Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.4 LAccepted-AOC H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹20.4 L+₹81,706 (4.18%)Rejected-Finance | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹21.7 L+₹2.2 L (11.1%)Rejected-Finance | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹21.8 L+₹2.2 L (11.4%)Rejected-Finance | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹24.3 L+₹4.7 L (24.1%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Feb 2020, 6:00 pmClosed
Lt Col Dinesh Sharma
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / MAINTENANCE OF INTERNAL ELECTRIFICATION AND EXTERNAL ELECTRIFICATION WORKS INCLUDING CERTAIN OTHER ALLIED / CONNECTED ITEMS AT BHALRA MIL STN UNDER GE (I) 873 EWS.
2020_MES_318838_1
NIT-49 of 19-20
Open Tender
Civil Works
Item Rate
180 days
Bhaderwah
Please refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE (I) 873 EWS
₹60,000
Yes
20 Mar 2020
27 Jan 2020
22 Feb 2020
27 Jan 2020
21 Feb 2020
8 Feb 2020
Amount
Taking out carefully copper / aluminium point wiring, (Light, fan, socket or power) complete with all fitting, fixtures such as switch socket out let, ceiling rose, holder, regulator, DB's etc. including making good the disturbed surface of wall/floors, complete all as specified and as directed.
Point wiring with multi stranded copper conductor of size 1.5Sqmm PVC insulated unsheathed FRLS cable in and including PVC casing and capping and accessories of suitable size for concealed wiring including 1.50 Sqmm copper earth wire (green colour) FRLS Cable for one light point or fan point or bell point controlled by one No, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including making good to disturbed surfaces of wall / floor, complete all as specified and as directed.
All as per the description of Serial Item No 02 here-in-before but for one light point controlled by two, two way switches all as specified and directed.
All as per the description of Serial Item No 02 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 02 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed.
All as per the description of Serial Item No 02 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed.
Point wiring with multi stranded copper conductor of size 1.5 Sqmm PVC FRLS insulated unsheathed cable drawn into and including PVC conduit of suitable size for concealed wiring including 1.50 Sqmm PVC FRLS copper earth wire (green colour) for one light point or fan point or bell point controlled by one, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including cutting chases and making good to disturbed surfaces of wall/floor including distempering of existing match colour complete, all as specified and directed.
All as per the description of Serial Item No 07 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 07 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed.
All as per the description of Serial Item No 07 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed.
Point wiring with multi stranded copper conductor of size 1.5 Sqmm PVC FRLS insulated unsheathed cable drawn into and including PVC conduit of suitable size for concealed wiring including 1.50 Sqmm PVC FRLS copper earth wire (green colour) for one light point or fan point or bell point controlled by one, one way switch using cable of different insulation colour for colour coding including 3mm thick laminated sheet cover, mild steel sheet or cast iron boxes including cutting chases and making good to disturbed surfaces of wall/floor including distempering of existing match colour complete, all as specified and directed.
All as per the description of Serial Item No 11 here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed.
All as per the description of Serial Item No 11 here-in-before but for one 3 pin socket outlet 5 Amp on same board, complete all as specified and as directed.
All as per the description of Serial Item No 11 here-in-before but for one 3 pin socket outlet 15 Amp independent board using cable of size 4.0 Sqm with 2.5 Sqmm copper conductor in green colour for as earth continuity conductor all as specified and directed.
Switch piano, flush type, 5 Amps, single pole, one way, complete all as specified and as directed.
Switch piano, flush type, 5 Amps, single pole, two way, complete all as specified and as directed.
Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Socket out let 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed.
Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
Bell push flush type, one way 5 Amps single pole one way all as specified and directed.
Bell / Buzzer, Ding Dong AC. 230 volts, single pole all as specified and directed.
Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings complete all as specified and as directed.
Supply only in replacement LED Lamp 230 volt 10 watts, base cap B-22, complete all as specified and as directed. Make : Havells / Crompton Greaves / Philips / Wipro
Tube light fitting box type suitable for and including LED 20 tube Rod 4' long with decorative colour in polycarbonate housing and all accessories pre-wired and making connections with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connector to light fitting complete all as specified and as directed. Make : Havells 'E-Lite LED Curve' Cat Part No LHEXBXPNIN1W020 or equivalent in Philips / Wipro / Crompton / Syska
Bulk head luminaries complete with all accessories suitable for and including 1 x 10 Watts LED lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 Volts 50 Hz complete all as specified and as directed. Make : Havells Cat Part No LHEOAOP7UZ6W010 / Crompton Cat Part No LBHE-10-CDL or equivalent in Wipro / Syska / Philips
LED recess luminaire, with high brightness SMD LEDs as light source, suitable for Armstrong / Grid ceiling, 2' x 2' size, 34 / 36 Watts including making connection from ceiling rose to fitting with PVC insulated sheathed flexible copper conductor cable of size 0.75 Sqmm complete all as specified and as directed. Make : Havells Cat Part No PLUTONEO2X2PLR34WLED857S or equivalent in Syska / Wipro / Philips / Crompton
Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 12 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed.
Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed.
Sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way including taking down and making good disturbed surfaces of walls, complete all as specified and as directed.
Isolator TPN 63 Amp 10 KA 415 Volts, complete all as specified and as directed.
Isolator TPN 40 Amp 10 KA 415 Volts, complete all as specified and as directed.
MCB SP 06 to 32 Amp 10 KA 415 Volts, complete all as specified and as directed.
MCB SPN 32 Amp 10 KA 415 Volts, complete all as specified and as directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 16 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 10 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 6 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 4 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including conduit and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 2.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Two run of 4.0 Sqmm wire, one run of 2.5 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 2.5 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including conduit and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 1.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Two run of 2.5 Sqmm wire, one run of 1.5 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
Sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 1.5 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including conduit and accessories) with continuous PVC insulated multistranded unsheathed FRLS cable earth wire of 1.5 Sqmm dia including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Two run of 1.5 Sqmm wire, one run of 1.5 Sqmm wire and one run of PVC conduit shall be considered as one unit length.
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer including taking down old unserviceable pole, complete all as specified and as directed.
Steel Tubular swaged poles type 410 SP-31 (9.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer including taking down old unserviceable pole, complete all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
Pin type insulator, porcelain, vitreous, white / brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm dia and 150mm height for working pressure 11000 volts grade, fixed in repairs, complete all as specified and as directed.
Pin type insulator porcelain, vitreous, white / brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm dia and 150mm height for working pressure 1100 volts grade, fixed in repairs, complete all as specified & directed.
Disc type insulator, porcelain, vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts, fixed in repairs, complete all as specified and as directed.
Shackle type insulator porcelain vitereous white, brown or green including galvanised M.S. straps 31 x 5mm size, 75mm height, 90mm dia including galvanised mild steel straps, nut, bolts washers complete for 1100 volts grade insulator complete including taking up of old UNSV Shakle type complete all as specified and directed.
Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 20 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, stay GI wire 7/4mm dia (loop type insulator stay clamp, excavation and concrete shall be measured and paid separately) complete all as specified and directed.
Loop type insulator, vitreous white, brown or green large size with overall dimension 90 x 140mm with clearance of hole 16mm complete all as specified and directed.
Switch air break, gang operated, triple pole, mechanically operated suitable for horizontal or vertical mounting, fixed type, mounted on insulator and steel frame with operating mechanism worked from ground level, provided with locking arrangement for operating handle, consisting of MS channel, HT post type insulator, contacts of copper alloy, high pressure, heavy duty contact assembly, operating rod of 25mm dia GI pipe medium grade, drop out expulsion assembly of phases fuses etc conforming to IS : 1018 of 1972 with continuous current rating with 15 insulators of current rating upto 400 Amps 11000 volts grade, complete all as specified & directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to atleast 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
Painting of steel tubular pole 9/11 metre long with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
Lightening arrestor, expulsion type consisting of multiple spark gaps in series with one or more non linear resister to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed direct to sun with ambient temperature below - 10 degree C to 50 degree C suitable for surge discharge capacity 65 KA, 11000 volts grade conformign to IS-4350 including all fittings, fixed in repairs, complete all as specified and as directed.
Street Light fitting 60 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Havells 'Endura Pearl Plus' Cat Part No SL60WLED757SASYTOPC or equivalent in Wipro / Philips / Crompton / Syska
MCCB 250 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 200 Amps, breaking capacity 25 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 160 Amps, breaking capacity 25 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 100 Amps, breaking capacity 25 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 63 Amps, breaking capacity 25 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed. Makes of Serial Item No '64' to '68' : L&T / Legrand / Schneider / Havells / ABB
Cable jointing kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 - 185 Sqmm including testing and commissioning including taking down old unserviceable cable jointing kit, complete all as specified & directed.
Cable jointing kit for HT 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 - 185 Sqmm including testing and commissioning including taking down old unserviceable cable jointing kit, complete all as specified & directed.
Cable jointing kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 - 300 Sqmm including testing and commissioning including taking down old unserviceable cable jointing kit, complete all as specified & directed.
Cable jointing kit for HT 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 - 95 Sqmm including testing and commissioning including taking down old unserviceable cable jointing kit, complete all as specified & directed.
Cable jointing kit for HT 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 - 95 Sqmm including testing and commissioning including taking down old unserviceable cable jointing kit, complete all as specified & directed.
M&L for disconnecting electrical connections, removing of defective 33 KV and 11 KV Vaccum Circuit Breaker (at Bhaderwah MRS) confirming to IS-13118/IEC:56 of 36KV, 1250 Amps, Three Phase, 50 Hz having breaking capacaity 25 KA, Shunt trip 110 Volts DC alongwith repair to its mechanism at site and cleaning of all contacts, bushes, terminals, spring charging mechanism, greasing of all moving parts, checking of function and physical servicibility of CT, PT, Proteion relays, Tripping system with coils, spring charging, breaker operating mechanism and reasembling of breaker complete all as specfied and as directed.
Supply only O/C E/Fault relays operating Voltage of 36 Volts.
Supply only master tripping relay operating voltage of 36 Volts
M&L for disconnecting AC distribution Panel and replacing Voltmeter, mmeter and complete wiring all as specified and as directed.
Supply only Spring Charging Motor for GEC.
Supply only Tripping and Closing Coils suitable for GEC
M&L for repairing and rewiring of 33 KV C&R Panel (Bhaderwah) MRS
Disconnecting electrical connections, removing of defective transformer, loading and transporting (up and down) to workshop from site and vice versa including disconnecting and rewinding of 11/0.433 KV 63 KVA to 250 KVA, 3 Phase, 4 wire, 50 Hz vector group DYn 11 transformer with paper insulated copper winding wire as per original data on HV (delta connection) and LV(star connection) 7 tapping brought on HV side for tap charger to change (±) 2.5%, 5%, 7.5% by means of manually operated off load tap changing gear complete rewinding of HV on three limbs providing insulation material like spares, wooden blocks, cotton tape etc and reconditioning three limbs complete ovening, replacement of cock sheet packing, vent diafram replacement of LT terminal plate, breather, filling of new transformer oil for top up with existing oil after proper filtration upto level of 45 KV at 2.5mm gap dielectric strength and testing of transformer at factory and site after connecting electrical connection in full load, complete all as specified & directed.
Notes : 1. Spares required will be measured and paid separately under appropriate item as "Supply only'. 2. The quoted rate shall deemed to include transportation, electrical connection, testing and commissioning of transformer.
Supply only Gasket suitable for 63 to 250 KVA transformer complete all as specified and as directed.
Supply only LT Terminal Plate for outgoing connections complete all as specified and as directed.
Supply only Silica Gel suitable for breather of 63 to 250 KVA distribution transformer complete all as specified and as directed.
Supply, filling and top up with new Transformer Oil of dielectric strength more than 45 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed. Make : APAR Oils / Savita
Dehydration of transformer oil by using filteration plant of suitable capacity and removing the moisture / dust till obtaining the oil dieletric strength 45 KV at 2.5mm gap and above for various transformer / voltage stablizer of any size located at different substations, complete all as specified & directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 120 Sqmm 3 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 50 Sqmm 4 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 25 Sqmm 4 core, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 11000 volts grade ISI marked cross sectional area 16 Sqmm 4 core, complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 50 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 36 x 2 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Galvanised Iron earthing strip 32 x 6 mm from earth test point to electrical equipment including taking down old unserviceable earthing strip complete all as specified and directed
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised wire of 4mm dia to connect earthpit to electrical equipment room, complete all as specified & directed.
darshan kumar gandhi
SWASTIK TRADERS
M/S Builders Indias
KUMAR CONSTRUCTION CO
M/S Chib Engineers
Neeru Contracting Company
Bidder Name
M/S BALI CONSTRUCTIONS
SWASTIK TRADERS
M/S Chib Engineers
KUMAR CONSTRUCTION CO
M/S Builders Indias
darshan kumar gandhi
Neeru Contracting Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .