Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹13.8 L+₹91,642.50 (7.12%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹14.4 L+₹1.5 L (11.7%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹14.4 L+₹1.6 L (12.1%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹15.7 L+₹2.8 L (21.7%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
13 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) CHABUA
GE(AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY SYSTEM AT TAMULBARI UNDER GE(AF) CHABUA
2020_MES_360779_1
271/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(AF) CHABUA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) CHABUA
₹26,000
Yes
29 Aug 2020
16 Jul 2020
15 Aug 2020
16 Jul 2020
13 Aug 2020
30 Jul 2020
60 days
Amount
Dismantling and taking down carefully the defective street light /security light fitting of any description / type (HPSV/HPMV/MH/LED/FTL/T5 fitting etc) and servicing/cleaning checking connections including M & L for PVC insulated copper conductor multistranded twin core 1 sqmm cable from connector block to choke and choke to lamp holder , approximately 0.30m length ,and reassembling ,and 2.5 sqmm twin core service wire from connector to junction box or OH conductor and refixing at its original location , including reconnections and testing / commissioning complete all as specified and directed. Note:- Choke, lamp and ignitor shall be measured and paid separately under relevant item.
Supply only VPIT ballast , heavy duty copper wound , suitable for HPSV/MH lamp 150 watt complete all as specified and directed.
Supply only VPIT ballast , heavy duty copper wound , suitable for HPSV/MH lamp 250 watt complete all as specified and directed.
Supply only VPIT ballast , heavy duty copper wound , suitable for HPSV/MH lamp 400 watt complete all as specified and directed.
Supply only MH Lamp tubular Single ended of capacity 150 watt complete all as specified and directed.
Supply only MH Lamp tubular Single ended of capacity 250 watt complete all as specified and directed.
Supply only MH Lamp For 400 watt fittings(Single ended) MHL 400 Watt SE Tubular complete all as specified and directed.
Supply only ignitor SP 230 V , 50 HZ suitable for 70 watt to 400 watt HPSV fitting complete all as specified and directed.
Supply only electronic ballasts for fluorescent tubes of capacity 2x24 watt complete all as specified and directed.
Supply only Tube Lights(Tube Rod) T5 24 watt 6500K (Lux) complete all as specified and directed.
Supply only LED driver of 40/60/70 watt complete all as specified and directed.
Dismantling and taking down carefully the defective High mast light fittings by mechanically/ manually and removing the unserviceable choke , MH Lamp tubular type any wattage and ignitor and repair/ replace it by new items and servicing/cleaning checking connections including M & L for PVC insulated copper conductor multistranded twin core 2.5 sqmm cable from connector block to choke and choke to lamp holder , approximately 0.30m length ,and reassembling , and refixing at its original location , including reconnections and testing / commissioning complete all as specified and directed. Note:- Choke, lamp and ignitor shall be measured and paid separately.
S&F in repair Ultra bright 20 W LED polycarbonate tube light single side connection with very high efficacy suited for installation in existing T8 tube light with G13 lamp holders to give glare free light all as specified and directed.
Supply & Fix in repair 20 Watt LED T5 batten fitting including with polycarbonate housing & integrated electronic driver, provision of PVC insulated sheathed round flexible with multi strand copper conductor of size 1.5 sqmm 3 core 1100 Volts grade complete all as specified and as directed.
Supply & Fix in repair 9 Watt LED T5 batten fitting including with polycarbonate housing & integrated electronic driver, provision of PVC insulated sheathed round flexible with multi strand copper conductor of size 1.5 sqmm 3 core 1100 Volts grade complete all as specified and as directed.
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminum stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension GI wire, one twin core cable flat or circular with size 4sqmm 2 core complete all as specified and directed.
Supply and replacement of 1100 volts grade heavy duty cable PVC insulated aluminum stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension GI wire, one twin core cable flat or circular with size 6sqmm 2 core complete all as specified and directed.
M & L for painting of Street light poles tubular type 9 mtr long in two coats of aluminum paint and one coat of red oxide as primer including writing of pole nos all as directed in Engr-in-Charge.
Taking down Existing MCCB of any type, Supply and fix in repair of MCCB, 4 Pole, 100 Amps , with breaking capacity 25KA , Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM),, Ics=100% Icu, AC 415 volt ,50 HZ all as directed.
Taking down Existing MCCB of any type, Supply and fix in repair MCCB, 4 Pole, 160 Amps , with breaking capacity 36KA , Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM),, Ics=100% Icu, AC 415 volt ,50 HZ all as directed.
Taking down Existing MCCB of any type, Supply and fix in repair MCCB, 4 Pole, 200 Amps , with breaking capacity 25KA , Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM),, Ics=100% Icu, AC 415 volt ,50 HZ all as directed.
Taking down Existing MCCB of any type, Supply and fix in repair MCCB, 4 Pole, 63 Amps , with breaking capacity 55KA , Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM),, Ics=100% Icu, AC 415 volt ,50 HZ all as directed.
Taking down Existing MCCB of any type, Supply and fix in repair MCCB, 4 Pole, 400 Amps , with breaking capacity 50KA , Thermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM),, Ics=100% Icu, AC 415 volt ,50 HZ all as directed.
Supply and fix in repair of MCB TPN, 63 Amps 10 KA breaking / rupturing capacity capacity 415 volt , 50 HZ conforming to IS 60898-1 including necessary connection with suitable size of copper cable complete all as directed.
Supply and fix in repair MCB single pole, 'C' curve, 10 KA, 6 - 32 amps complete all as specified and directed.
Supply and fix in repair of MCB single pole & neutral 'C' curve, 10 KA, 32 amps complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to 32x6mm GI strip, by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extent of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, included in rates.GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed up to minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- (i) Cost of GI strip dia 32x6 mm and protection pipe 40 mm dia is deemed to be included in rate quoted (ii) Excavation and returning filling of Soil any type is deemed to be included in rate quoted.
Supply and fix in replacement of steel wire rope Grade AISI 316, 7/19 with 6mm dia.
M&L cement concrete (1:3:6 ) type D2 using graded stone aggregate as in Copping of pole including necessary form work all as specified & directed.
M&L for pruning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Charge.
Taking out old/unserviceable UG cable of any description complete all as specified and as directed
Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanized steel strip or wired armoured with aluminum conductor of following size:-
(a) 16 sqmm 4 core
(b) 50 Sqmm 3.5 core
(c) 95 Sqmm 3.5 core
Excavation in trenches not exc 1.5 meter wide and not exc. 1.5 mtr in depth for laying of under ground cable, pole foundation and stays etc and getting out in hard / dense soil all as specified and as directed
Returning and filling in, including spreading and leveling, water and well ramming in layers not exc. 25cm all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed.
Supply & Laying of Sub-Class B Brick, well burnt laid breadth-wise along the length of cable laid in Trenches over sand cushion laid for UG cable protection complete all as specified and as directed
Sand cushioning and covering the under ground cable in trenches complete all as specified and as directed
Restring of over head (ACSR) conductor of any type and size to the extent of permissible sag including binding of conductor etc all as directed by Engineer-in-charge. Note: (i) Conductor span will be measured between centres of two poles. (ii) Each conductor in the span will be measured separately.
Dismantling carefully the existing unserviceable HT/LT overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as specified and as directed
supply and stringing ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminum tap and PG clamp etc of any size all as specified and as directed.
Dismantling of unserviceable existing cross arms made from channels, angles and unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and as directed
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or erected and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminum paint all as specified and as directed.
S&F in repair stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvanized stay plate 300mmx 300mm x 6mm and galvanized thimble including insulator 90x140mm all as specified and as directed. Note:- (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
S & F in replacement pin type, porcelain, vitreous, brown or green insulator including one galvanized mild steel spindle, steel washers and one galvanized nut of size 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed.
S & F in replacement of Loop type insulators ,vitreous porcelain, white , brown or green, large size with over all dimensions 140mm, clearance of hole 25.5mm including necessary cutting , jointing all as per directed by Engr-in- charge.
S & F in replacement of disc type, porcelain, vitreous, white or brown 145mm height, 255 mm dia ball and socket type complete with tension assembly clamps for conductor for 11000 volts grade single disc assembly complete all as specified & directed.
Horizontal Boring by Passing GI Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 METRE in a Single Length, complete all as specified and as directed.
Supply and fix in repair ,Install Testing & Commissioning complete self supporting totally enclosed single door, outdoor, LT bus bar box compartmentalized design, dust and varmin proof of size 450 mm(Height) x 450 mm(Length) x 450 mm(Width) suitable for 440 Volt 3 phase 4 wire system, 63 Amps TPN (01 Nos), MCB (03 Nos) made out of 3.15 mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprene rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Chromium plated and nuts, bolts ;and washers etc. The box shall be synthetic enameled painted and Copper bus bar 400 amps - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be provided with colour coded sleeves (red, yellow and blue) for three phases and black for neutral and including incoming/ outgoing cable holes at the bottom. The box shall be embedded with 75 x 6 mm MS Angle Iron frame and 50 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed by Engr in charge.
Dehydration/Filtration of Transformer Oil of 11KV distribution transformer by means of Centrifugal Filtration Plant to achieve the die-electric-strength of 56 KV for new insulating oil and 45 KV for existing oil at 2.5MM Gap all as specified and directed Note:- Toping of Transformer oil shall be measured and paid separately.
Supply & Pouring of New Transformer Oil for top up conforming to IS:335-1983 to achieve a Di-electric Strength up to 60 KV with Oil Testing Kit 4.0 mm thick to Top Up of the Transformer, complete all as specified and as directed.
S&F in replacement of vertical type air break switch, gang operated, triple pole, mechanically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing one all as specified and as directed.
S&F in replacement of drop out fuse unit, expulsion type for out door air break gang operated switch pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capacity suitable for current carrying capacity up to 100 Amps all as directed including taking down old one all as specified and as directed
M&L for end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminum conductor cable complete with jointing materials and accessories suitable for 3 core 95 Sqmm all as specified and directed.
M&L for cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint suitable for XLPE armoured aluminum conductor cable of size 3 core 95 Sqmm all as specified and directed.
Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp Suitable for 1100 volts all as specified and directed
Supply and fix in repair of LED flood light Luminaries 100 watt with pressure die-cast aluminum housing with heat resistance toughened glass & IP 65 protection, fixed with existing GI Bracket/Clamp, Nut, Bolt and washer , connection with 1.5 sqmm 3 run copper wire from junction box all as specified and directed.
Supply and fix in repairs after taking down the old unserviceable one, switch socket combination 5 Amp 5 pin flush type as specified and directed.
Supply and fix in repairs after taking down the old unserviceable one, switch socket combination 15 Amp 6 pin universal type as specified and directed.
Schedule of Credit
FREEZCON
STANDARD ELECTRIC WINDERS
M/s PRABIR ENTERPRISE
M/s HALDER ENTERPRISE
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .