Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.9 L+₹2.1 L (6.88%)Rejected-Finance 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.1 L+₹6.3 L (21.0%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not approved |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Sept 2022, 6:00 pmClosed
GE (AF) Utarlai
GE (AF) Utarlai PB No.11 Barmer 344001
REPAIR/MAINT OF SUMMER APPLIANCES, PACKAGE TYPE AC, DUCTABLE AC AND DESERT COOLERS AT AF STN UTARLAI
2022_MES_544572_2
8321/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹70,000
Yes
15 Dec 2022
29 Aug 2022
1 Oct 2022
30 Aug 2022
24 Sept 2022
5 Sept 2022
Amount
M & L for servicing of ductable split type AC of capacity 3 / 3.5 / 4 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge. Note : Refrigerant required for topping (R22 / R-134/ R410(a) shall be maesured and paid for separately as "supply only rates" under respective item of BOQ here-in-after
Supply only Refrigerant gas R 22/ R-32 in company sealed cylinder complete all as directed by Engr-in-charge
Supply only Refrigerant gas R-134/410 in company sealed cylinder complete all as directed by Engr-in-charge
Replacement of following unserviceable item in ductable split type AC :- a) Blade for condensing fan motorof capacity 3/4 TR
b) Foam type insulating flexible pipe & air tight outer tapping fitted on ACs of any capacity for suction / discharge copper tubes
S&F in replacement of condenser fan moter of ductable split type AC of 4 TR capacity as per existing make and model, all as directed by Engineer-in-Charge.
S&F in replacement of blower fan moter of ductable split type AC of 4 TR capacity as per existing make and model, all as directed by Engineer-in-Charge.
S & F in replacement of starting capacitor, for ductable split type AC of capacity 4 TR. Complete all as directed.
S&F in repairs harmatically sealed Compressor (Sealed Unit) of window / split type AC 2 TR capacity, single phase, 220 volt as per existing make and model including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge.
S&F in repairs harmatically sealed Compressor (Sealed Unit) of window / split type AC 1.5 TR capacity, single phase, 220 volt as per existing make and model including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard.
S & F in replacement of Industrial Plug and socket with plastic plug of 20 A rating SPN 250 Volts with MCB SP 20 AMP complete all as specified and directed.
S&F in repairs trasformer windings suitable for 5 KVA voltage stabilizer all as specified and directed.
S&F in repairs trasformer windings suitable for 4 KVA voltage stabilizer all as specified and directed.
S&F in repairs PCB circuit with relay, internal wiring, on/off switch, 5/15 amp sockets, input cable lead 4 sqmm 3 core (1.5 m long), limit switch etc suitable for 5 KVA voltage Stabilizer all as specified and directed.
S&F in repairs PCB circuit with relay, internal wiring, on/off switch, 5/15 amp sockets, input cable lead 2.5 sqmm 3 core (1.5 m long), limit switch etc suitable for 4 KVA voltage Stabilizer all as specified and directed.
S&F in replacement of display unit suitable for 5 KVA voltage stabilizer as per existing make and model all specified and directed.
S&F in replacement of display unit suitable for 4 KVA voltage stabilizer as per existing make and model all specified and directed.
M&L for sub main wiring with two runs of 4 sqmm single core PVC insulated but unsheathed FRLSH copper conductor 1100V drawn through and including rigid heavy duty PVC casing capping 25 mm dia with conduit accessories including 4 sqmm PVC insulated but unsheathed FRLSH copper conductor used as earth wire all as directed by Engr -in- charge. Note :- (i) Rates are deemed to be included chases of conduit and making holes in wall/floor for passing in or through conduit and making good the distrub surface (ii) Two run of 4 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of 4sqmm as earth wire will be measured as a one run lenth.
M&L for sub main wiring with two runs of 6 sqmm single core PVC insulated but unsheathed FRLSH copper conductor 1100V drawn through and including rigid heavy duty PVC casing capping 25 mm dia with conduit accessories including 6 sqmm PVC insulated but unsheathed FRLSH copper conductor used as earth wire all as directed by Engr -in- charge. Note :- (i) Rates are deemed to be included chases of conduit and making holes in wall/floor for passing in or through conduit and making good the distrub surface (ii) Two run of 6 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of 6sqmm as earth wire will be measured as a one run lenth.
M & L for servicing of window type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge. Note : Refrigerant required for topping (R22 / 134) shall be maesured and paid for separately
S&F in repairs PVC fan blade suitable for condenser of window type AC of any capacity. Complete all as specified and directed.
S&F in repairs relay only suitable for window type AC 1.5/02 TR capacities complete all as specified and directed.
S & F in repairs wiring kit of window type AC complete with lugs, thimble complete all as specified and directed.
S&F in repairs condensor fan moter of window type AC of 1.5 / 2 TR capacity as per existing make and model, complete all as directed by Engineer-in-Charge.
S&F in repairs thermostat suitable for window type AC 1.5/2 TR capacity.
M & L for servicing of split type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge. Note : Refrigerant required for topping (R-22 / R-134/R410(a) shall be maesured and paid for separately.
Replacement of following unserviceable item in Split type AC 1.5/2 TR :-
Running Capacitor 1.5 Mfd
Running Capacitor 2 Mfd
Running Capacitor 2.5 Mfd
Running Capacitor 3 Mfd
Running Capacitor 4 Mfd
Running Capacitor 6 Mfd
Running Capacitor 12 Mfd
Running Capacitor 36 Mfd (Clip type)
Running Capacitor 45/50 Mfd
PVC Blade for condensing fan motor
S & F in replacement of Starting capacitor (ISI Marked), 36 Mfd complete all as specified and directed.
S & F in replacement of starting capacitor, 100-120 Mfd suitable for AC of capacity complete all as specified and directed.
S&F in repairs condensor fan moter of split type AC suitable for 1.5/2.0 Ton capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs blower fan moter of split type AC suitable for 1.5/2.0 Ton capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in replacement of harmatically sealed Compressor (Sealed Unit) of water cooler 40/80 ltr capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard.
All as per item No. 35 above but compressor of water cooler of capacity 150 /200 ltrs.
S&F in replacement of harmatically sealed Compressor (Sealed Unit) of refrigerator 286/ 300/ 310 ltr capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foundation as required to suit the compressor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard.
All as per item No. 37 above but compressor of refrigerator of capacity 165/175 ltrs.
S & F in repairs PCB Senser of split AC indoor unit of Capacity 1.5/2 TR suitable for Videocon,Hitachi, LG, Voltas, Samsung, removing old PCB sensor and refix with new PCB of same make & capacity and model in the same position complete all as directed by Engr in Charge.
S&F pencil cell suitable of cordless type remote all as specified and directed.
S & F in repair split AC indoor unit of Capacity 1.5 TR suitable for Hitachi, LG, Voltas, including removal of old indoor unit to E/M store yard complete all as directed by Engr in Charge.
S & F in repair split AC indoor unit of Capacity 2.0 TR suitable for Hitachi, LG, Voltas, including removal of old indoor unit to E/M store yard complete all as directed by Engr in Charge.
S & F in repair split AC outdoor unit of Capacity 1.5 TR suitable for Hitachi, LG, Voltas, including removal of old indoor unit to E/M store yard complete all as specified and directed by Engr in Charge.
S & F in repair split AC outdoor unit of Capacity 2.0 TR suitable for Hitachi, LG, Voltas, including removal of old indoor unit to E/M store yard complete all as directed by Engr in Charge.
S&F in repairs condensor fan motor of water cooler of 40/80 ltr capacity of make Carrier / Voltas / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs condensor fan motor of water cooler of 60/120 ltr capacity of make Carrier / Voltas / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs condensor fan motor of water cooler 150 ltr capacity of make Carrier / Voltas / Blue star, all as directed by Engineer-in-Charge.
S&F in replacement of starting capacitor 80/100 mfd suitable for water cooler of any capacity complete all as specified and directed.
S&F in replacement of running capacitor 36/45 mfd suitable for water cooler of any capacity complete all as specified and directed.
S&F in replacement of thermostat suitable for water cooler of any capacity complete all as specified and directed.
S & F in replacement of relay with over load protector suitable for 40 to 150 ltrs capacity water cooler complete all as directed.
Labour for shifting of Split type AC indoor and out door unit of any TR capacity all as direction by Enger -in- charge
Labour for shifting of Window type AC of any TR capacity all as direction byb Enger -in- charge
Supply and fix in repair for Drain pipe for fixing to indoor unit water drain out all as directed by Enger -in- charge
M&L in replacement of refrigent pipe or tube (copper) for split type AC 1.5/2.0 TR complete all as specified directed by Enger -in- charge
S&F in replacement of copper condenser coil of outdoor unit of split type AC of 1.5 / 2.0 TR capacity complete all as directed by Engineer-in-Charge.
S&F in replacement Desert Cooler fan motor copper wound ISI marked of capacity 1/5 HP three speed, 1400 RPM single phase complete all as specified and directed.
S&F in replacement water lift submersible pump plastic body of 220-240 Volts AC Supply single phase 40 watt complete all as specified and directed.
S&F in replacement PVC elbow, PVC connection pipe dia 15mm suitable for desert cooler complete all as specified and directed
S&F in replacement 3 pin plug top of capacity 5 Amp AC 240 Volts 50 Hz complete.
S & F ply wood with commercial face of 4mm thick BWR grade for packing of AC and Desert cooler complete all as specified and directed.
S & F in replacement of plastic fan blade for fan motor of desert cooler 300 mm sweep complete all as specified and directed.
S & F in replacement of steel fan blade for fan motor of desert cooler 300 mm sweep complete all as specified and directed.
S&F in replacement of capacitor 4 MFD for fan motors of desert coolers complete all as specified and directed.
S&F in replacement side penal (shutter) made out of 22 gauge PGI Sheet with suitable hand grip,and supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers including painting to match with the existing desert cooler complete.
S&F in replacement of 15/20mm size of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed including nipple and fixing accessories complete all as specified and directed.
S&F in replacement of wood wool pad (set of three), minimum weight 0.80 Kg, fixed in side panels of desert coolers including GI wire mesh of 20 gauge wire and mesh size 100x100mm complete all as specified and directed.
S&F in replacement of 5 A switch piano type suitable for submersible pump of capacity 40Watt for desert cooler all as specified and directed.
M&L for cleaning after taking down complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparation and cleaning of surface for painting and applying two coats of synthetic enamel spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No etc complete all as specified and directed.
S & F in replacement of Bib tap made of stainless steel for water coolers as per existing make and size all as specified and directed.
Supply & fix in replacement of PVC cable flexible round 3 Core Copper conductor 4 sqmm complete all as specified and directed.
Supply & fix in replacement of PVC cable flexible round 3 Core Copper conductor 6 sqmm complete all as specified and directed.
Supply and fix in replacement of copper lugs/thimbles copper 4 sqmm complete all as specified and directed.
Supply and fix in replacement of copper lugs/thimbles copper 6 sqmm complete all as specified and directed.
S&F in replacement of PCB unit of split AC 1.5/2.0 Ton as per existing make and model complete all as specified and directed.
S&F in replacement of PCB unit of window AC 1.5/2.0 Ton as per existing make and model complete all as specified and directed.
S&F for replacement 3 pin plug top of capacity 15 Amp AC 240 Volts 50 Hz complete all as specified and directed.
Supply and fix in replacement of copper cooling coil for window AC 1.5/2.0 Ton as per existing make and model complete all as specified and directed
Supply and fix in replacement of copper condensing coil for window AC 1.5/2.0 Ton as per existing make and model complete all as specified and directed
M&L for fabricating, fixing Canopy made out of MS angle iron 40x 40 x 5 mm with GI sheet roofing of suitable size for 2 / 1.50 Ton Cap split A/C Condensor unit duly fixed on window slab/ out side external wall/ building roof of on ground with proper hold fast with PCC. Angle iron frame duly painted with two coats of black synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
National Rewinding Works
Rasam Engg Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .