Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
23 May 2022, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Spl repair to LT Panel, timer switch LT OH line with Lt cable and connected work at 39 FAD and Kanjoli line under GE Bharatpur
2022_MES_519244_1
8131/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
As per tender document
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹91,000
Yes
6 Jun 2022
21 Apr 2022
27 May 2022
21 Apr 2022
23 May 2022
5 May 2022
22 Apr 2022 - 30 Apr 2022
Amount
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil.
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick.
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches. (Note :- Punned thickness shall be measured.)
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular to the cable in trenches complete all as specified and directed.
Taking down ACSR over head Aluminium conductor steel reinforced of any size all as specified and directed including stringing/ dismatling through RCC/Steel tubular poles, fixing on insulators, jumpering with aluminium binding wire etc complete all as specified and as directed by Engr-in-Charge incl taking out old unsv cross arms.
Taking out Under ground cable Aluminium conductor of any size complete all as specified and as directed by Engr-in-Charge
Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- 8.01 120 Sqmm 3.5 core
70 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 core
25 Sqmm 4core
16 Sqmm 4 core
10 Sqmm 4 core
10 Sqmm 2 core
Supplying and fixing in replacement 4Sqmm solid conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable circular flat from junction box to fitting complete all as specified and directed.
S&F 20 mm dia Unplasticised PVC pipes of pressure rating 10 Kgf/cm2 fixed on pole with MS clamps made out of 25 x 3 mm thick MS flat with the size of pole , nut, bolt etc at the interval of 1 meter all as specified and directed
Supply & lay G I tubing light grade in protection of cable at road crossing /hard standing/pole/wall fixed with clamps as per site requirement etc all as specified and directed for following sizes of pipe :- 11.01 40mm dia
50 mm dia
80 mm dai
100 mm dia
S&F 60 watts LED street light fitings new generation energy saving, environmental friendly, long life, versatile pressure die cast aluminium IP66 with 10KV surge protection road way, luminaire with high power LED as light source with warranty option of 5 years and suitable drivers etc and connecting with 4.0 sq mm multistranded aluminium conductor PVC insulated twin core weather proof cable from fittings to over head lines or to the jucntion box and fixing to complete all as specified and directed , Make :- Crompton ,wipro, Bajaj, Philips.
Supply, install, test and commissioning factory made HDPE/THERMOPLASTIC CABLE JUNCTION BOXES “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) with cable entry size of 10-25 sqmm with 4 No. 63 Amp busbar and 01 No 06 Amp SP MCB with cable glands including with flat iron clamps of size 30 x 6mm, nuts and bolts. Make Hansel /sintex/Fibox
S & F street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded as required including 02 Nos MS clamp of FI 40 x 6mm including nuts bolts & washers with fixing of LED street light complete necessary fixing arrangements on pole as directed.
S&F MCB's, with GI hardwaer of capacity MCB SP 240 volts 10-32 Amps
S&F MCB's, with GI hardwaer of capacity MCB SPN 240 volts 40 Amps
Supply and fixing of distribution board factory made and tested made of sheet metal enclosure powder coated suitable for mounting the MCB 240 volt/415V of the capacity 2 Way SPN with 200Amp rated busbar 240V (Single door type)
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised GI strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 5 mm thick angle iron and 0.75 m long for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front and back opening type with approx size for cable entry with double door shutter including locking arrangement as per manufacturer with 2 Keys. Incoming- (a) Change Over 4 pole 125 A , 415V, (b) MCCB 4 pole 125 A , 415V,16 KA adjustable type with magnetic release - 01 No.
Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 5 mm thick angle iron and 0.75 m long for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front and back opening type with approx size for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. Incoming- (a) MCCB 4 pole 200 A , 415V,36 KA adjustable type with magnetic release - 01 No.
Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars installed on percelain insulators, the panel shall be dust and vermin proof double door made of 2 mm CRCA MS sheet outer & inner 3.15 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 5 mm thick angle iron and 0.75 m long for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front and back opening type with approx size for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. Incoming (a) Change over 4 pole 125 A , 415V, - 01 No. (b) MCCB 4 pole 100 A , 415V,16 KA adjustable type with magnetic release - 01 No.
M& L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe up to 100mm dia complete Note :- GI pipe shall be measured and paid in separately
Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 5 mm thick angle iron and 0.75 m long for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front and back opening type with approx size for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. Incoming (a) MCCB 4 pole 400 A , 415V,35 KA adjustable type with magnetic release - 01 No.
Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 5 mm thick angle iron and 0.75 m long for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm. Front and back opening type with approx size for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. Incoming (a) MCCB 4 pole 200 A , 415V,35 KA adjustable type with magnetic release - 01 No.
Supply & fix in repair MCB 63 Amp, 4 Pole, fixed type breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified and directed by Engg-in-Charge.Make : L&T/ABB/Legrand
Supply & fix in repair MCCB 63 Amp, 4 Pole, fixed type breaking capacity 18 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified and directed by Engg-in-Charge.Make : L&T/ABB/Legrand
Supply & fix in repair MCCB 100 Amp, 4 Pole, fixed type breaking capacity 18 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.Make : L&T/ABB/Legrand
Supply & fix in repair MCCB 125 Amp, 4 Pole, fixed type breaking capacity 18 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.Make : L&T/ABB/Legrand
Supply & fix in repair MCCB 160 Amp, 4 Pole,adjustable type breaking capacity 25 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.Make : L&T/ABB/Legrand
Supply & fix in repair MCCB 200 Amp, 4 Pole,adjustable type breaking capacity 35 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.Make : L&T/ABB/Legrand
Supply & fix in repair MCCB 250 Amp, 4 Pole,adjustable type breaking capacity 35 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.Make : L&T/ABB/Legrand
Supply & fix in repair MCCB 400 Amp,4 Pole,adjustable type breaking capacity 35 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.Make : L&T/ABB/Legrand
M/s Ranaji Construction Co
PD GUPTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .