| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being lowest bidder after deducting the sch of credit of Rs. 172247.00 | |
| 2 | L2₹25.1 L+₹2.5 L (11.3%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance 2ND LOWEST BIDDER AFTER DEDUCTING SCH OF CREDIT RS 172247/- | |
| 3 | L3₹27.9 L+₹5.4 L (23.8%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST BIDDER AFTER DEDUCTING SCH OF CREDIT RS 172247/- | |
| 4 | L4₹29.1 L+₹6.6 L (29.1%)Rejected-Finance WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance 4TH LOWEST BIDDER AFTER DEDUCTING SCH OF CREDIT RS 172247/- |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(Army) Dhar Road
GE(Army) Dhar Road
REPAIR MAINTENANCE OF EXTERNAL LT ELECTRIC SUPPLY SYSTEM AND CONNECTED ITEMS AT SAMNABANJ RC PEAK AND BATTAL UNDER GE ARMY DHAR ROAD UDHAMPUR
2023_MES_598375_1
8069/NIT-26/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE(Army) Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE(Army) Dhar Road
₹80,000
Yes
30 Aug 2023
25 May 2023
26 Jun 2023
26 May 2023
24 Jun 2023
9 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
All as per item No 1 above but depth exceeding 1.5 meter and not exceeding 3 meter complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
All as per item No 09 above but of size 50 mm bore.
All as per item No 09 above but of size 80 mm bore.
All as per item No 09 above but of size 100 mm bore.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Taking out existing worn out/old PVC insulated cable in 3.5 core of 185 sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Taking out existing worn out/old PVC insulated cable in 3.5 core of 95 sqmm to 35 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Taking out existing worn out/old PVC insulated cable in 3.5/2 core of 16 sqmm to 10 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 35 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed.
-- do-- as per item no. 17 above but size 185 sq mm 3.5 core
-- do-- as per item no. 17 above but size 50 sq mm 3.5 core
-- do-- as per item no. 17 above but size 16 sq mm 4 core
-- do-- as per item no. 17 above but size 10 sq mm 2 core
-- do-- as per item no. 17 above but size 95 sq mm 3.5 core
Supply & laying HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 95 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Supply and laying or fixing or passing through twin core, 1100 volts grade heavy duty cable with PVC insulated flate / round aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 6 Sqmm 2 core nominal cross section complete all as specified and directed.
S&F Sheet metal enclosure box 3.15 mm thick CRCA sheet with power coated paint (CPRI Approved) double door outdoor type including solid aluminium bus bar of capacity 400 amp 4 Nos strip alongwith MCCB 4 Pole 250 Amps 25 KA with locking arrangements, enclosure box to be fixed on plinth foundation including MS angle/ chanel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrengement on pole/wall , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed.
Taking down old UNSV panle any type and shape and supply , installation, testing and commissioning as in repair busbar chamber, outdoor type, double door,KIOSK type of size (0.6x0.60 x 0.25) Mtrs, factory made, front & back openable, properly welded MS angular supported with Stand made out of 50x50x6 mm thick angle iron having 4 Nos legs of 2 feet height with CRCA steel sheet Minimum of 3 mm thick, duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint, CPRI Approved with locking arrangements with & including 4 Nos Aluminium busbar of rating 250 Amp on base insulators including necessary platform and grouting of panel as per manufecturer's instructions after demolition of chamber as existing at site complete all as specified and as directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for heat shrink type end joint out door type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm
S&F Cable jointing kit for 11 KV (Earthed) grade cable for heat shrink type end joint in door type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm
Dimentling and taking down old/unsv cross arms, bracing, supports etc complete all as specified and directed.
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Dismetling and taking down old/unsv ACSR conductor any size complete all as specified and directed.
S/F ACSR conductor incl jointing with existing conductor and straining on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as dercted. Note :- Size of aluminium conductor as per site requirement will be directed by Engineer-in-Charge.
Taking out existing worn out/old PVC insulated cable in 3 core of 95 Sqmm size of 11000 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES compitent staff complete in all respect and as directed at site.
Dimentling and taking down old/unsv insulator of any type any size from pole/stay complete all as specified and directed.
S&F Disc type insulator 11000 volts porcelain, vitrous 145mm high and 255 mm dia ball and socket type white, brown or green single disc with tension clamp for conductor for working pressure voltage 11000 V including dismentling taking out unsv one from Pole.
S&F pin type 11000 Volts, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 150mm height and 150 mm dia for 11000 volts grade including dismentling taking out unsv one from Pole all as specified and directed.
M/L for Stay assy using 16mm dia galvanised rod complete all as shown in electrical plate No 1 of SSR Part I incl dismentling unsv one all as specified and directed. (Clamps, loop insulator, earth work, PCC measured separately)
S/F for stay wire using galvanised steel strand of 7/3.15mm complete with necessary binding incl dismentling taking down unserviceable one all as specified and directed
M & L triple pole mechanically operated GOD mounted on insulators and steel frame with operating mechanism worked from ground level 11000 volts grade of current carying capacity up to 200 Amps complete incl removing the existing U/S one.
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600x600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32x6mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 50 mm dia light grade GI tubing for protection of GI Strip 32x6mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion
Supply and fixing GI strip 32 x 6 mm for extension of earth and connected to equipment or panel complete all as specified and directed by Engineer-in-Charge.
M&L for restraining of overhead ACSR conductor of any size 03 to 5 conductor on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumpering connection and insulator binding with aluminium conductor providing required T&P all as specified and directed
S&F MCCB 400 Amps 4 Pole, 35 KA, 415 V, 50 Hz adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
All as per item No 44.00 here in before but MCCB 250 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 45.00 here in before but MCCB 200 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 46.00 here in before but MCCB 160 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 47.00 here in before but MCCB 100 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 48.00 here in before but MCCB 63 Amps 4 Pole, 16 KA, 415 V, 50 Hz complete all as specified and directed.
M&L for painting and write pole number of steel tubular pole with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT/HT OH line from above copping to top of pole and marking with alternate white and yellow/black paint strip 30 cm wide (5 Nos) with synthetic enamelled paint all as specified and directed.
M&L for trimming of branches of trees touching LT/HT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr.
Dismentling taking down unserviceable flood/stree/gate light fitting any type any capacity from Pole/Building for replacement complete all as specified and directed.
S&F LED Street light fitting 60 Watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
S&F LED Street light fitting 90 Watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.
S&F energy saviing environmental friendly, long life exclusive innovative die-cast aluminium IP-66 LED flood light of 120 Watt 5700K with high power LED as light source source complete all as specified and directed.
S&F Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of required size with 02 Nos mild steel clamp 50mm x 50mm and sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer incl dismentling taking down unsv complete all as specified and directed.
S&F of lightning arrestor, distribution class, System voltage-11KV, min rating-10KV, Discharge cap-10 KA, Line discharge class-1 complete with bracket and connection complete all as specified and directed.
Supply, Errecting and fixing of true Vertical position steel tubular swaged pole complete with coat iron base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of red oxide as specified type 410 SP 31 (9.00 Mtr long) incl taking down old unserviceable pole all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
Supply, Errecting and fixing of true Vertical position steel tubular swaged pole complete with coat iron base plate, finial taper plug, bolt, nuts and screw,weld and reduced section and logitudional weld Seam through out entire length of pole including 2 coats of black bituminious paint through out intrnely and externely up to planting depth and remaining exterior portion of pole with two caot of aluminium paint over a coat of red oxide as specified type 410 SP-55 (11.00 Mtr long) incl taking down old unserviceable pole all as specified and directed at site. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately.
Supply & laying HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 120 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Servicing, Maint and repairing of Voltage Stablizer of capacity 30 KVA by disconnecting the incoming and outgoing connection strip opening the stablizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor and dimmer as per existing size - 03 No, (b) Voltmeter 0 to 500 Volts with switch. Make : AE. - 01 No, (c) Voltage on off adjusting switc h (Auto control Switch), (d) Supply, filling and pouring transformmer oil after dehydrating the sump - 75 Ltrs, (e) Roller Wheels as per existing size - 01 Nos, (f) Voltmeter 0-300 Volts - 03 Nos
Servicing, Maint and repairing of Voltage Stablizer of capacity 63 KVA by disconnecting the incoming and outgoing connection strip opening the stablizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor and dimmer as per existing size - 03 No, (b) Voltmeter 0 to 500 Volts with switch. Make : AE. - 01 No, (c) Voltage on off adjusting switc h (Auto control Switch), (d) Supply, filling and pouring transformmer oil after dehydrating the sump - 100 Ltrs, (e) Roller Wheels as per existing size - 01 Nos, (f) Voltmeter 0-300 Volts - 03 Nos
Supply and fix single automatic street light switch suitable for 3KW load complete with two numbers infrared sensor based NATURE SWITCH for automatic switching of street/ security lights with one number two pole power contractor 40 Amps (Type MU40-2P, Cs90119) with coil voltage 220/240 V and incoming MCBs single pole - 01 No, outgoing MCBs single pole - 01 No of rating 32 Amps & circuit wiring with single core multi standard of size 10 sq mm lighting switch operation should be based on natural light lux level, Required luminance level for switching ON is < 30 Lux. The sensor (one service and one stand by) should also have part night operation facility for 4,5,6---11&12 hours. The sensor along with suitable power contractor (S), incoming and outgoing MCBs should be enclosed in a pole/wall mountable enclosure made of Rust proof, Electric shock proof, termite proof and FR grade confirming to IP66 complete all as specified and directed by Engineer in charge.
Servicing, Maint and repairing of Voltage Stablizer of capacity 100 KVA by disconnecting the incoming and outgoing connection strip opening the stablizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor and dimmer as per existing size - 03 No, (b) Voltmeter 0 to 500 Volts with switch. Make : AE. - 01 No, (c) Voltage on off adjusting switc h (Auto control Switch), (d) Supply, filling and pouring transformmer oil after dehydrating the sump - 150 Ltrs, (e) Roller Wheels as per existing size - 01 Nos, (f) Voltmeter 0-300 Volts - 03 Nos
K S BUILDERS
PROACH ASSOCIATES BUILDERS & ENGINEERS
LUXMI ELECTRONIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .