up vertical non-clogging type sub-mersible pump set of capacity 5.0 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking up vertical non-clogging type sub-mersible pump set of capacity 3.0 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking out vertical non-clogging type sub-mersible pump set of capacity 10 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation includung and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos (Make of sewage pump : KSB, Model No-BPHA 384/3D)
Taking out vertical non-clogging type sub-mersible pump set of capacity 7.5 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation includung and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos (Make of sewage pump : KSB, Model No-BPHA 384/3D)
Taking up electric driven vertical non clogging type submersible pump set of capacity 5.0 HP from sewage sump with connected pipes, transporting to workshop for repair including serving of pump set and motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including gressing, oiling reassembling, transporting upto site, re-installaion and testing of the pump aset including replacement of following worn-out parts as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos (Make of sewage pump : Kirloskar)
Taking up electric driven vertical non clogging type submersible pump set of capacity 3.0 HP from sewage sump with connected pipes, transporting to workshop for repair including serving of pump set and motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including gressing, oiling reassembling, transporting upto site, re-installaion and testing of the pump aset including replacement of following worn-out parts as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos (Make of sewage pump : Kirloskar)
Supply only lead confirming to IS 782 complete all as specified and as directed.
Taking up /down CI/DI water mains and connections/fittings of any type from trenches /walls/floors/(or any other location) for replacement /reuse in old/new location/diversion by burning out /removing of lead joints/tyton joints/rubber gasket joint complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Note for Item No 218 : Necessary earthwork, if any shall be measured and paid separately under relevant item.
Supply, laying and testing of cast iron pipes with spigot and socket ends centrifugally cast of Class 'A' in any length, laid in trenches complete all as specified and directed for following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
M&L Jointing of flanged pipes and fittings with rubber or fibre board gasket , bolts, nuts, washer as in repair complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Burning out lead joints in position of cast iron pipes, fittings and re-making using old retrived lead complete all as specified and directed for following size of pipes :-
80mm bore
100mm bore
150mm bore
200mm bore
Note for Item No 221.01 to 221.04: In case, inadequate lead is retrieved from burning out, for remaking joints, additional lead required shall be measured and paid separately as "Supply only".
S&F CI butterfly valve, conforming to BS-5155, Gear operated with necessary rubber gaskets, nuts and bolts and washers of suitable size as in repair complete all as specified and directed for the following size of pipes :-
80mm bore
100mm bore
150mm bore
S&F Cast Iron Sluice valve of Class PN-1.6 long body type, heavy duty, ISI marked (IS 1538) flanged end with iron wheel and brass spindle including rubber gasket joints, nuts, bolts etc as in repair complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair Cast Iron non-return valve, heavy duty, ISI marked (IS 5312) PN-1.6, flanged end including rubber gasket joints, nuts, bolts etc complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
S&F CI/DI bend upto 150 mm bore (any type, radius and angle) taper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
S&F CI/DI bend upto 200 to 300mm bore (any type, radius and angle) taper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
S&F in repair CI foot valve 80 mm dia, threaded type complete all as specified and directed.
Supply and fixed Mild steel plates chequared Fe-410-W (Gde-E-250) quality-B, 6mm thick as per site requirement as in repairs, complete all as specified and as directed by Engr-in-charge.
M&L Mild Steel Screw Bolts (machine made) 11mm to 15mm diameter of neck and length of bolt exc 5 Cm and not exc. 10 Cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
M&L Stripping off existing starter panel and replacing of single phase preventer maching with motor of type VSP-3 and re-assembling of the panel including rectification of fault and safety device, adjustment of time etc complete all as directed by the Engr-in-charge. (Make- Minilec Cat No- 7W 15473 or equivalent item in other approved makes mentioned in tender)
S&F in replacement of PVC insulated cable with Electrolytic Grade Annealed copper conductor 2.5 Sqmm, 3 core and multi-stranded flat for submersible pump motor, 1100 volt grade as per confirming to IS:694:1990 flat cable complete all as specified and as directed.
-ditto- but PVC insulated flat cable with Electrolytic Grade Annealed copper conductor of size 4.0 Sqmm, 3 core and multi-stranded flat for submersible pump motor
-ditto- but PVC insulated flat cable with Electrolytic Grade Annealed copper conductor of size 6.0 Sqmm, 3 core and multi-stranded flat for submersible pump motor
S&F in repairs, SS impeller suitable for horizontal centrifugal sewage pump sets non clogging type, of capacity 3 HP, complete all as specified and directed. (Make of pump - Greatind)
S&F in repairs, SS impeller suitable for horizontal centrifugal sewage pump sets non clogging type, of capacity 7.5 HP, complete all as specified and directed. (Make of pump - Greatind)
S&F in repairs SS impeller as existing design of the vertical / Horizontal submersible sewage pump sets of capacity 3HP non clog type complete all as specified and as directed by Engr- in- charge.
S&F in repairs SS impeller as existing design of the vertical / Horizontal submersible sewage pump sets of capacity 5HP non clog type complete all as specified and as directed by Engr- in- charge.
S&F in repair SS impeller as existing design of the vertical / Horizontal submersible sewage pump sets of capacity 7.5HP non clog type complete all as specified and as directed by Engr- in- charge.
S&F in repair SS impeller as existing design of the vertical / Horizontal submersible sewage pump sets of capacity 10HP non clog type complete all as specified and as directed by Engr- in- charge.
S&F in repair FRLS-H PVC insulated (unsheathed) single core multi strand cable with electrolytic grade annealed copper conductor suitable up to 1100 volts grade confirming to IS : 694, complete all as specified and as directed for the following sizes:-.
Single core 6.0 sqmm wire
Single core 4.0 sqmm wire
Single core 2.5 sqmm wire
M&L for taking out air blower of Kirloskar make, capacity 7.5 HP from base for transporting to workshop for dismantling, overhauling and repairing of the air blower including re-assembling, greasing, transporting upto site, re-installation and testing of the assembly complete all as specified and directed by Engr-in-Charge including replacement of the following unserviceable parts :- (a) DE/NDE bearing - 02 Nos (b) Gear Oil - 5 litres (c) SS Shaft of suitable size - 01 No (d) Oil Seal - 02 Nos
S&F in repair wet grinder belt A50 for Air Blower of capacity 7.5 HP complete all as specified and directed. (Make: Ecodrive Plus / Fenner or any other reputed make as approved by GE)
S&F in repairs GI "Medium grade" column pipe 100 mm dia, 3 mtr long with suitable size both end MS flange, threading, welding including providing rubber gasket, bolts, nuts and washers complete all as specified and as directed
S&F in repairs GI "Medium grade" column pipe 80 mm dia, 3 mtr long with suitable size both end MS flange, threading, welding including providing rubber gasket, bolts, nuts and washers complete all as specified and as directed
M&L cleaning of underground sewage sump by blocking the inlet/outlet flow from manholes, lifting the excess semi -solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scraping the internal wall / floor with wire brush to remove deposited scales, mud etc from the walls / floor by using suitable tools and plants, manually from the bottom of the tank and removing the same at a distance n.exc 50m from site where directed and depositing in collection pit duly spreading of bleaching powder in adequate quantity over sludge and adjoining area including necessary earthwork for excavation of pit and returning filling and opening the blocked manholes etc before normalising flow of sewer, complete all as specified and as directed for the following capacities :-
60,000 gallons capacity underground sewage sump (Location: Calcutta Gate sewage Sump)
40,000 gallons capacity underground sewage sump. (Location: Strand line & MAP Qtrs sewage sump)
30,000 gallons capacity underground sewage sump. (Location: George Gate sewage sump)
20,000 gallons Capacity underground sewage sump. (Location: East Gate, Treasury Gate, Water Gate & Golf Course sewage sump)
10,000 gallons capacity underground sewage sump. (Location: Chowringhee Gate sewage sump)
Supply and mixing Cultured Bacteriological solution for starting up of the system to treatment of sewage water complete all as specified and as directed. (Make- Bio-Clean, Micronz or equivalent make as approved by GE)
S&F in repair vertical scale type conventional water level indicator comprising of FRP graduated scale, indicator pin, counter weight, counter float, SS wire, bracket and wheel, duly fixed on OH reservoir complete all as specified and directed.
S&F Mild steel Pump set base frame suitable for 7.5 to 15 HP pump set including necessary dismantling of old PCC and provision of new PCC 1:2:4 type B1(20mm graded stone aggregate) foundation, Mild steel foundation bolt, nut & washers as in repair complete all as specified and as directed. (NOTE: Quoted rate is deemed to be inclusive of the cost of PCC foundation)
S&F in repair board printed on Flex sheet, size of board 145cm x 75cm with "Pump House contents written in and the size of letter not less than 15 mm height) on 6 mm thick BWR plywood base with wooden beading on all sides, fixed with screw on wall complete all as directed by Engineer-in-Charge.
SCH 'A' PART-III (EXTERNAL ELECTRIFICATION) S&F in repair galvanised iron strip 25mm X 4 mm with saddles porcelain/FRP insulators @ 1 metre c/c and fixing screws etc for roof conductors and down conductors above ground or buried in ground complete all as specified and directed.
S&F in repairs LED pathway luminare, 9/10 watt, in powder coated ERW MS tubular sections, with cylindrical diffuser on top complete, IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed. (Make : BAJAJ, Cat No: BGBOL 605 9W LED WW / CROMPTON, Cat No: LBLA-10-CDL / HALONIX, Cat No: HLOB-02-10-CW / SURYA, Cat No: SLE BL 9W-GLZ600 / EVEREADY,Model: IRIS or equivalent model in other makes specified in particular specifications) NOTE: Wire for conection of luminaire shall be measured and paid seperately.
S&F in repair LED decorative post top for 360 degree indirect light with IP 65 protection, resistant to impact and corrosion, glare free type complete all as specified and directed. [MAKE: Crompton Greaves, Cat No: LPTO-40-CDL (Model: MAPLE) / BAJAJ, Cat No: BRIL 40W LED WW (Model: TENCO) or equivalent model in other makes specified in tender) (NOTE : Wire for electrical connection of the luminaire shall be measured and paid seperately)
S&F in repairs LED aviation light luminarie integral type comprising aluminium housing with polycarbonate enclosure, incl fixing arrangement for fixing luminaire on top of OH tank incl fixing arrangement complete all as specified an directed. Make : Bajaj Cat No BGAV 302 LED / HALONIX, Cat No: HAVL 01 S 230 or equivalent model in other makes specified in particular specifications) NOTE: Wire for connection of luminaire shall be measured and paid seperately.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 32 X 6 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
-ditto- but with GI strip of size 25 x 5 mm
Supply and fix in repairs LED Street Light fitting 25W, in pressure die cast aluminium housing with lens and toughened glass cover with integrated constant current electronic driver, incl taking down existing fitting complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 110 lumen/watt (b) CRI not less than 70, (c) THD < 30% (c) having in built short circuit and surge protection upto 5 kV (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection grade: IP66 (NOTE: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
S&F in repair Bracket/Arm suitable for street light fittings, made out of 32 mm bore (light grade) GI pipe length not exceeding 1.5 metre long, fixed with 02 sets of flat iron clamp of size 32mm x 6 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
S&F in repairs PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs complete all as specified and as directed.
Taking out unserviceable LT panel board (of any size) and supply, install, commissioning and testing of outdoor type LT panel board, cubical type with canopy, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size not less than 850 mm x 750 mm x 550 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar of section 200 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at bottom portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, incl requisite supportling legs (of length 300 mm) of section 40 mm x 40 mm x 6 mm thick, and providing necessary foundation of the panel in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) complete all as directed by the Engr-in-Charge comprising of the following accessories :-
MCCB (Incoming) with thermal-magnetic release of capacity 63 Amps, 4 pole, 50HZ, 16 KA, Ics= 100% of Icu - 01 No. (Make: L&T, Cat No - CM90518OOHO / LEGRAND, Cat No: 4200 13 / HAGER, Cat No: HDA064Z /C&S, Cat No: CSESL125FMU4P63A)
MCCB (Outgoing) with thermal-magnetic release of capacity 40 Amps, 4 pole, 50HZ, 16 KA, Ics= 100% of Icu - 03 Nos. (Make : L&T, Cat No - CM90518OOFO / LEGRAND, Cat No: 4200 12 / HAGER, Cat No; HDA041Z /C&S, Cat No: CSESL125FMU4P40A)
Submersible Pump Starter, 3 phase, 415 Volts, 06 HP - 02 Nos (Make : C&S, Cat No: BE3-DXM204N312-PT / L&T, Cat No: SS95983DOAO or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / HPL)
Digital multifunction meter - 01 No
CT's 100/5A - 01 Nos
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All MCCB & Changeover to be connected internally with suitable size of copper strip.
Rounaq Enterprise
RAJ ENTERPRISE
PODDAR SALES CORPORATION
M A ENTERPRISES
SINHA ENTERPRISE
MARUTI ENTERPRISES
EAST COAST STANDARD PRODUCTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .