Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹33.6 L+₹2.3 L (7.20%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹36.8 L+₹5.5 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹46.5 L+₹15.2 L (48.4%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | L5₹47.2 L+₹15.9 L (50.8%)Rejected-Finance | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹47.9 L
EMD Value
₹96,000
Closing Date
8 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ng Rajesh Singh GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8489 REPAIR MAINT TO CERTAIN EM MARINE ASSETS AND OTHER CONNECTED ITEMS TO CRUISER WHARF JETTY AND ASSOCIATED AREAS AT ND MBI
2022_MES_552644_1
8489/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹96,000
Yes
25 Jan 2023
17 Sept 2022
10 Oct 2022
21 Sept 2022
8 Oct 2022
26 Sept 2022
17 Sept 2022 - 21 Sept 2022
Amount
M&L for point wiring (Work station for computer)complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etc fixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete necessary electric connection for each workstation point comprising of 03 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/ Plaza
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etc fixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 1.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete for One light/fan/bell point controlled by one 5A switch complete all as specified and directed for the following :- Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex
One light point controlled by one 5A switch
One 5A flush type switch socket point on same board
One 5A flush type switch socket point on independent board
M&L for in repair, point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI marked drawn through & including MS conduit with Accessories fixed on wall/ceiling/truss etc with metallic ISI marked terminal boxes surfacing on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth as earth dolly for:-
One light point controlled by one 5A switch
One 5A on independent board
S & F modular switch 1 way 6A all as specified and directed by EIC.
S & F modular switch 1 way 16A all as specified and directed by EIC.
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC.
S & F modular socket, 16A - 2/3 pin combined 2 modules all as specified and directed by EIC.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as directed.
S &F 20 Watt 4 FT, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver. Make-C & S CAT LTTB4F20WLED/W ,OR Equivalent to Philips/ Havells/CG
S &F 200 WATT LED Floodlight LED IP65 luminaire with high efficacy complete with all acessories and fixing arrangement.make-C & S CAT PART No LTEFH200WHPLED or Equivalent in Philips/Havells/CG
S&F Flame Proof Powersocket 15AMP with switch all as specified and directed suitable for Gas Group of IIA & IIB and Zone 1 & 2
S &F 140 WATT LED street light fitting made up of pressure die cast aluminium housing complete with all acessories.make-C &S CAT PART LTESST140WLED/LS or Equivalent in Philips/Havells/CG
S &F 40 WATT LED industrial light fitting IP65 luminaire with high efficacycomplete with all acessories and fixing arrangement.make-crompton CAT PART No LWVLT-40-CDL or Equivalent in Philips,CG,Havells
S &F CIMFR certified LED flameproof batten suitable for single T8 tube of 16W/20W. Recommended for Gas/Vapor group of IIA & IIB and Zone 1 & 2. IP65 Protected.Make- Crompton cat no. EXTN1LT8-16/20 and tube rod cat no. LTT8-20 or equivalent in Dudhir
S &F CIMFR certified LED flameproof batten suitable for twin T8 tube of 16W/20W. Recommended for Gas/Vapor group of IIA & IIB and Zone 1 & 2. IP65 Protected.Make- Crompton cat no. EXTN2LT8-16/20 and tube rod cat no. LTT8-20 or equivalent in Dudhir
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 607732 or equivalent in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 607731 or equivalent in siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 607730 or equivalent in siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 2 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 507791 or equivalent in siemens/GE.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 4 way, 440 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed. Make - Legrand cat part no 607735 or Equivalent in siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 8 way, 440 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed. Make - Legrand cat part no 607735 or Equivalent in siemens/GE (NOTE FOR ITEM NO., 16 TO 21 : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quoted rate)
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed.Make- Legrand/Siemens/GE
S & F in replacement of MCB,SPN 40 -63 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed.Make-Legrand,siemens,GE
S & F MCCB, 415 volts, four pole of cap 160 Amps, 25 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 420217or equivalent in siemens/GE
S & F MCCB, 415 volts, four pole of cap 200 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No 420218 or equivalent in siemens/GE
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sq mm 3.5 core. laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc shall be incl in quoted rate and no extra payment will be made for it.
S & F ACB, 415 volts, four pole of cap 1600 Amps, 50 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - L & T cat No SL96075 or equivalent in siemens/GE
S & F MCCB, 415 volts, four pole of cap 800 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No DPX³ or equivalent in siemens/GE
S & F MCCB, 415 volts, four pole of cap 630 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No DPX³ or equivalent in siemens/GE
S & F MCCB, 415 volts, four pole of cap 400 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No DPX³ or equivalent in siemens/GE
S & F MCCB, 415 volts, 3 pole of cap 400 Amps, 36 KA, ICS = 100% ICU, with fixed Thermal - Magnetic setting including spreader terminal/ thimble of suitable size and making connections complete all as directed. Make - Legrand cat No DPX³ or equivalent in siemens/GE
M&L for sub-main wiring with 2 runs of 4.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade non metallic PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction box, reducer etc as required, including one run of 4.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the disturbed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza
M&L for sub-main wiring with 2 runs of 6.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade non metallic PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction box, reducer etc as required, including one run of 4.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the disturbed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza
M&L for sub-main wiring with 4 runs of 10.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade non metallic PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction box, reducer etc as required, including 2 run of 6.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unserviceable sub main wiring and making good the disturbed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza
Supply and lay in repair 16 sqmm 4 core P.V.C. insulated unsheathed bright annealed bare conductor industrial cables for voltage grade upto 1100 V. as per IS 694:1990. and making connection complete all as directed. Note : 1. The cost of thimbles/lugs and cable gland etc shall be incl in quoted rate and no extra payment will be made for it.
SRISHTI CONSTRUCTIONS
shubham construction
AGRAWAL ASSOCIATES
RAJU ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .