Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted. | |
| 2 | L2₹39.7 L+₹40,095.70 (1.02%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Higher rate quoted than L1 | |
| 3 | L3₹43.1 L+₹3.8 L (9.75%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted than L1 | |
| 4 | L4₹43.9 L+₹4.6 L (11.8%)Rejected-Finance 93 618 A MOHANTA PARA WARD NO 19 PO DIST JALPAIGURI PIN 735101 | JALPAIGURI | WEST BENGAL | 735101 | L4 | Rejected-Finance Higher rate quoted than L1 | |
| 5 | L5₹52.2 L+₹12.9 L (32.9%)Rejected-Finance OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L5 | Rejected-Finance Higher rate quoted than L1 |
Tender Value
₹49.1 L
EMD Value
₹98,300
Closing Date
26 Sept 2022, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_547317_1
8400-856/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
PANAGARH
Class D and Category b (i) (Low Tension Electric Works (Upto 1100 Volts))
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹98,300
Yes
24 Nov 2022
24 Aug 2022
27 Sept 2022
24 Aug 2022
26 Sept 2022
8 Sept 2022
Amount
M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths) complete all as specified and directed
M&L for Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required super ficial area n.exc 150 Sq Cm complete all as specified and directed
M&l two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primer incl;uding preparation complete all as specified and directed
S&F 605mm x 605mm Anodised aluminium snap grid frame work for false ceiling with all necessary aluminum angle & Tee arrangement with and incl fixing cleats screws etc complete all as specified in SSR and directed
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and complete all as specified and directed.
S&F for 6 mm thick 'E' board (non asbestos fibre) designer building boards fixed in aluminum frame work in ceiling flat or sloping with screws complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified and directed.
Removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punned down to a thickness of 18 cm complete all as specified and directed. (Note : Punned thickness shall be measured).
M&L for fly ash compact bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L for 80 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint complete all as specified and directed. (Make TATA/JINDAL/BANSAL).
M&L for 40 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint complete all as specified and directed. (Make TATA/JINDAL/BANSAL).
M&L for laying in trenches or passing through pipe 1100 volts grade, heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 240 Sqmm 3.5 core complete all as specified. (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant item.
All as per item No 14.00 mentioned here-in-above but 120 Sqmm 3.5 core complete all as specified and directed
All as per item No 14.00 mentioned here-in-above but 95 Sqmm 3.5 core complete all as specified and directed
All as per item No 14.00 mentioned here-in-above but 70 Sqmm 3.5 core complete all as specified and directed
All as per item No 14.00 mentioned here-in-above but 50 Sqmm 3.5 core complete all as specified and directed
All as per item No 14.00 mentioned here-in-above but 16 Sqmm 4 core complete all as specified and directed
All as per item No 14.00 mentioned here-in-above but 16 Sqmm 2 core complete all as specified and directed. Note: (For Ser No 14 to 20) : Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 50 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using galvanised iron strip 25×4mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 32 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate No 3 of SSR Part I, complete all as specified and directed and testing on completion. Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost.
Supply, commissioning and testing Outdoor type LT Feeder pillar Box, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 200 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - GE/Schneider/Seimens) (d) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCB-63 Amp, 2 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-08 No(Outgoing) (Make - GE/Schneider/Seimens)
Supply, commissioning and testing Outdoor type LT Distribution Panel, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-200 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - GE/Schneider/Seimens) (d) MCCB-160 Amp, 4 pole, 25KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - GE/Schneider/Seimens) (f) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - GE/Schneider/Seimens) (g) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-06 No(Outgoing) (Make - GE/Schneider/Seimens) (h) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (j) S & F digital voltmeter 0-500 V = 01 Nos
Dismantling existing steel or PCC poles/ steel poles, any size carefully including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc complete all as specified and directed.
Dismantling of cross arms of MS channel or angle iron sections etc complete and setting aside complete all as specified and directed
Dismantling ACSR conductor of any size from existing overhead service feeder etc complete all as specified and directed.
Dismantling of insulators any type any size complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique complete all as specified and directed.
M&L for wiring in repair for circuit/submain wiring alongwith earth wire in steel conduit (medium grade) with FRLS PVC insulated copper conductor, 2 x 1.5 Sqmm and 1 x 1.5 Sqmm single core (or Three core 1.5 Sqmm copper conductor) in surface complete including necessary MS clamps after taking down old unserviceable wiring of any condition complete all as specified and directed. (Note: 3 runs cable and steel conduit pipe will be measured as single unit)
S&F in repair junction box of minimum size 240 x 130 x 110mm made of polycarbonate with IP 65 degree of protection, dust proof, water tight, light weight, acid resistant, corrosion proof inslated & shock proof, fire retardant, self extinguishing, halogen & silica free non-toxic material, UV resistant, with internally ebbedded gasket fitted with required connector/ terminals for upto size 25 sqmm 4 core cable and hinged from Top and openable from down side and cable entry from sides or down including Glands and 10A SP MCB mounted on DIN rail for Street light connection complete all as specified and directed.
S&F in repair GI Bracket of dia 25 mm light grade with 1.2 mtr length including fixing the fitting removed for changing the bracket and connection with existing wire etc all as directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug,bolts,nuts and screws type 410 SP-31 (9.00 meters long) including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. (Note: PCC excavation shall be measured and paid seperately)
S&F LED Street light aluminium pressure die cast housing with toughened glass cover (IP 66 Rating), 45 Watt or equivalent complete all as specified and directed
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation for stay set /Pole/ FPB etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as coping of pole/panel including necessary form work as required complete all as specified and directed
A. R. ELECTRICALS
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
SOMIK DAS
M/S Ali Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .