Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹35.0 L+₹20,349 (0.58%)Rejected-Finance 4 S1 A 405 ZODAIC MARATHON NEXZONE NH4 PALASPE PHATA REES RAIGAD MAHARASHTRA 410 206 | RAIGAD | MAHARASHTRA | 410206 | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹35.3 L+₹44,349 (1.27%)Rejected-Finance B BLOCK 2 3 RAM BACHAN V B NAGAR PIPE ROAD KURLA W MUMBAI 400070 | MUMBAI SUBURBAN | MAHARASHTRA | 400070 | L3 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 4 | L4₹36.2 L+₹1.4 L (4.11%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 5 | L5₹40.1 L+₹5.3 L (15.3%)Rejected-Finance | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | NOEL ENGINEERS L5 | Genius Construction Co. L3 | S S ENTERPRISES L6 | OM SAI POWER SYSTEMS L1 | JANKI ENTERPRISES L2 | Sri Krishna Construction L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for replacement of LT panel board, factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, rain shed 15 cm all around, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:-
(a) MCCB 4 pole, 400 Amps, 36 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider.
(b) On Load Changeover switch 400 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells.
(c) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -08 Nos, Make-Legrand/Siemens/Schneider.
(d) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos.
(e) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos.
(f) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases.
(g) Tinned copper bus bar strips made of copper suitable for 600 Amps (01Set of four)
(h) Making good the disturbed surface if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. | 3 | Each Job | 2,80,000 ₹8,40,000 | 2,25,000 ₹6,75,000 | 1,80,000 ₹5,40,000 | 2,10,000 ₹6,30,000 | 1,75,000 ₹5,25,000 Lowest | 2,20,000 ₹6,60,000 |
| 2.00 | M&L for replacement of LT panel board, factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, rain shed 15 cm all around, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:-
(a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider.
(b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos, Make-Legrand/Siemens/Schneider.
(c) Power contactor 4 pole 40 Amp, 415 V - 02 No. Make: Schneider, L&T or Legrand.
(d) Analog time switch 3 module - 02 No. Make: Schneider, L&T or Legrand.
(e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos.
(f) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos.
(g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases.
(h) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four)
(j) Making good the disturbed surface if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. | 1 | Each Job | 1,20,000 ₹1,20,000 | 1,10,000 ₹1,10,000 | 1,60,000 ₹1,60,000 | 64,001 ₹64,001 Lowest | 1,00,000 ₹1,00,000 | 1,20,000 ₹1,20,000 |
| 3.00 | Taking down old unserviceable and Supply, install, testing and commissioning of Lift Machine Room LT panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including air louvers at both side, Top canopy/shed, including disconnecting cable connections from old panel and connecting in new installed panel with provisions of thimble/lugs and including PCC on 1:2:4 type B-1 for fixing panel at old panel place complete all as specified and as directed comprising of the following-
(a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer)
(b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -02 Nos
(c) RCBO 4 pole, 63 Amps, 300 mA, 415 volt -03 Nos
(d) MCB SPN 10-32 Amps 10 KA - 04 Nos
(e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos
(f) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos.
(g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases.
(h) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four)
(j) Making good the disturbed surface if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. | 7 | Each | 95,000 ₹6,65,000 | 75,000 ₹5,25,000 | 1,00,000 ₹7,00,000 | 67,000 ₹4,69,000 | 1,00,000 ₹7,00,000 | 65,500 ₹4,58,500 Lowest |
| 4.00 | Taking down old unserviceable and Supply, install, testing and commissioning of Lift Machine Room LT panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including air louvers at both side, Top canopy/shed, including disconnecting cable connections from old panel and connecting in new installed panel with provisions of thimble/lugs and including PCC on 1:2:4 type B-1 for fixing panel at old panel place complete all as specified and as directed comprising of the following-
(a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer)
(b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos
(c) RCBO 4 pole, 63 Amps, 300 mA, 415 volt -04 Nos
(d) MCB SPN 10-32 Amps 10 KA - 04 Nos
(e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos
(f) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos.
(g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases.
(h) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four)
(j) Making good the disturbed surface if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. | 7 | Each | 90,000 ₹6,30,000 | 95,000 ₹6,65,000 | 1,00,000 ₹7,00,000 | 77,000 ₹5,39,000 Lowest | 1,00,000 ₹7,00,000 | 82,000 ₹5,74,000 |
| 5.00 | Taking down old unserviceable and Supply, install, testing and commissioning of LT panel mounted on wall alongwith suitable wall mounting arrangement,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including air louvers at both side, Top canopy/shed including disconnecting cable connections of existing panel & connecting in new installed panel with provisions of thimble/lugs complete all as specified and as directed comprising of the following-
Incoming
(a) MCCB 4 pole, 100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos.
Outgoing
(b) RCBO 4 pole 63 Amps 415 volt 300 mA - 02 Nos.
(c) MCB SPN 10-32 Amps 10KA - 02 Nos
Other Accessories:-
(d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc- 1 No.
(e) Phase indicator lamp R,Y & B - (01 Set oet three).
(f) Copper Bus bar,200 Amps Rated - R,Y,B & N - (01Set of four)
(g) Making good the disturbed surface of panel room if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. | 12 | Each | 72,000 ₹8,64,000 | 50,000 ₹6,00,000 | 60,000 ₹7,20,000 | 29,500 ₹3,54,000 Lowest | 42,000 ₹5,04,000 | 46,000 ₹5,52,000 |
| 6.00 | Taking down old unserviceable and M&L for LT FPB, weather proof, vermin proof, double door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Coper busbar strip of 800 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x5 mm thick, powder coated painting incl foundation in PCC 1:3:6 type C2 all as specified & Directed consisting of following :-
(a) MCCB 4 pole, 630 Amps, 36 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer)
(b) MCCB 4 pole, 250 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos.
(c) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos.
(d) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos.
(e) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos.
(f) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases.
(g) Tinned copper bus bar strips made of copper suitable for 800 Amps (01Set of four)
(h) Making good the disturbed surface if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. | 1 | Each Job | 2,90,000 ₹2,90,000 | 2,85,000 ₹2,85,000 | 3,50,000 ₹3,50,000 | 3,75,000 ₹3,75,000 | 2,50,000 ₹2,50,000 Lowest | 3,20,000 ₹3,20,000 |
| 7.00 | Taking down old unserviceable and Supply, install, testing and commissioning of Lift LT panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including disconnecting cable connections from old panel and connecting in new installed panel with provisions of thimble/lugs and including PCC on 1:2:4 type B-1 for fixing panel at old panel place complete all as specified and as directed comprising of the following-
(a) MCCB 4 pole, 160 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer)
(b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos.
(c) MCB 4 pole 40 Amps 10 KA - 02 Nos
(d) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos.
(e) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos.
(f) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases.
(g) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four)
(h) Making good the disturbed surface if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. | 2 | Each | 82,000 ₹1,64,000 | 75,000 ₹1,50,000 Lowest | 1,80,000 ₹3,60,000 | 75,000 ₹1,50,000 Lowest | 75,000 ₹1,50,000 Lowest | 90,000 ₹1,80,000 |
| 8.00 | Taking down old unserviceable and Supply and fix On load change over switch in sheet metal enclousers 4 pole of capacity 63 Amp, 415 V, 50Hz including terminal shrouds, source separator and phase barriers conforms to IEC 60947-3 suitable for horizontal as well as vertical mounting on wall surface including disconnecting existing cables from changeover switch & reconnecting to new changeover switch complete all as dierected. | 29 | Each | 3,200 ₹92,800 Lowest | 7,000 ₹2,03,000 | 12,000 ₹3,48,000 | 6,850 ₹1,98,650 | 5,000 ₹1,45,000 | 6,700 ₹1,94,300 |
| 9.00 | Taking out Old U/S MCB DB TPN alogwith all MCB/RCBO and Supply and fixing of MCB TPN DB 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 100 A Copper Busbar for phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 DB's for provision for 63/100 Amps MCB TPN as incomer and SP/TP MCB's as outgoing complele all as specified and directed. | 40 | Each | 2,200 ₹88,000 | 1,700 ₹68,000 Lowest | 8,000 ₹3,20,000 | 8,500 ₹3,40,000 | 2,000 ₹80,000 | 6,000 ₹2,40,000 |
| 10.00 | Supply and fix MCB 4 pole 63A, 10kA, 415V complete all as per specificed and directed. | 40 | Each | 1,500 ₹60,000 | 1,350 ₹54,000 Lowest | 1,800 ₹72,000 | 1,750 ₹70,000 | 2,000 ₹80,000 | 3,000 ₹1,20,000 |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
6 Nov 2025, 6:00 pmClosed
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
SPECIAL REPAIRS REPLACEMENT OF LT PANEL OF LIFT MACHINE ROOM AT RS COLABA AREA OF NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2025_MES_735385_1
8580
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NW NAVY NAGAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR
₹77,800
27 Dec 2025
15 Oct 2025
8 Nov 2025
15 Oct 2025
6 Nov 2025
29 Oct 2025
15 Oct 2025 - 6 Nov 2025
Amount
M&L for replacement of LT panel board, factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, rain shed 15 cm all around, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- (a) MCCB 4 pole, 400 Amps, 36 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider. (b) On Load Changeover switch 400 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (c) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -08 Nos, Make-Legrand/Siemens/Schneider. (d) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. (e) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. (f) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases. (g) Tinned copper bus bar strips made of copper suitable for 600 Amps (01Set of four) (h) Making good the disturbed surface if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
M&L for replacement of LT panel board, factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, rain shed 15 cm all around, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- (a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider. (b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos, Make-Legrand/Siemens/Schneider. (c) Power contactor 4 pole 40 Amp, 415 V - 02 No. Make: Schneider, L&T or Legrand. (d) Analog time switch 3 module - 02 No. Make: Schneider, L&T or Legrand. (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. (f) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. (g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases. (h) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four) (j) Making good the disturbed surface if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Taking down old unserviceable and Supply, install, testing and commissioning of Lift Machine Room LT panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including air louvers at both side, Top canopy/shed, including disconnecting cable connections from old panel and connecting in new installed panel with provisions of thimble/lugs and including PCC on 1:2:4 type B-1 for fixing panel at old panel place complete all as specified and as directed comprising of the following- (a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) (b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -02 Nos (c) RCBO 4 pole, 63 Amps, 300 mA, 415 volt -03 Nos (d) MCB SPN 10-32 Amps 10 KA - 04 Nos (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos (f) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. (g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases. (h) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four) (j) Making good the disturbed surface if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Taking down old unserviceable and Supply, install, testing and commissioning of Lift Machine Room LT panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including air louvers at both side, Top canopy/shed, including disconnecting cable connections from old panel and connecting in new installed panel with provisions of thimble/lugs and including PCC on 1:2:4 type B-1 for fixing panel at old panel place complete all as specified and as directed comprising of the following- (a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) (b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos (c) RCBO 4 pole, 63 Amps, 300 mA, 415 volt -04 Nos (d) MCB SPN 10-32 Amps 10 KA - 04 Nos (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos (f) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. (g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases. (h) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four) (j) Making good the disturbed surface if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Taking down old unserviceable and Supply, install, testing and commissioning of LT panel mounted on wall alongwith suitable wall mounting arrangement,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including air louvers at both side, Top canopy/shed including disconnecting cable connections of existing panel & connecting in new installed panel with provisions of thimble/lugs complete all as specified and as directed comprising of the following- Incoming (a) MCCB 4 pole, 100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos. Outgoing (b) RCBO 4 pole 63 Amps 415 volt 300 mA - 02 Nos. (c) MCB SPN 10-32 Amps 10KA - 02 Nos Other Accessories:- (d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc- 1 No. (e) Phase indicator lamp R,Y & B - (01 Set oet three). (f) Copper Bus bar,200 Amps Rated - R,Y,B & N - (01Set of four) (g) Making good the disturbed surface of panel room if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Taking down old unserviceable and M&L for LT FPB, weather proof, vermin proof, double door made out of 3mm thick CRCA sheet, CPRI approved, out-door type (IP-54) suitable for 3 phase, 4 wire, 415 volts, with Coper busbar strip of 800 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x5 mm thick, powder coated painting incl foundation in PCC 1:3:6 type C2 all as specified & Directed consisting of following :- (a) MCCB 4 pole, 630 Amps, 36 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) (b) MCCB 4 pole, 250 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos. (c) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos. (d) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. (e) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. (f) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases. (g) Tinned copper bus bar strips made of copper suitable for 800 Amps (01Set of four) (h) Making good the disturbed surface if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Taking down old unserviceable and Supply, install, testing and commissioning of Lift LT panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 300 Amps rated copper bus bar (All in equal size), top and bottom cable entry with proper size glands including disconnecting cable connections from old panel and connecting in new installed panel with provisions of thimble/lugs and including PCC on 1:2:4 type B-1 for fixing panel at old panel place complete all as specified and as directed comprising of the following- (a) MCCB 4 pole, 160 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) (b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -04 Nos. (c) MCB 4 pole 40 Amps 10 KA - 02 Nos (d) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. (e) Digital type Ammeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. (f) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue - 1 set (set of three) as in incoming phases. (g) Tinned copper bus bar strips made of copper suitable for 300 Amps (01Set of four) (h) Making good the disturbed surface if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Taking down old unserviceable and Supply and fix On load change over switch in sheet metal enclousers 4 pole of capacity 63 Amp, 415 V, 50Hz including terminal shrouds, source separator and phase barriers conforms to IEC 60947-3 suitable for horizontal as well as vertical mounting on wall surface including disconnecting existing cables from changeover switch & reconnecting to new changeover switch complete all as dierected.
Taking out Old U/S MCB DB TPN alogwith all MCB/RCBO and Supply and fixing of MCB TPN DB 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 100 A Copper Busbar for phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 DB's for provision for 63/100 Amps MCB TPN as incomer and SP/TP MCB's as outgoing complele all as specified and directed.
Supply and fix MCB 4 pole 63A, 10kA, 415V complete all as per specificed and directed.
S&F ISI marked 63A, 300mA, 415V, 4 pole RCBO for AC applications, conforming to IS:12640 (Part2)-2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP20 protected lower terminals and sliding shutters, all complete as specified and directed
S&F MCB SPN, 10-32Amp, 10 KA, 230 Volt complete all as per specificed and directed.
M & L for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point with 40mm dia light grade GI Pipe as protection of GI strip, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engr-in-Charge. Quoted rate included all necessary earth work, PCC and GI strip including light Grade GI pipe upto 7.5 mtr from earth electrode all as specified SSR.
JANKI ENTERPRISES (BID ID -3473902)
Genius Construction Co. (BID ID -3465262)
Sri Krishna Construction (BID ID -3473931)
NOEL ENGINEERS (BID ID -3463766)
S S ENTERPRISES (BID ID -3465530)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
TENDERDOCUS.pdf
Tender Documents • 0.70 MB
BOQ_823479.xls
BOQ • 1.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .