Loading…
Loading…
Tender Value
₹4.7 L
EMD Value
₹10,000
Closing Date
23 Jun 2026, 3:00 pm6d left
Sh. Sudhir Kumar
Old Zonal MCD Office, Vishal Enclave, Rajouri Garden, West Zone, Delhi -110027.
Providing and Fixing of Street Light Fittings along with its allied accessories at various dark spots in Sainik Enclave ward no. 112 under West Zone.
2026_MCD_281080_1
E.E(Elect.)/WZ/2026-27/NIT No.13
Open Tender
Electrical Works
120 days
EE/Electrical-III Division West Zone.
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹10,000
16 Jun 2026
16 Jun 2026
23 Jun 2026
16 Jun 2026
23 Jun 2026
16 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 watt | 145 | Each | 1,744 | ₹2,52,880 |
| 1.002 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm | 480 | Metre | 104 | ₹49,920 |
| 1.003 | Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd. | 145 | Each | 982 | ₹1,42,390 |
| 1.004 | Supply of XLPE insulated PVC sheathed Al conductor Un-Armoured Cable 1.1 KV grade conforming to IS-7098 of following size:-2CX4 Sqmm | 350 | Metre | 47 | ₹16,450 |
| 1.005 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm | 350 | Metre | 36 | ₹12,600 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
1301GCC.pdf
Tender Documents • 1.74 MB
1301Schedule.pdf
Tender Documents • 2.39 MB
1301DNIT.pdf
Tender Documents • 0.48 MB
1301Conditions.pdf
Tender Documents • 2.44 MB
BOQ_328035.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid