Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC Being (L1) | |
| 2 | L2₹26.2 L+₹1.7 L (6.92%)Rejected-Finance | L2 | Rejected-Finance Other than (L1) | |
| 3 | L3₹26.3 L+₹1.8 L (7.44%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Other than (L1) | |
| 4 | L4₹28.0 L+₹3.5 L (14.4%)Rejected-Finance | L4 | Rejected-Finance Other than (L1) | |
| 5 | L5₹34.9 L+₹10.4 L (42.6%)Rejected-Finance | L5 | Rejected-Finance Other than (L1) |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE(AF) EM Chakeri, Kanpur
ERHAULING OF LIGHTEING ARRESOT SYSTEM IN TECH AREA AT AFS KANPUR
2023_MES_605716_1
8633/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (AF) E/M CHAKERI
₹60,000
Yes
30 Aug 2023
26 Jun 2023
29 Jul 2023
26 Jun 2023
24 Jul 2023
10 Jul 2023
Amount
Dismantling/taking down old unserviceable lightening conductors & material & labour for fixing lightening conductor assembly made out of GI pipe light grade of size 50 mm bore along with welded flange at one end & GI reducer socket 50 x 40mm at another end connected with GI pipe light grade of size 40 mm bore with one end GI reducer socket to connect air termination & connector for earth strip duly fixed with necessary nuts bolts & washers in PCC 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) 30cm x 30cm x30cm complete all as specified and directed. Note: GI pipe 40/50mm & air temination shall be measured & paid separately under relevant items.
Supply only GI pipe light grade (ISI marked) of size 40 mm bore for erection of lightening conductor as required complete all as specified and directed.
Supply only GI pipe light grade (ISI marked) of size 50 mm bore for erection of lightening conductor as required complete all as specified and directed.
Supply only air termination Aluminium rod 12mm dia, 300 mm long for lightening conductor complete all as specified and directed.
Supply only air termination Aluminium rod 10mm dia, 900 mm long for lightening conductor complete all as specified and directed.
S&F aluminium strip 25 x 3.15 mm on wall/batten or recessed or buried in ground complete all as specified and directed.
S&F copper strip 32 x 6 mm on wall/batten or recessed or buried in ground complete all as specified and directed.
S&F copper strip 20 x 3 mm on wall/batten or recessed or buried in ground complete all as specified and directed.
S&F GI strip 32x6mm on wall/batten or recessed or buried in ground complete all as specified and directed.
S&F in replacement porcelain insulator of required size not exceeding 10 cm long with two nos hole each on both end for fixing properly with nuts & bolts on wall of buildings for separated to lightining conductor or earthing stirp from building all as required at site complete all as specified and directed. Note : The distance between two insulators fixed on the wall not more than 1.00m length.
S&F epoxy insulators 25mm dia base with suitable screws, washers, necessary bituminious water proof materials for leakage proof joint complete for alumnium strip size 25x3.15mm all as specified and directed by Engineer in Charge.(Note: Rate quoted by the contractor deemed to be inclusive of necessary repair work for water proofing if ccurs while fixing insulators over roof top of building).
M&L for testing of old earthing using calibrated earth tester & submitting result to the Engr -in -Charge. Earthing which showing highe results valueas specified in IS rule and disconnetivity should be replaced with new earthing items are considered as below complete all as specified and directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
M&L for making High conductive, Non corrosive, Maintenance Free yet Repairable Electro-Chemical - Gel earth pit suitable for Lightning Conductor application using earth enhancing compound ISOGEL of 20 kg kit, CPRI Tested 'ISOROD' of 3 inch dia, 8 ft long and 0.12 inch thick made of K type electrolytic copper with top removal gel filling cap, seepage holes, Stainless steel fasteners, HDP Lockable earht pit cover cum inspection/termination chamber and all required accessories including design modifications, to achieve the required earth termination rod resistance value of less then 1 ohms complete all as specified and directed. Note:- 1. Cost of earth work complete is included in the unit quoted rate. 2. Cost of strip 32x6 mm copper up to 7.50m and connecting to equipement is included in the unit quoted rate. 3. Test point to be made on insulation base i.e. porcelain insulator or mica sheet of 3 mm thick and the same is included in the unit quoted rate. If earth resistance value is found to be outside the permissible limits successful bidder shall do fresh earthing on his own expense.
M&L (in replacement) for MS plate size 0.05 sqm of triangle /rectangular shape and oval shape to identify the earthing not less than 1.6 mm thick and angle/ strip iron 25x3 mm and 600mm height welded with plate and grouting vertically alongwith earthing pit with PCC block not less than 300mm x 300mm x 300 mm duly painted background with black colour and writing arial font with white colour the type of earthing i.e. Chemical earthing No.X /Copper earthing No.XX /Charcoal earthing No. XXX and Earthing Result in Ohm and date of testing,date of due date of testing complete all as specified and directed.
M&L (in replacement) for earthing complete with MS galvanized earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal GL) with top edge of the earth plate not less than 1.50 m below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel including excavation, earth work, returning filing, removal of extra soil, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) chamber with RCC cover (1:2:4) type B0 (using 12.50 mm graded crushed stone aggregate) 40 mm thick reinforced with 8 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe upto 7.5 m, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.50 m including charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and directed. Note : Cost of earth lead wire upto 7.50m and GI pipe for protection of earth lead wire are deemed to be included in the quoted rate.
M&L (in replacement) for earthing complete for building with copper plate of size 600mm x 600mm x 3.0 mm with copper earth strip of size 25 x 3 mm and earth pit not less than 4.25 m deep below normal ground level with top edge earth of the plate not less than 3.50 m below normal ground level connected to copper strip (25mm x 3 mm ) from earth plate to test point by means of brass bolts, nuts, check nuts and lead washers or copper riveted joint including excavation, earth work, returning filing, removal of extra soil, char coal dust, common salt, funnel with wire-mesh, 20 mm dia light grade GI pipe for watering and 40 mm dia GI pipe light grade for protection pipe upto 7.50 m for copper strip and PCC pit 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) and RCC cover of 40 mm thick with 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) reinforced with 6 mm dia mild steel round bar 75 mm C/C both way with two Nos 12 mm dia MS handle complete all as shown in electrical plate No 3 of SSR Part I including testing complete all as specified and directed. Note : Cost of copper earth strip upto 7.50m and GI pipe for protection of copper earth strip are deemed to be included in the quoted rate.
M&L (in replacement) for earthing complete with MS galvanized earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal GL) with top edge of the plate not less than 1.50m below normal GL, connected to galvanized earth strip 32mm x 6mm upto 7.50 m with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel including excavation, earth work, returning filing, removal of extra soil, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) chamber with RCC cover (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe upto 7.50 m , funnel with wire mesh, watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.50m including Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification complete all as specified and directed. Note : Cost of GI earth strip upto 7.50m and GI pipe for protection of GI earth strip are deemed to be included in the quoted rate.
M&L (in replacement) for earthing complete with copper plate electrode 90cm x 60cm x 5 mm thick buried directly in ground with top edge of plate not less than 4.5mtr deep below the normal ground level connected to copper strip 32mm x 6mm as main earthing lead and connected and tinted copper bolt, nuts, check nuts and washers besides braising at all joints all as directed and connected to earth test point all as specified and directed on completion with and including necessary excavation, earth work, returning filing, removal of extra soil etc, filing adequate qty of charcoal dust, common salt and MgSO4, PCC work (1:3:6) type C1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40mm x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) 40mm thick cover reinforcement with 8mm TMT bar @ 75 C/C on both way with funnel with wire mesh and 50mm dia GI light grade for earth lead protection pipe and 40 mm dia GI medium grade for watering complete all as specified and directed.
M&L (in replacement) for earthing complete with MS galvanized earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal GL) with top edge of the plate not less than 1.50m below normal GL, connected to galvanized earth strip 25mm x 4mm upto 7.50 m with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel including excavation, earth work, returning filing, removal of extra soil, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) chamber with RCC cover (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe upto 7.50 m , funnel with wire mesh, watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.50m including Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification complete all as specified and directed. Note for item No 15 to 19 :- (i) The excess requirement (if more than 7.5 Mtr) of GI/Aluminium/copper strip and their joints for connecting upto the test point and GI pipe will be measured and paid separately) (ii) The excavation exceeds if any is deemed to be included in the quoted rate.
S&F in replacement GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
M&L for cutting/boring of PCC / WBM / hard standing at a depth not more than 30 cm deep & 20 cm in breath and making good disturbed surfaces by using the new materials as directed on cutting areas/ disturbed surfaces complete all as speified and directed
Dismantling / taking down old rusted copper / GI / Al strip from any height or situation complete all as specified and directed.
M&L (in replacement) for broken earthing pits chamber with PCC (1:3:6) type C-1 with RCC cover (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate), 40 mm thick, reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipe including painting with synthetic enameled white colour paint with mixing of colour (Red/Green/Yellow) of earthing pits of diffirent colour as per Earthing type (Chemical/Lightening Protection and Conventional) complete all as specified and directed.
M&L for Test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed on wall including three nos 8mm dia 25mm long hexagonal head screwes complete all as directed by Engineer in Charge.
M&L (in replacement) for broken lightening arrestor PCC by providing new PCC grouting Plastic gulli on room and flange to be fixed with screw after dismentling complete PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) of size 150mm x 600mm x 600mm and above 150mm x 300mm x 300mm and rendering in cm 1:4 finished even and fair complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregeate as in pole coping etc. all as directed by Engineer in Charge.
S&F in replacement of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site complete all as specified and directed.
M&L for painting externally of earthing pit with two synthetic enameled paint of white colour and mixing of colour (Red/Green/Yellow) of earthing pits of diffirent colour as per earthing type (Chemical/Lightening Protection and Conventional ) complete all as specified and directed.
PAWAN COOL CORPORATION
santosh electronics
M/s Sohanil Construction
Manoj Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .