Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC | ₹19.2 L Quoted ₹19.5 L | L1 | Accepted-AOC FOUND LOWEST AND REASONABLE BID |
| 2 | L2₹21.0 L+₹1.6 L (8.05%)Rejected-Finance BHAVANI KRUPA GANDHI CHOWK PULGAON 442302 | WARDHA | MAHARASHTRA | 442302 | ₹21.0 L+₹1.6 L (8.05%) | L2 | Rejected-Finance OTHER THAN LOWEST TENDER |
| 3 | L3₹21.0 L+₹1.6 L (8.07%)Rejected-Finance PULGAON | ₹21.0 L+₹1.6 L (8.07%) | L3 | Rejected-Finance OTHER THAN LOWEST TENDER |
| 4 | L4₹21.3 L+₹1.8 L (9.42%)Rejected-Finance | ₹21.3 L+₹1.8 L (9.42%) | L4 | Rejected-Finance OTHER THAN LOWEST TENDER |
| 5 | L5₹21.7 L+₹2.2 L (11.4%)Rejected-Finance | ₹21.7 L+₹2.2 L (11.4%) | L5 | Rejected-Finance OTHER THAN LOWEST TENDER |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Jul 2021, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD CAMP PULGAON PIN 442303
REPAIR REPLACEMENT OF UG CABLE LT OVERHEAD LINE AND OTHER CONNECTED WORKS AT RESIDENTIAL AND DEPOT AREA UNDER GE PULGAON
2021_MES_451973_1
8923/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
PULGAON
As per NIT
8 documents required · 8 mandatory
₹500
GE PULGAON
₹40,000
Yes
1 Sept 2021
16 Jun 2021
13 Jul 2021
16 Jun 2021
7 Jul 2021
30 Jun 2021
16 Jun 2021 - 28 Jun 2021
Amount
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, wtering, and well ramming complete all as specified and as directed.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point complete all as specified and as directed.
M & L for sand cushioning with dry and clean sand over and under the under ground cable in trenches , ducts for cable protection incliding levellling and consodilation complete all as specified and as directed. (Note Punned thiickness shall be measured.)
Supply and laying brick sub class "B" having minimum compressive strength 75 kg/sqcm laid in trenches for cable protection etc complete all as specified and as directed.
Re- laying of brick off size laid in trenches for cable protection etc complete all as specified and as directed.
Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof including taking out of brick layer and sand from trenches complete all as specified and as directed.
Re laying LT UG cable armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of following sizes complete all as specified and as directed.
All as per Item No. 8 ... But for 25 Sqmm 3.5 Core
All as per Item No. 8 ... But for 35 Sqmm 3.5 Core
All as per Item No. 8 ... But for 50 Sq mm 3.5 core
All as per Item No. 8 ... But for 70 Sq mm 3.5 core
All as per Item No. 8 ... But for 120 Sq mm 3.5 core
All as per Item No. 8 ... But for 185 Sq mm 3.5 core
All as per Item No. 8 ... But for 240 Sq mm 3.5 core
Supply, laying and testing LT XLPE insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of following sizes complete all as specified and directed by EIC. Note:- 1. Excavation and earth work, sand cushioning, brick pipes, clamps, and cable joint shall be measured and paid separetely under respective items :-
All as per Item No. 9 ... But for 25 Sqmm 6 Sq mm 2 core
All as per Item No. 9 ... But for 10 Sq mm 4 core
All as per Item No. 9 ... But for 16 Sqmm 4 Core
All as per Item No. 9 ... But for 25 Sqmm 3.5 Core
All as per Item No. 9 ... But for 35 Sqmm 3.5 Core
All as per Item No. 9 ... But for 50 Sq mm 3.5 core
All as per Item No. 9 ... But for 70 Sq mm 3.5 core
All as per Item No. 9 ... But for 120 Sq mm 3.5 core
All as per Item No. 9 ... But for 185 Sq mm 3.5 core
All as per Item No. 9 ... But for 240 Sq mm 3.5 core
Supply & laying in repair 50 mm bore galvanized steel tubing "light grade" with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed
All as per Item No. 10 ... But for 80mm bore
Re- stretching/Stringing only existing ACSR of any size on LT pole including binding the ACSR with insulators, aluminium binding wire,rejumpring of Cut point, complete all as specified and as directed. (Note : (i) One length shall be measured for complete 4 to 6 conductors & GI wire.)
Boring of holes under road/railway crossing, pavement, hardstanding by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4mpa working pressure without any damage to existing structure and making it good to match with the adjoining surfaces/structure for cable passing complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009) connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) 50mm thick cover reinforced with 8mm dia TMT bars @ 100mm c/c both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm bore GI medium grade earth lead protection pipe, complete all as specified and directed.
Supply & Fixing in repair/Replacement PVC line seperator suitable for 2 way on LT over head line complete all as specified and directed.
Supply & Fixing in repair/Replacement PVC line seperator suitable for 3 way on LT over head line complete all as specified and directed.
Supply & Fixing in repair/Replacement PVC line seperator suitable for 4 way on LT over head line complete all as specified and directed.
M&L for cable jointing kit in replacement of 1.1KV grade cable for heat shrink type straight through joint and accessories suitable for 3.5 Core XLPE armoured Al conductor cable of Size 25 to 50 Sqmm complete all as specified and directed. ( Make: Reychem/3M or any equivalent)
All as per Item No. 18 ... But for 70 to 150 Sqmm
All as per Item No. 18 ... But for 185 to 240 Sqmm
M&L for tesitng of faulty LT cable at CAD Pulgaon by using LT voltage. Testing kit installed on movable vehicle complete all as specified and directed by EIC (Note : This job includes cost of vehicle transport from Nagpur to Pulgaon and back)
Dismantling and taking out the existing unserviceable (damaged/broken) or serviceable tilted steel tubular electric pole of any type and size, from ground after necessary excavation & breaking of concrete foundation encasing the pole and removal from site complete all as specified and directed.
Supply & fixing steel tubular pole 410 SP-31 (9 metres long) complete with cast iron base plate finial taper plug nuts, bolts and washers all as specified in IS including the following:- (a) Excavation in post holes in any types of soil, return filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) Painting of poles with one coat of red oxide primer and two coat of aluminum paint before fixing and one coat of aluminum paint after fixing complete embedded portion. (Note : PCC in foundation to ground level and coping/plinth block shall be measured and paid for sepearately under item No 21 and 22 respectively.)
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete all as specified and directed.
PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work complete all as specified and directed.
Material and labour in repair replace for MS cross arms, bracing, stiffeners, support clamps and back plate fabricated from structural steel sectionAngle iorn,flat of size and thicness, including nuts, bolts washers, welding binding cold or hot, drilling holes for bolts in any shape or as directed including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Preparation of old painted surfaces of steel tubular poles 8.5/9 Mtr long including cross arms protection pipe and painting one coat of aluminium paint from 2.1 mtr above ground level to top of pole and cross arms and protection pipe and painting of bottom area of pole upto 2.1 mtr from ground level with synthetic enamel paint in alternate bay ( 30 cm wide) with black and yellow paint including writing poles numbers in white letter on black ground complete all as specified and directed.
Material and Labour in repair in replace pin type porcelain vitreous, white, brown or green insulator including one GI mild steel spindle, two GI washers and one GI nut 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
Material and labour in repair shackle type porcelain insulator vitrous wihite, brown or green of size 75mm height, 90mm dia for working pressure 1100 vlots including GI mild steel straps 31x3mm washer, insulators, nuts, dia of bolt 12mm complete all as specified and directed.
M&L for cutting / trimming of tree branches upto 50mm girth all around LT over head line and making free/safe all around 2 mtr LT OH line by taking all precautions and dispose of tree branches to nearest disposal point complete all as specified and directed.
S&F in repair 1100 volts grade 4 Sqmm twin core flat heavy duty cable PVC insulated,PVC sheet with solid aluminium conductors, multistranded served with an inner sheathing of PVC tape and overall PVC shathed in service connections complete all as specified and directed. (Make-Polycab /Plaza/Diamond ISI mark.)
All as per Item No. 31... But for 6 sqmm 2 core
All as per Item No. 31... But for 10 sqmm 2 core
S&F of MCCB in replacement TPN 63 to 100 amps 16 KA 415 volts complete all as specified and directed including taking out u/s old one.
S&F of MCCB in replacement TPN 125 amps 16 KA 415 volts complete all as specified and directed including taking out old one
S&F of MCCB in replacement TPN 160 amps 36 KA 415 volts complete all as specified and directed including taking out old one
S&F of MCCB in replacement TPN 200 amps 36 KA 415 volts complete all as specified and directed including taking out old one
S&F of MCCB in replacement TPN 250 amps 36 KA 415 volts complete all as specified and directed including taking out old one
M and L for dismantling and lowering of existing 22m high mast pole and light fitting by crane and after repair oiling, greasing of rope of high mast light and pole in suitable working condition and testing complete all as specified and as directed. (Note :- Rate includes crane vehicle from work shop to pulgaon)
M/s Dara Constructions, Pulgaon
M/S Maa Durga Constructions,Pulgaon
SHRI RANI SATI TRADERS
M/S L M Chourasia
MAHARASHTRA ENTERPRISES
M/s Prakash Agencies
RAJ ENTERPRISES
Bidder Name
M/S L M Chourasia
RAJ ENTERPRISES
SHRI RANI SATI TRADERS
MAHARASHTRA ENTERPRISES
M/s Dara Constructions, Pulgaon
M/S Maa Durga Constructions,Pulgaon
M/s Prakash Agencies
M/s MM TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .