Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 CrAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹8.5 Cr | L1 | Accepted-AOC Being L1 and reasonable |
| 2 | L2₹8.9 Cr+₹40.3 L (4.72%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹8.9 Cr+₹40.3 L (4.72%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹9.0 Cr+₹46.1 L (5.39%)Rejected-Finance | ₹9.0 Cr+₹46.1 L (5.39%) | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹8.1 Cr
EMD Value
₹7.3 L
Closing Date
8 Apr 2022, 6:00 pmClosed
Chief Engineer Bareilly Zone
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
PROVISION OF KLP ACCN FOR 522 ASC BN (PHASE-II OF II PHASES) AT MEERUT
2021_MES_491657_2
CEBZ / MRT / T-27 of 2021-22
Open Tender
Civil Works
Lump-sum
547 days
Meerut
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE (P) No 02 Meerut
₹7.3 L
Yes
29 Apr 2022
4 Mar 2022
13 Apr 2022
4 Mar 2022
8 Apr 2022
26 Mar 2022
5 Mar 2022 - 21 Mar 2022
Amount
SCHEDULE 'A' PART-I (BUILDING WORK)
Total amount of SCHEDULE 'A' PART-I (BUILDING WORK) (For details see Schedule 'A' Part-I in PDF folder)
Total amount of SCHEDULE 'A' PART-II-A (INTERNAL WATER SUPPLY) (For details see of Schedule 'A' Part-II-A in PDF folder)
SCHEDULE 'A' PART-IIB (INTERNAL WATER SUPPLY)
S&F brass chromium plated wall mixer fancy type for mixing hot & cold water screwed down for iron pipe suitable for 15 mm bore pipe, complete all as specified and directed.
S&F brass chromium plated central hole wash basin mixer, fancy type with or without lettered 'HOT' or 'COLD' with long screwed shank and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipe, complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-IIIA (INTERNAL ELECTRIFICATION) (For details see of Schedule 'A' Part-III-A in PDF folder)
SCHEDULE 'A' PART-IIIB (INTERNAL ELECTRIFICATION)
M&L for point wiring (concealed) complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded FRLS cable upto and incl working voltage 1100volts grade, PVC conduit, medium grade,ISI marked with fittings such as bend, tee, junction boxes elbows etc incl pressed steel terminal sunken boxes covered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws, cup washers and unsheathed copper conductor cable earth continuity wire connetctd to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area conductor and all other metal parts with earth dolly complete all as specified and directed for the following:-
One Light point controlled by one 5/6 Amp one way switch.
One fan/exhaust fan point controlled by one 5/6 Amp one way switch
One 3 pin socket outlet, 5 Amp controlled by one 5/6 Amp one way switch on the same board with other switches with cable 1.5 sqmm size.
One 3 pin socket outlet, 5 Amp controlled by one 5/6 Amp one way switch on independent board.
One bell/buzzer point controlled by one push button on the same board with other switches with cable 1.5 sqmm size.
M&L for point wiring (concealed) complete using 2.5 Sqmm PVC insulated unsheathed copper conductor, stranded FRLS cable, upto and incl working voltage 1100volts grade, PVC conduit,medium grade ISI marked with fittings such as bend, tee, junction boxes elbowsetc incl pressed steel terminal sunken boxes covered withcovered with 3mm thick plastic laminated sheet ISI marked top cover fixed with Brass screws, cup washers and unsheathed copper conductor cable, earth continuity wire connetctd to DBs/sunken boxes/fittings of size 2.5 Sqmm Cross sectional area conductor and all other metal parts with eath dolly for one three pin 15/16 Amp, socket out let point on independent board complete all as specified and directed.
Supply & Fixing Lamp holder/Batten holder with PVC/Polycarbonate body angular/straight fixed on plastic laminated sheet cover round shape 3 mm thick including 01 No LED filament lamp 9/10 W suitable for 230 V complete all as specified and directed.
M&L for sheet metal enclosure single pole and neutral with one 2 pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed. (Note : 4 Nos quantity of this item belongs to Sch 'A' Part-XII - Solar Water Heater)
Supply and fixing Vertical load line type TPN DB, 8 way, as per IS - 8623, IP-43 protection, universal mounting with suitable capacity copper bus bar with neutral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB TPN 125 Amp as incomer and MCB TPN 63/40 Amp as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed.
Supply and fixing Vertical load line type TPN DB, 4 way, as per IS - 8623, IP-43 protection, universal mounting with suitable capacity copper bus bar with nuetral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB TPN 63 Amp as incomer and MCB TPN 40/32 Amp as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed.
M&L for Distribution board double door 12 way for mounting MCBs/Isolators/ELCBS etc factory made conforming to IS: 13032 fabricated out CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link 200 Amps rated copper bus bar, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion, double door type with hinged & locking arrangement, flush to wall, IP-42 protection and label marking of incoming and outgoing circuit on all wayscomplete all as specified and directed. (Note:- DBs and MCBs/ISOlators etc shall be of same make)
M&L for Distribution board double door 8 way for mounting MCBs/Isolators/ELCBS etc factory made conforming to IS: 13032 fabricated out CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link 200 Amps rated copper bus bar, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion, double door type with hinged & locking arrangement, flush to wall, IP-42 protection and label marking of incoming and outgoing circuit on all wayscomplete all as specified and directed. (Note:- DBs and MCBs/ISOlators etc shall be of same make)
M&L for Distribution board double door 4 way for mounting MCBs/Isolators/ELCBS etc factory made conforming to IS: 13032 fabricated out CRCA sheet not less than 1.2mm thick fitted with DIN channel, neutral link 200 Amps rated copper bus bar, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion, double door type with hinged & locking arrangement, flush to wall, IP-42 protection and label marking of incoming and outgoing circuit on all wayscomplete all as specified and directed. (Note:- DBs and MCBs/ISOlators etc shall be of same make)
S&F minature circuit breaker single pole, 240 volts and 6 to 32 Amps current rating , B Series, 10 KA complete all as specifed and directed.
S&F minature circuit breaker single pole & neutral, 240 volts and 32 Amps current rating , breaking capacity 10 KA, 'C' series, complete all as specifed and directed.
S&F MCCB TPN 63 Amps current rating, 415 volts, 4 pole breaking capacity 16 KA complete all as specifed and directed.
S&F MCCB TPN 125 Amps current rating , 415 volts, 4 pole breaking capacity 16 KA complete all as specifed and directed.
M&L for sub main wiring with 2 run, single core 6 sqmm, PVC insulated PVC unsheathed stranded copper conductor FRLS cable 1100 volts, in and including PVC concealed/surface conduit,25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 6 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Three run of 6 sqmm copper cable measured as one unit.
M&L for sub main wiring with 2 run, single core 4 sqmm, PVC insulated PVC unsheathed stranded copper conductor FRLS cable 1100 volts, in and including PVC concealed/surface conduit, 25 mm or higher dia. ISI marked, medium grade complete with all conduit accessories/ fittings including extension earth wire with 4 Sqmm single core PVC insulated, unsheathed copper cable fixed along with sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed. Note :- Three run of 4 sqmm copper cable measured as one unit.
S&F bulk head LED light fitting 1X9W/10W LED with lamp including LED driver holder and connection wire three core copper conductor etc. complete all as specifed and directed.
Supply and fixing surface and wall mounted LED batten light fitting 230 volts, extruded aluminium housing provided for efficeint dissipation with polycarbonate diffuser amd integrated electronic driver with industrial grade heavy duty having THD<10% , ultra glass LED with very high efficeincy suitable for installation in existing T-8 fitting with G13 lamp holder, high lument output, PF>0.98, neutral white 20 watt 4 ft light fitting with lamp etc. complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor 1.5 sqmm cable wire, complete all as specified and directed. Make- Havells Cat Part No. LHEXACP7IN1J020/Make-Crompton Cat Part No. LSTLN-20 CDL/ Make-Wipro, Cat Part No.LL20-221-XXX-65NE3
Supply & fixing building decorative ultra slim aluminium LED light fitting 36 Watt with high lumen output environmental freindly energy efficeint ready to use high voltage protection upto 440 volts with pressure die cast aluminium housing, heat resistant toughened glass, IP-66 protection and impact resistance of IK07 with 10 KV buit in surge protection device, better optics distribution with integrated electronic driver including connection up with three core copper conductor 1.5 sqmm wire from ceiling rose to connector of street light complete all as specified and directed.
S&F Porch light fitting 15 watt square surface mounted LED flat panel, PDC aluminium housing and PMMA diffuser including lamp complete with all acessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specifed and directed. Make- Havells Cat Part No. LHEBGAP5IZ1W015/Crompton Cat Part No. LSDRMN-15W-CDL/NW/WW/ HPL Cat Part No. BRITO LED (R) 15W
Supply & fixing security light fitting, LED type, 36/40 Watt, pressure die cast aluminium housing, heat resistant toughened glass, IP-66 protection and impact resistance of IK07 with 10 KV buit in surge protection device, better optics distribution with integrated electronic driver including connection up with three core copper conductor 1.5 sqmm wire from ceiling rose to connector of street light complete all as specified and directed. (Make : Havells - Cat Part No LTESST36WLED/LS, Crompton Greaves - Cat Ref No ENDURACITYLITEPLATPLUSSL35WLEO757SASYBOPC, Wipro - Cat No LSTS-36-CDL-M, Philips - Cat No LR03-501-XXX-57
S&F GI pipe 'light grade' wall/pole mounting bracket of size 40 bore and 1.50 m long fixed to wall with and including nut, bolts and GI clamps of size 50x4 mm as required including two coats of synthetic enameled paint over a coat of primer, complete all as specifed and directed.
S&F blanking plate complete all as specifed and directed.
Supply & Fixing ceiling fan energy saving 5 star rated, with brushless direct current motor (BLDC) without regulator 230 volts single phase 1200mm sweep Energy saving fan Including canopy set,down rod and shackle assembly,Fan hook including providing three core copper conductor cable of size 1.5 Sq mm 3 core from fittings to ceiling rose or connector and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Make : Havells Model - Aeroking, Crompton High Speed Ceiling Fan, Orient Model - Energy Star)
S&F Exhaust fan energy saving 3 star rated, single phase 240 volts, 450 mm sweep heavy duty with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Make : Havells - Turbo Force SP, Orient 450mm Heavy Duty Exh (900 RPM) Grey / Crompton Greaves Industrial Fan)
S&F exhaust fan energy saving 3 star rated, single phase 240 volts, 300 mm sweep Metallic body with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/0.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. (Make : Havells - Ventil Air DS / Orient 300mm Air Flow / Crompton Greaves driftair 3 blade exhaust fan)
M&L for earthing completed with galvanized mild steel earth plate (electrode)600 x600x6.00 mm thik burried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcole dust mixed with salt ot a packed thickness of 15 cm all round the plate, using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI "light grade' pipe from upper end of earth plate upto main switch/control of the building including 20 mm dia gi pipe light grade as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber and Rcc pit cover with lifting handle, excavation earthwork including laying of GI pipe concealed in floor/ walls all as described in electrical plate No 5 of SSR Pt 1 complete all as specified and directed.
SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTH WORK)
Total amount of SCHEDULE 'A' PART-IV (SITE CLEARANCE AND EARTH WORK) (For details see of Schedule 'A' Part-IVA in PDF folder)
Total amount of SCHEDULE 'A' PART-VA (ROAD, HARD-STANDING AND CULVERT) (For details see of Schedule 'A' Part-VA in PDF folder)
SCHEDULE 'A' PART-VB (ROAD, HARD-STANDING AND CULVERT )
M&L for granular sub base (GSB II) 230mm thick (compacted thickness) consisting of laying and compacting well graded materials or prepared sub base as per MORTH guidelines, rolled and consolidation to required gradient and camber with power roller exc 8 n.exc 12 tonne, complete all as specified & directed.
M&L for 250 mm thick in two layers of 125mm each (compacted thickness) WMM, with coarse stone aggregate as per mix design IRC-109-1997, spread, rolled and consolidated to gradient with 8 to 12 tonne road roller complete all as specified and directed. (Note:- The quoted rate will be per unit of measurement for 250 mm thickness WMM in two layer of 125 mm thick)
Supply and fixing cat eye reflective type of metal body alloy of size 110mm x 128mm x 29.5mm with PAMA striplens reflector of model No. DA 971 fixed with and incl MS stud of suitable size as per manufacturer instructions complete all as specified and directed. (Make:- (a) Future Vista Mumbai (b) Jiya Engineering Company, New Delhi (b) Industrial Hardware Center, New Delhi)
M&L for preparing bituminous surfaces of road and marking 2.0 mm thick centre lines, stop lines, dashes, arrow etc. and the like n.exc 10 CM wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-VI A (SEWAGE DISPOSAL) (For details see of Schedule 'A' Part-VI A in PDF folder)
SCHEDULE 'A' PART-VI B (SEWAGE DISPOSAL )
Construction of Septic tanks for 50 users excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC slab covers including RCC precast manhole covers having 6mm plate embeded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc complete all as specified & directed.
Construction of Soakage well of size 3.0 mtr dia and 4.5 mtr effective depth, excavation in any type soil, foundation in PCC 1:3:6, brick work in walls of Honey combed and solid using sub class 'B' bricks in cement mortar 1:4, including RCC cover slab in M-25 and filling with brick bats, complete all as specified & directed.
Total amount of SCHEDULE 'A' PART-VII (AREA DRAINAGE) (For details see of Schedule 'A' Part-VII in PDF folder)
Total amount of SCHEDULE 'A' PART-VIII A (RAIN WATER HARVESTING) (For details see of Schedule 'A' Part-VIII A in PDF folder)
SCHEDULE 'A' PART-VIII B (RAIN WATER HARVESTING)
Boring holes 250mm dia complete with DTH comrotary method upto 60m depth below ground level in any type of soil incl removal of surplus soil upto 50m distance complete all as specified and directed.
Supply and lowering into bore 150mm dia PVC casing pipe perforated holes complete all as specified & directed.
Total amount of SCHEDULE 'A' PART-IX A (EXTERNAL WATER SUPPLY) (For details see of Schedule 'A' Part-IX A in PDF folder)
SCHEDULE 'A' PART-IX B (EXTERNAL WATER SUPPLY)
M&L for construction of brick masonry pit chamber of following internally size 450mm x 450mm x 450mm with angle iron frame of sizes 20mm x 25mm x 6mm and 4 mm thick mild steel plate cover painted with two coat of synthetic enemelled paint over a coat of red oxide primer after preparation of surface including locking arrangement and necessary excavation and earth work 80mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate over 100 mm thick hard core using broken in foundation brick work in cement mortor (1:6) and 15mm thick cement plaster in cement mortor 1:4 in internal surface of walls and outside upto 150 mm deep below ground level complete all as specified and directed at site.
Total amount of SCHEDULE 'A' PART-XA (EXTERNAL ELECTRIC SUPPLY) (For details see of Schedule 'A' Part-XA in PDF folder)
SCHEDULE 'A' PART-XB (EXTERNAL ELECTRIC SUPPLY)
M&L steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws type 410 SP-31, 09 metres long single swan neck type complete including painting two coats of aluminium paint over one coat of red oxide primer 3 Nos band straps with red post office box colour (300 mm wide 2 Nos each) synthetic enameled paint including one coat on steel surface embeded in concrete all as specified and directed.
Supply & fixing street light fitting, LED type, 70 Watt, 6000 K, pressure die cast aluminium housing, heat resistant toughened glass, IP-65/66 protection and impact and corresion resistant including thermal management in multiple optics distribution with integrated electronic driver and connecting up with three core copper conductor 1.5 sqmm wire from junction box to connector of street light complete all as specified and directed.
Supply, instalation, testing and commissioning outdoor LT cubical designed panel board KIOSK type weather , dust and vermin proof fabricated out of 3.15mm thick MS Sheet and angle iron 40mmx40mmx6 mm duly painted with two coat of stove enammel paint over a coat of red oxide with primer panel board suitable for AC 440 Volt , 3 phase, 4 Wire , 50HZ system all as specified and directed having following incoming and outgoing feeder control :- (a) INCOMING: - MCCB 100 Amp 4 pole, 415 Volt with rupturing capacity 16 KA - 01 No. (b) OUTGOING:- (i) MCB SPN 32 Amps, 230 V with rupturing capacity 10 KA - 05 Nos (ii) MCCB 63 Amp, 4 pole, 415 V with rupting capacity 16KA- 01 Nos. (Description Contd to BOQ Sl No 63.00)
Material and labour for earthing wth galvanized cast earth plate electrode of size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25 mtr below GL with top edge of earth plate not less than 1.5mtr below GL the earth plate surrounded by adequate quantity of charcoal dust and salt all as around as earth plate 15 cm by and GI strip 32 x 6mm as earth chamber to earth plate, CI funnel with wiremess fixed on water pipe and PCC 1:2:4 type B-1 duly reinforced with MS bar in lifting handle excavation earthwork including laying of GI pipe in walls etc all as directed in electirical plate No 3 of SSR Part-I complete all as specified and directed.
Material and labour for earthing wth galvanised cast earth plateof size 600x600x6mm thick burried vertically in ground to a depth not less than 2.25mtr below GL with top edge of earth plate not less than 1.5mtr below GL the earth plate surrounded by adequate quantity of charcoal dust and salt all as around as earth plate 15 cm by and GI earth wire 4mm dia as earth conductor, bolts and rivetted to earth plate one end protection with GI pipe light grade 15mm bore upto 2.4mtr on pole with flat iron clamp nut bolt complete earth work water pipe from earth chamber to earth plate, CI funnel with wiremess fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick precast RCC 1:2:4 type B-1 duly reinforced with MS bar 6mm dia @150cc both ways with 10mm dia MS bar in lifting handle excavation earthwork including laying of GI pipe in walls etc all as directed in electirical plate No 3 of SSR Part-I complete all as specified and directed.
M&L for pole box fabricated out of 1.8mm thick MS sheet having 3 Nos bus bar 50 Amp copper conductor mounted on insulators one No 20x3mm copper bus bar with 2 clamps of copper strip for earthing of the armoured of the cable, including one Nos of MCB SP 6 Amp complete with making holes for connecting cables etc nuts, bolts etc size of box not less than 100 x 200 x 80mm front openable hinged cover suitable for monting on steel using clamps nut bolt etc PVC adopters and PVC hose pipe upto cable trench for incoming and outgong cables, factory made duly painted with powder coating process complete all as specified and directed.
Boring holes under road/pavement by Trenchless technology using ultra sound technique machine including HDPE 150 mm dia pipe of 0.40 MPa working pressure complete all as specified and directed.
Supply and fix triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps complete all as specified and directed.
Supply and fix lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts complete all as specified and directed.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Total amount of SCHEDULE 'A' PART-XIA (WATER COOLER, REFRIGERATOR, DESERT COOLER) (For details see of Schedule 'A' Part-XII A in PDF folder)
SCHEDULE 'A' PART-XIB (WATER COOLER, REFRIGERATOR, DESERT COOLER)
Supply, installation and testing of refrigerator electric driven (Single phase), capacity 308 ltr, convertible fridge with smart inverter compressor, door cooling auto smart connect, multi air flow with door cooling 3 star rating , I micom temperature control eco friendly complete all as specified and directed. (Make - LG/Whirlpool/Godrej)
Supply installation and testing of refrigerator electric driven (Single phase), capacity 190 ltr, direct cool single door refrigerator BEE: 5 star rated IS: 1476 latest for direct cool puff insulation, copper coil, complete all as specified and directed. (Make - LG/Whirlpool/Godrej)
Supply and install desrt cooler electric driven single phase 240 volts having nominal air flow capacity of 4000 Cum per hour (or nearest size) complete with water circulating pump, Air exhaustfan, bottom water tank, body made out of MS sheet 1.2mm thick including fixing arrangement with angle iron 50x50x6mm bracket and suitable size of ply wood work and water connection with stop cock , valve complete all as specified and directed.
S&F Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 290V with output voltage 230 V with accuracy (+) or (-) 2.5% and of capacity 0.5 KVA time delay 4-6 Sec all as specified and directed.
S&F Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135V to 280V with output voltage 230 V with accuracy (+) or (-) 2.5% and of capacity 1.0 KVA with time delay relay 2-4 sec all as specified and directed.
Total amount of SCHEDULE 'A' PART-XIIA (HOT WATER SUPPLY (For details see of Schedule 'A' Part-XIIA in PDF folder)
SCHEDULE 'A' PART-XIIB (HOT WATER SUPPLY)
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. providing vent pipe of 4 mtr approx length of GI pipe medium grade or suitable length as per requirement with necessary fittings of 15mm dia complete with fixing and provision of 16mm dia bolts and nuts minimum length 150mm long for fixing of geyers complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. providing vent pipe of 4 mtr approx length of GI pipe medium grade or suitable length as per requirement with necessary fittings of 15mm dia complete with fixing and provision of 16mm dia bolts and nuts minimum length 150mm long for fixing of geyers complete all as specified and directed.
Sudhir Sharma Associates
VEE SONS BUILDERS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .