| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 3 88 PASHCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | Admitted-Finance |
| 2 | Admitted-Finance F 298 GROUND FLOOR VIKASPURI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | Admitted-Finance |
| 3 | Admitted-Finance 85A 9 JWALA HERI PASCHIM VIHAR DELHI DELHI 110063 | WEST DELHI | DELHI | 110063 | Admitted-Finance |
| 4 | Admitted-Finance 8 99 GROUND FLOOR GEETA COLONY NEW DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | Admitted-Finance |
Tender Value
₹42.4 L
EMD Value
₹84,770
Closing Date
22 Dec 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (ED-1)
Works Department, AC Division, IIT Delhi, Hauz Khas, New Delhi 110016
SITC of Split and WAC Units at different places in IIT Delhi (ACCR 122 and 123)
2023_IIT_785688_1
IITD/WORKS (SP-4457)/2023
Open Tender
Miscellaneous Works
Works
60 days
Indian Institute of Technology Delhi
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹84,770
2 Jan 2024
15 Dec 2023
26 Dec 2023
15 Dec 2023
22 Dec 2023
15 Dec 2023
Amount
Supply, Installation, Testing and Commissioning of following capacity high wall split type Air Conditioner unit for cooling comprising factory built evaporator and condenser unit with remote controller with battery, as per following specifications: Star Rating: 5 Star; Compressor: Rotary type inverter inbuilt for variable speed operation; Refrigerant: Ecofriendly; Material of evaporator & Condenser : Copper; Suitable for operation on 230 volt, 50Hz, ac supply; warranty of machine: not less than 1 year; warranty of compressor: not less than 5 years. The work shall include making suitable opening in the wall / glass for drawing of refrigerant pipes, power connections to indoor and outdoor units, sealing the holes properly on the wall, mending good the damages, etc. including supplying and fixing of prototype adjustable readymade stand made of steel for resting condenser unit either on flat surface or on wall [as per site requirement - either floor mounted or wall mounted], having adequate strength for carrying load of condenser unit, duly prepainted with anticorrosive paint, nuts, bolts, fasteners, grouting / properly securing from accidental fall, fasteners, antivibration pad, etc. complete as required. (Note: cost of refrigerant pipes and power chord are not included) [Acceptable make of AC: Mitsubishi / O General / Hitachi / Panasonic / Blue Star / Carrier / Voltas / Lloyd / Daikin / LG]
Rated cooling capacity: Not less than 3500 watt
Rated cooling capacity: Not less than 5000 watt
Rated cooling capacity: Not less than 6000 watt
Supply, Installation, Testing and Commissioning of following capacity cassette type ceiling mounted split type Air Conditioner unit for cooling comprising factory built evaporator and condenser unit with remote controller with battery, as per following specifications: Star Rating: not less than 3 Star; Compressor: Rotary type inverter inbuilt for variable speed operation; Refrigerant: Ecofriendly; Material of evaporator & Condenser : Copper; Suitable for operation on 230 volt, 50Hz, ac supply; warranty of machine: not less than 1 year; warranty of compressor: not less than 5 years. The work shall include making suitable opening in the wall / glass for drawing of refrigerant pipes, power connections to indoor and outdoor units, sealing the holes properly on the wall, mending good the damages, etc. including supplying and fixing of prototype adjustable readymade stand made of steel for resting condenser unit either on flat surface or on wall [as per site requirement - either floor mounted or wall mounted], having adequate strength for carrying load of condenser unit, duly prepainted with anticorrosive paint, nuts, bolts, fasteners, grouting / properly securing from accidental fall, fasteners, antivibration pad, etc. complete as required. (Note: cost of refrigerant pipes and power chord are not included) [Acceptable make of AC: Mitsubishi / O General / Hitachi / Panasonic / Blue Star / Carrier / Voltas / Lloyd / Daikin / LG]
Rated cooling capacity: Not less than 5000 watt
Rated cooling capacity: Not less than 6000 watt
Supply, Installation, Testing and Commissioning of following capacity Window type Air Conditioner unit comprising factory built evaporator and condenser unit with remote controller with battery, in the existing window, properly sealing the gap of window with inulation, complete with electrical connections etc. anti vibrartion pad as required for installation as per following specification: Star Rating: 5 Star; Compressor: Rotary type inverter inbuilt for variable speed operation; Refrigerant: Ecofriendly; Material of evaporator & Condenser : Copper; Suitable for operation on 230 volt, 50Hz, ac supply; warranty of machine: not less than 1 year; warranty of compressor: not less than 5 years [Acceptable make of AC: Mitsubishi / O General / Hitachi / Panasonic / Blue Star / Carrier / Voltas / Lloyd / Daikin / LG]
Rated cooling capacity: Not less than 5000 watt
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft drawn copper refrigerant piping for Split AC system, complete with fittings, with suitable adjustable ring type hanger supports (wherever required), jointing / brazing including accessories, cutting of glass window wherever required with proper finishing, insulated with XPLE Class-O tubular insulation / with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. packing of all leakage either on wall or window with silicon / insulation, as required : [Acceptable make of copper pipes : Uniflow / Manibhadra / Ganpati / Mexflow / Mandev / Indigo / Godrej / Visiaro) Acceptable make of tubular insulation: Visiaro / Marshland / Avi Global / Armaflex / Aajjo / Dynamic / Uttam] NOTE: (1) The copper piping and piping circuit should be with minimum number of joints
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
GI TRAY SUPPORT: Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended / supported from the ceiling / wall with GI suspenders including GI bolts and nuts, GI C-Channels, etc. including GI protective sheet covering outside the room as required. (Only for outdoor portion)
150 mm width x 50 mm depth x 1.6 mm thickness
DRAIN PIPE: Supplying and laying of ISI marked CPVC pipe of 32 mm dia for draining of sweated water from AC evaporator (indoor) unit including providing tee, joints, elbows, supports, etc. insulated with XLPE class - O tubular insulation / woth Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick etc. complete as required.
DRAIN PIPE: Supplying and laying of ISI marked flexible braided PVC pipe of 25 mm dia for draining of sweated water from AC evaporator (indoor) unit including providing tee, joints, elbows, supports, etc. wherever required etc. complete as required.
Supplying and fixing DP sheet steel enclosure on surface / recess alongwith 5 / 10 / 16 A, 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and laying of ISI marked FRLS industrial multistranded flexible copper cable of following size of 1.1 kv grade conforming to IS694:2010 including making connection etc. for communication / indoor power supply between indoor and outdoor unit and other units, etc. through conduit complete as required. (for communication) (Acceptable make: Polycab / Havells / Gloster / RR Kabel / Nicco / Skytone / Finolex / KEI / Universal / Anchor) [NB: Single stranded cable not to be used]
4 core x 2.5 sqmm
Supplying and charging of refrigerant (R-32 / R407 / R410 / any environment friendly) as applicable for AC unit for topping up where pipe lines are lengthy etc. as required.
Supplying and fixing of 10 mm thick wooden board of suitable size for fixing of indoor unit of split AC on aluminium channel including making holes, providing screws etc. as required.
Supplying and fixing of FR PVC trunking system and accessories for covering / accommodating AC pipes, drain pipe and power chord for aesthetics in specific areas complete as directed.
(-) Less Buy-Back of Old & Outlived AC units including dismantling, removal of following type AC unit from its position including (indoor & out door, stand, pipes in case of split AC), mending good the damages, if any and buyback of the same unit etc. as directed. [as is where is basis] N.B. Bidder cannot quote below the reserve price.
2.0 TR Split AC [Reserve Price: Rs.5500 each]
1.5 TR Split AC [Reserve Price: Rs.5000 each]
1.0 TR WAC [Reserve Price: Rs.5000 each]
1.5 TR WAC [Reserve Price: Rs.5000 each]
HONEY COLLECTION
RefAir Engineering Works
TRANSCEND CONTRACTS PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .