| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L1 | Accepted-AOC Lowest tender accepted | |
| 2 | L2₹20.7 L+₹3.9 L (23.1%)Rejected-Finance H NO 2 ADARSH NAGAR ARJUN NAGAR NEAR MITTAL NURSING HOME AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹20.9 L+₹4.0 L (24.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹23.9 L+₹7.0 L (41.6%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹31.6 L+₹14.8 L (87.6%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Dec 2021, 6:00 pmClosed
GE (AF) Adm Area Agra
GE (AF) Adm Area Agra 282008
REPAIR AND MAINT OF LT UG CABLES SWITCH GEARS LT POLES LT PANELS BUS BAR CHAMBERS LT OVERHEAD LINES OVER HEAD ACSR CONDUCTOR STAY ASSEMBLY AND OTHER CONNECTED WORKS IN 4 AREA UNDER GE AF ADM AREA AT AF STATION AGRA
2021_MES_492084_1
8000-1922/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
Cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹50,000
Yes
19 Jan 2022
2 Dec 2021
30 Dec 2021
2 Dec 2021
28 Dec 2021
16 Dec 2021
2 Dec 2021 - 14 Dec 2021
Amount
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for laying for cables, errection of poles etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
All as per item No. 1 above but depth exc. 1.5 m but not exc. 3 m
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Material and labour for old size fly ash bricks class designation 75 Kgf/cm2, laid flat as in cable protection complete all as specified and directed.
Re-laying of old serviceable bricks item retreived from Sl No. 1 & 2 here-in before for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
M&L for local sand cushioning with dry and clean over and under the cable for protection of cable, 80 mm sand laid before laying the cable 150 mm sand after laying the cable and punned down complete all as directed
Material & Labour PCC 1:4:8 type D2 ( using 40 mm graded stone aggregate) as in foundation, filling and mass concrete incl necessary formwork complete all as specified and directed.
Material & Labour PCC1:2:4 Type B-1 (using 20 mm graded stone aggregate) as in coping of poles etc. complete all as specified and directed.
Material and labour for replacement of GI tubing light grade 100 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc complete all as specified and directed .
Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc complete all as specified and directed .
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc complete all as specified and directed .
Taking out old unserviceable LT UG cables of size 10 to 70 Sq mm 2/3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of sch.) complete all as directed.
Taking out old unserviceable LT UG cables of size 95 to 150 Sq mm 3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of sch.) complete all as directed.
Re-Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 2/3.5/4 Core (Item retreived from item 13 here-in-before) laid in trenches or fixed on wall/floor/poles after removing fault complete all as specified and directed.
Re-Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 95 to 150 Sqmm 3.5/4 Core (Item retreived from item 14 here-in-before) laid in trenches or fixed on wall/floor/poles after removing fault complete all as specified and directed.
S&L including connecting XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 120 Sq mm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
All as per Srl Item No 17 here-in-before but size of cable 95 Sqmm, 3.5 Core complete all as spd and directed.
All as per Srl Item No 17 here-in-before but size of cable 70 Sqmm, 3.5 Core complete all as spd and directed.
All as per Srl Item No 17 here-in-before but size of cable 50 Sqmm, 3.5 Core complete all as spd and directed.
All as per Srl Item No 17 here-in-before but size of cable 35 Sqmm, 3.5 Core complete all as spd and directed.
All as per Srl Item No 17 here-in-before but size of cable 25 Sqmm, 3.5 Core complete all as spd and directed.
All as per Srl Item No 17 here-in-before but size of cable 16 Sqmm, 4 Core complete all as spd and directed.
All as per item No 17 here in before but size 10 Sqmm, 2 core complete all as spd and directed.
M&L for replacement of existing unsv cable end terminal joints with new cable end terminal joints (heat shrinkable) any type along Pole/panel etc. suitable for XLPE LT 1100 Volts aluminium conductor cable of size 120-185 Sqmm 3.5 core and testing after jointing. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint.
All as per item No. 25 but for cable size 50-95 Sqmm 3.5 core
All as per item No. 25 but for cable size 16-35 Sqmm 3.5/4 core
All as per item No. 25 but for cable size 10 Sqmm 2 core
M & L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100 mm bore GI tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 400 Amps copper bus bar 04 Nos, 4 way with fixed on insulator welded with iron angle of size 50x50x5 mm thick grounting in floor, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Cat Part No IHBC040004 of Make-Havells or equivalent in Legrand/L&T
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 250 Amps copper bus bar 04 Nos, 4 way with fixed on insulator welded with iron angle of size 40x40x5 mm thick grounting in floor, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Cat Part No IHBC025004 of Make-Havells or equivalent in Legrand/L&T.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos, 4 way with fixed on insulator welded with iron angle of size 40x40x5 mm thick grounting in floor, 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Cat Part No IHBC020004 of Make-Havells or equivalent in Legrand/L&T.
M&L for replacement of existing unsv Bus Bar Panel with new Bus Bar Panel of capacity 100 Amps copper bus bar 04 Nos, 4 way with fixed on insulator fixed on pole with bracket made out of FI of size 25 mm x 3 mm- 02 Nos including providing nut, bolt and washers, all as specified and directed. Cat Part No IHBC010004 of Make-Havells or equivalent in Legrand/L&T.
Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e. Two Pole/ Four structures, outdoor-substation yards & other Misc E/M installations etc.) soft and loose soil including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as directed
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 meter long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be painted with two coats of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background including taking out old unsv pole complete all as specified and directed.
Restringing (without taking down) of existing ACSR’s conductors and earth wires including cradles, of any description, size & shape and in any position, as in LT/HT overhead lines, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc. including testing complete all as specified and directed. The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in position of cradles. (ii) Old serviceable spacers of ACSR conductor shall be reused and fixed as directed by Engineer-in-Charge.
Material & labour pin type porcelain, vitreous, white, brown or green insulator including one GI nut bolt 100 mm height 65 mm dia for 1100 Volt complete including taking down old unserviceable insulator all as specified and directed.
Material & labour Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts for 1100 Volt 100 mm height & 115 mm dia with GI straps 31x5 mm & dia of volt 14 mm complete including taking down old unserviceable insulator complete all as specified and directed.
M&L for danger notice plate of size 20 cm x 15 cm x 1.6 mm thick mild steel sheet viterous enamelled white with letters figures and conventional skul and bones in signal red colour and fixed with MS clamps, bolts, nuts and washers of approved size for LT , 415 volts complete all as specified and directed.
M&L for stay assembly using GI stay rod 20 mm dia complete with stay plate of mild steel of size 300 x 300 x 6.00 mm thick, stay bow, loop insulator, stay wire, stay clamp, nuts, bolts etc. complete all as specified and shown in Electrical Plate No 1 . (Necessary earth work and PCC shall be measured and paid seperately) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) in foundation for stay etc. including necessary form work etc complete all as specified and directed.
Disconnecting of GI earthing strips/earth wire leads of any size, any description and in any postion from test point carefully and testing the earth resistance of any type of lightening conductor earthing with the help of earth tester of suitable capacity and recording Ohm value in the register as per proforma approved including cleaning vegetation/wild growth surrounding the earth pit and removing dust/deposited soil from earth pit. NOTE :- (i) The contractor will arrange Earth Tester, all T&P & accessories required for recording the reading. (ii) The contractor shall arrange for watering of the earth pit through watering pipe in the earthing to improve the resistance. The common salt min 10 Kgs for each earthing pit shall be mixed with the water at site and filled/dropped in earthing through warering pipe as per site condtion and as directed. The water for this purpose shall be made available by the deptt. at the nearest available source but contractor shall make his own arrangement for drawing water from this source. (iii) The record of resistance value of each earthing alongwith date of testing should be maintained on register as per format approved.
M&L for prepration of old painted surface of steel tubular poles of 8.5/9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background and cleaning /cutting the grass/bushes at a radius of 2 mtr surrounding the pole all as directed.
Supply and fixing in replacement of existing old un-serviceable Earth continuity conductor of size 32 x 6 mm GI strip fixed to wall and batton or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. complete all as specified and directed.
M&L in replacement of existing unsv MCCB 400 Amps current carrying capacity 36 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 250 Amps current carrying capacity 36 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 160 Amps current carrying capacity 25 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 125 Amps current carrying capacity 25 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 63 Amps current carrying capacity 16 KA, AC 415 Volts Ics= 100% Icu, four pole with magnetic/ thermal adjustable type setting complete all as specified and directed.
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. (ii) Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
Cutting the existing road/ Hard standing for passing pipe and making good the disturbed surfaces by using 15 mm thick 1:4:8 in foundation type D-2 (using 40mm graded crushed stone aggregate) as in mass concrete complete all as specified exists complete all as specified.
M&L in replacament of existing old unsv earthing complete with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
M&L in replacament of existing old unsv earthing complete with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised strip 32x6 mm size as earthing lead by means of bolts, nuts, check nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN copper bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN copper bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN copper bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity upto 1000 Amps, 415 V, 50 Hz of Make Legrand/ CG/ L&T/ABB/ Havells/ C&S or other existing make, strip opening the Air circuit breaker, inspecting the parts for serviceability/ overhauling complete and carrying out the following repairs/ maintenance:- a) Cleaning the insulation parts including bushings with CTC solution. b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual. c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts. d) Check arc chutes for damage. e) Clean and lubricate the operating mechanism with a light machine oil for pins and bearings and with a non-hardening grease for the wearing surfaces. Adjust breaker operating mechanism all as per manufacturer's instructional manual. f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Checking control device free for operation. j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional. NOTE : Spare parts replaced shall be maesured and paid seperately as supply only.
Supply only CTs suitable for air circuit breakers of rating 630 Amps to 1000 Amps as all per existing of Make:- Legrand/ CG/ L&T/ABB/ Havells/ C&S
Supply only auxiliary contact block suitable for air circuit breakers of rating 630 Amps to 1000 Amps as all per existing of Make:- Legrand/ CG/ L&T/ABB/ Havells/ C&S
Supply only Adaptor Type Terminals (for 415 V) suitable for air circuit breakers of rating 630 Amps to 1000 Amps (for 415 V) suitable for air circuit breakers of rating 630 Amps to 1000 Amps as all per existing of Make:- Legrand/ CG/ L&T/ABB/ Havells/ C & S
Supply only Shunt trip/ closing coil (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 630 Amps to 1000 Amps as all per existing of Make:- Legrand/ CG/ L&T/ABB/ Havells/ C & S
Supply only Under voltage trip Device for air circuit breakers of rating 630 Amps to 1000 Amps as all per existing of Make:- Legrand/ CG/ L & T/ABB/ Havells/ C & S
S&L/ fixing in replacement of unsv 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections twin core cable of size 10 Sqmm complete all as specified and directed .
S&F in replacement digital type Amp-meter including suitale ratio of CT, rating 0-400 Amps, 96 x 96 mm complete all as spd and directed.
S&F in replacement Digital type Volt-meter of size 96 x 96 mm, capacity 0- 500 volts complete all as spd and directed.
Supply and fixing in replacement LT air circuit breaker manual draw out type 600 Amps rating 4 pole equipped with service power micro processor based protection release with short circuit over load and earth fault protection and breaking capacity 50 KA comprising the following items:- 1. Over Current Release 2. Arc Chute 3. Charging Handle 4. Pole Unit 5. Terminal assembly ,Construction of ACB 6. Moving Contact assembly 7. Push Button “OFF” 8. Push Button “ON” 9. Shunt Trip Coil 10. Cradle Unit 11. Safety Shutter 12. Terminals 13. Pad lock facility for safety shutter 14. Control Terminals 15. Position Indication Switch (Optional) 16. Mounting Holes 17. Spring charge indicator 18. ACB ON OFF indicator 19. ACB connection status indication 20. Cradle rake in / out slot 21. Lifting Plate
M&L for Straight through joints heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor under ground cable 3.5 core 25 to 35 sqmm and testing after jointing complete all as specified and as directed.
All as per item No. 70 here-in-before but for cable 3.5 core 50 sqmm
All as per item No. 70 here-in-before but for cable 3.5 core 70 sqmm
All as per item No. 70 here-in-before but for cable 3.5 core 95 sqmm
M&L Gravel, hard and preferably rounded with specific gravity not less than 2.5, free from clay, sand, loam and organic impurities of any kind, Acid solubility not more than 10.00 % for gravel sizes 10mm or larger and 5.00% solubility for gravel sizes smaller than 10mm, Particle size 20 mm-30 mm, complete all as specified and directed.
Supply and fixing HDPE liner sheet heavy duty black colour, min thick ness 250 micron including jointing and 10 cm over lap material complete all as specified.
Taking down existing MS articles and S&F new Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed.
H.S.Kochhar n Sons
Balaji Associate
Industrial Traders
M/s Sumer Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .