Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹7.5 L
EMD Value
₹7,500
Closing Date
9 Apr 2025, 3:00 pmClosed
Commisioner Tindivanam Municipality
Tindivanam Municipality
Construction of New Physically Challenged Toilet Building at Government Hospital ward no.08 in Tindivanam municipality
2025_MAWS_536628_1
ROC.NO.513/2025/E1
Open Tender
Civil Works
Works
Tindivanam Municipality
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,500
Yes
9 Apr 2025
29 Mar 2025
9 Apr 2025
29 Mar 2025
9 Apr 2025
29 Mar 2025
Amount
Earth work excavation for foundation in all soils and sub soils and to full depth as may be required except in rock requing blasting but inclusive of shoring, strutting and bailing out water whereever necessary and refilling the sides of foundation with excavated soil other than sand in layers of not more than 15cm thick well rammed and consolidated and depositin the surplus earth with in the compound in places shown bythe departmental officers with an initial lead of 10m and lift of 2m and levelling the same etc completed complying with standard specifications and drawings.
Supplying and filling in foundation and basement with filling stone dust in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying water carrying with all leads of good water compacting and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Supply and erecting centering for sides and soffits including supports and strutting up to 3.29. High for plane surface such as RCC slabs Rectangular beams Tee (or) Ell beams lintels Bed Block, slabs, landing beam canopy side lab, or bnoxing vertical slabs, rectangular(or)sqyuare(or) coloums etc., Sheets of size with all cross branching using M.S Sheets of size 90cmx60cm and B.G 10 stidfned wih welded M,.S angle of size 25mmx25mmx3mm for boarding laid over silver oak joists of size 10cmx6.5cm, spaced at about 90cm centre to and suported by csuarnia proposal centre to centre and supoported by causarnia 10cm to 13cm dia spaced 75cm centre to centreing complete complying with standard specification. - For Grade beam allround
Supply and erecting centering for sides and soffits including supports and strutting up to 3.29. High for plane surface such as RCC slabs Rectangular beams Tee (or) Ell beams lintels Bed Block, slabs, landing beam canopy side lab, or bnoxing vertical slabs, rectangular(or)sqyuare(or) coloums etc., Sheets of size with all cross branching using M.S Sheets of size 90cmx60cm and B.G 10 stidfned wih welded M,.S angle of size 25mmx25mmx3mm for boarding laid over silver oak joists of size 10cmx6.5cm, spaced at about 90cm centre to and suported by csuarnia proposal centre to centre and supoported by causarnia 10cm to 13cm dia spaced 75cm centre to centreing complete complying with standard specification.-For column
Supply and erecting centering for sides and soffits including supports and strutting up to 3.29. High for plane surface such as RCC slabs Rectangular beams Tee (or) Ell beams lintels Bed Block, slabs, landing beam canopy side lab, or bnoxing vertical slabs, rectangular(or)sqyuare(or) coloums etc., Sheets of size with all cross branching using M.S Sheets of size 90cmx60cm and B.G 10 stidfned wih welded M,.S angle of size 25mmx25mmx3mm for boarding laid over silver oak joists of size 10cmx6.5cm, spaced at about 90cm centre to and suported by csuarnia proposal centre to centre and supoported by causarnia 10cm to 13cm dia spaced 75cm centre to centreing complete complying with standard specification. - For Lintel & slab
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requirements of IS standards. - UP to basement
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requirements of IS standards. - Above basement
Brick work in CM 1:5 (one cement & five sand) using II nd class ground moulded bricks of size 9"X4 3/8"X 2 3/4" including finishing, curing,etc., complete complying with standard specification UP to basement
Brick work in CM 1:5 (one cement & five sand) using II nd class ground moulded bricks of size 9"X4 3/8"X 2 3/4" including finishing, curing,etc., complete complying with standard specification - Above basement
Brick Partition Walls using II class ground moulded chamber bricks of size 9"X43/8"X 23/4" in C.M 1:3 using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm
Plastering with cement mortar 1:5 (one cement and five sand) 12 mm thick including cost and conveyance of all materials finishing curing and all labour charges etc., complete as per standard specification.
Special ceiling plastering and finishing the exposed surfaces of RCC works such as RCC Slabs, sunshade, facia, canopy slab, staircase, waist slab, landing slab etc., with cement mortar 1:3 (one cement and three sand) 10mm thick. Including hacking and providing necessary and as nosing, beading etc., Wherever necessary and as directed with the cement mortar etc., complete complying with standard specifications.
Painting 2 coats with approved Cement Paint over cement plastered wall surface, ceiling and other new surface and including cleaning, preparing the surface and curing etc., complete.
Dadooing walls with Glazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed.
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement
Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification
Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers.
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall Modular 5A Switch and Modular Fan Regulator with its accessories and making good of the concealed portion with suitable colour for PVC concealed light Point / Fan Point (5 Points Per Coil)
18 W LED Tubelight for T8 Fitting Single side (15- e)
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - 25mm dia
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - 32mm dia
Coupler 25 mm Dia
Coupler 32 mm Dia
Elbow 25 mm Dia
Elbow 32 mm Dia
BEND 25 mm Dia
BEND 32 mm Dia
Tee 25 mm Dia
Tee 32 mm Dia
End Cap 25 mm Dia
End Cap 32 mm Dia
Reducer 20 mm x 15 mm
Reducer 25 mm x 20 mm
Reducer Tee 20 mm x 15 mm
Reducer Tee 25 mm x 20 mm
Reducer Elbow 20 mm x 15 mm
Reducer Elbow 25 mm x 20 mm
Jet Nipple 25 mm Dia
Jet Nipple 32 mm Dia
PVC Elbow 110mm dia
PVC Elbow 90mm dia
PVC Elbow with Door 110mm dia
PVC Elbow with Door 90mm dia
PVC Tee 110mm dia
PVC Tee 90mm dia
PVC Tee with Single Door 110mm dia
PVC Tee with Single Door 90mm dia
PVC "Y" with Single Door 110mm dia
PVC "Y" with Single Door 90mm dia
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,500 litres TWAD SOR
G Ravichandran (BID ID -1287465)
stage.html
html • 0.02 MB
finance_638651.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .