Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 19 A DURGA BARI SADAR BAZAR MEERUT MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical 00 MUKUNDPUR PAHO DOMANPUR MUKUNDPUR PAHO MIRZAPUR UTTAR PRADESH 231306 | MIRZAPUR | UTTAR PRADESH | 231306 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
29 Mar 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, ETD-II, Ghaziabad
132 KV S/S Lalkuan, Ghaziabad
Works
2022_UPTCL_680558_1
T-24/ETD-II/GZB/2021-22
Open Tender
Electrical Works
Fixed-rate
60 days
132 KV S/S I.A and Govindpuram
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
As per NIT
₹2,000
Yes
4 Apr 2022
22 Mar 2022
29 Mar 2022
22 Mar 2022
29 Mar 2022
22 Mar 2022
90 days
Amount
Dismantling of defective 132 KV Breaker of ABB/CGL make of 132 KV CCIL bay after opening of 06 No. jumpers from CT and Bus islolator ,removing the earthing from breaker and disconnection of 2.5 sq. mm cable of 2,4 & 6 core of AC, DC & control units.The work also includes shifting of defective 132 KV breaker from working site to store of 132 KV Industrial Area S/S including loading and unloading at both end.
Modification of existing foundation of 132 KV CB to make suitable to circuit breaker by means of suitable galvanized angel.Work also includes cutting welding & dully suitable holes and make suitable for New CB.Angels will be provided by Department.
Erection of new 132 KV SF6 Breaker of ABB/CGL make. The work also includes modifiation and fabrication of structure by using galvanized angels and proper earthing of 132 KV breaker by using MS flat of size 50x6 mm.The work also includes carriage of breaker from store at 132 KV Industrial Area S/S to working site includes loading and unloading at both end.
Dismantling of old and used 33 KV Breaker of Alstom /Shreem/ Stell make/CGL of feeder no 40 MVA T/F I,63 MVA T/F ii after opening of 06 No. jumpers from CT and Bus islolator ,removing the earthing from breaker and disconnection of 2.5 sq. mm cable of 2,4 & 6 core of AC, DC & control units.The work also includes shifting of defective 33 KV breaker from working site to store of 132 KV Industrial Area S/S including loading and unloading at both end.
Erection of new 33 KV Breaker of Stellmake/Shreem. The work also includes modifiation and fabrication of structure by using galvanized angels and proper earthing of 33 KV breaker by using MS flat of size 50x6 mm.The work also includes carriage of breaker from store at 132 KV Industrial Area S/S to working site includes loading and unloading at both end.
Laying and Cable termination of following size i.e 2C,4C,6C & 10C cable at both ends by making cable schedule including making necessary holes in gland plates including providing of ferrules, lugs & cable tag.
Dismantling of defective 132 KV Bus/Line isolator after opening of 06 No. jumpers from Breaker and dropper from bus from 132 KV Goel gas, 63 MVA T/F I & 132 KV CCIL bay.The work also includes shifting of defective 132 KV bus/line isolator from working site to store of 132 KV Industrial Area S/S including loading and unloading at both end.
Erection of 132 KV Bus/Line Isolator Isolator as per technical specification including removing of packing and shifting to working site.
Interconnection of following associated Equpment's such as BI,/LI,Breaker etc. & with Bus-bars and BI,CT by Making Jumpers of "Panther" / "Moose" conductor of Line/ Feeder bays including cutting, bending of conductor and jumpering, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specification.
The following works are required to be carried out for providing and fixing of magnetic oil gauge in place of defective magnetic oil gauge of conservator tank of transformer intalled at 132 KV S/S Govindpuram as per details given below :- 40 MVA 132/33 Transformer-01 No
Drain out of transformer oil from conservator tank of empty transformer oil drum
Dismantling defective magnetic oil gauge of the transformer
Providing and fixing of new magnetic oil gauge in place of defective magnetic oil gauge of required size.
Top up of the transformer oil from transformer oil drum to conservator tank of the transformern with the help of pump
SATKAR TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .