Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 6 VISHNU SHREYA COMPLEX PLOT NO 87 87 A SECTOR 50 E OFF PALM BEACH ROAD SEAWOODS NERUL WEST NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | Admitted-Finance |
| 3 | Admitted-Finance SABARIGIRI TC 21 2500 JUDGE ROAD KARAMANA TRIVANDRUM 695002 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695002 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
4 Aug 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM Engg. Scope Complex
GM Engg Scope complex ,Core 8,Lodhi Road ,New Delhi
Construction of Meditation / Yoga Center, Community Kitchen, Entrance Gate, Public Convenience and View Deck Point and Resting of building at Arruvipuram Temple, Kerala
2021_ITDC_82459_1
ITDC/Engg/Aruvipuram/2021
Open Tender
Construction Works
Works
365 days
ITDC, Engg. Div New Delhi
please refers per NIT
16 documents required · 16 mandatory
₹0
Exempted
23 Oct 2021
19 Jul 2021
5 Aug 2021
19 Jul 2021
4 Aug 2021
19 Jul 2021
90 days
Amount
Part-A (Community Kitchen)(Civil Works) Demolishing and Dismantling works Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : in cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area 3 sq. metres and below
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: in cement mortar
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling roofing including ridges, hips, valleys and gutters etc, and stacking the material within 50 metres lead of: Asbestos cement sheet
Disposal of building rubbish / malba similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engr.-in-Charge beyond 50 m initial lead, for all loads including all lifts involved.
Earth work excavation + Filling & Surface dressing Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Concrete Works Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size .
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers & cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Suspended floors, roofs, landings, shade balconies and access platform with water proof ply 12 mm thick
Edges of slabs and breaks in floors and walls Under 20 cm wide
Reinforcement work Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1Cement: 1½ coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
PLASTERING Ceiling plastering 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Inside & outside plastering 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
JOINERY Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood. 35 mm thick
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood. 35 mm thick
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x70x4mm (ordinary type)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100 x 70 x 4mm (ordinary type)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete: 250x10 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete: 150 x10 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete : 250 mm weighing not less than 280 gms
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete
Providing and fixing bright finished brass hard drawn hooks and eye 250 mm with necessary screws, etc. complete.
GRILL Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Flooring Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) :25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and pre-polished machine cut for kitchen platforms, Vanity Counters, window sills facias and similar locations of required size, approved shade colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy tough ups, including rubbing, curing moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colours and shade. Area of slab over .5sqm
French Sprit Polishing Two or more coats on new works including a coat of wood filler
Painting Providing and applying white cement based putty of average thickness 1mm,of approved brand & manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Wall panting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two or more coats on new work.
Painting with oil type wood preservative of approved brand and manufacture: New work (two or more coats)
Melamine polishing on wood work (one or more coat).
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Mangalore tiles Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on RCC slab / reapers with 20 mm thick average cement mortars 1:4 (1 Cement : Coarse Sand).
Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on RCC slab with 20 mm thick average cement mortar 1:4 (1 Cement : 4 Coarse Sand).
Water proofing Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Anti-termite treatment Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for Post constructional anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos / Lindane E.C. 20% with 1% concentration
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
Plumbing works Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Kitchen Sink without drain board 610x510 mm bowl depth 200 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (a) 15 mm nominal outer dia Pipes
(b)20 mm nominal outer dia Pipes
(c)25 mm nominal outer dia Pipes
(d)32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement,trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (a) 20 mm nominal inner dia Pipes
b) 25 mm nominal inner dia Pipes
c) 32 mm nominal inner dia Pipes
d) 40 mm nominal inner dia Pipes
e) 75 mm nominal inner dia Pipes
f) 100 mm nominal inner dia Pipes
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5
Soakpit for waste water harvesting - Digging well of inner dia 90cm and depth 3m , supplying and erecting 90cm ring solling with 40mm metal and brick jelly for full depth, covering with 15mm thick RCC cover slab etc., including cost and conveyance of all materials like steel shuttering and all labour charges etc. complete.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Part B - Meditation and Yoga Centre (Civil Works) Earth works excavation Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (blasting prohibited)
Providing and Inserting 16mm dia Anchor bar in to the hard rock up to a depth of 45cm on both ways, etc. complete as per directions of Engr.-in-Charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Surface dressing Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Concrete Works Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size.
Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete
b) Lintels, beams, plinth beams, girders, bressumers and cantilevers
c ) Walls (any thickness) including attached pilasters, butteresses, Plinth and string courses etc.
d) Columns, Pillars, Piers, Abutments, Posts and Struts
e) Suspended floors, roofs, landings, shade balconies and access platform with water proof ply 12 mm thick
f) Edges of slabs and breaks in floors and walls Under 20 cm wide
g) Stairs, (excluding landings) except spiral-staircases
Reinforcement work Steel reinforcement for R. C. C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete: 1:1½:3 (1 cement: 1½ coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
PLASTERING Ceiling plastering 6 mm cement plaster of mix: 1:3 (1 cement : 3 fine sand)
Inside & Outside walls plastering 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In two coats
JOINERY Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood. 35 mm thick
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete. 125x70x4 mm (ordinary type)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete
Grill Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/wooden frames with rawl plugs screws etc.
FLOORING Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Agaria white
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge for side steps Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite Work Wall cladding up to beam height Providing and fixing 1st quality Laterite Stone wall cladding tiles of design, size & colour as approved by Engr.-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete.
PAINTING Providing and applying white cement based putty of average thickness 1mm,of approved brand & manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand & manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats
Painting with oil type wood preservative of approved brand and manufacture : New work (two or more coats)
Melamine polishing on wood work (one or more coat).
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Clear coat painting on tile / stone wall cladding area with 2 clear coats of paint approved by the Engineer-in-Charge, including applying additional coats of paint wherever required, to achieve even shade complete including colour, cost and conveyance of all materials and labour charges etc.
Mangalore pattern tiles Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern , Laying tiles on mild steel L angle section of size 25x25x3mm over RCC slab. The L angle shall be fixed using screws, and painting the L angle using 2 coat epoxy paint over epoxy primer etc. complete.
Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on RCC slab with 20 mm thick overage Cement Mortar 1:4 (1 Cement : 4 Coarse Sand).
Water proofing Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns).The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Paving Granite tile Providing and laying 60x60x5 cm Granite stone block hand cut and chisel dressed on top, for paving in pathway , laid over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge
SS Handrail Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Anti-termite treatment Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for Post constructional antitermite treatment (excluding the cost of chemical emulsion): Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
Folding partition Supply and installation of manually operated acoustic folding and sliding partition wall (folding in double side side) for ground floor with laminate and fabric panel finish on both sides, Panel thickness of 75mm thick with 45dB sound rating, having Panel width of 100cm and panel height of 3 meter . standard exposed aluminium trims and centre stacking, tracks and accessories, top and bottom retractable panels(with laminate/foam back fabric finish). Including all structural members, all charges, cost and conveyance of all materials and labour charges etc. complete as per directions of Engineer-in-charge
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long drywall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete 75mm overall thickness partition with 12.5 mm thick double skin tapered edge plain Gypsum plaster board conforming to IS: 2095: (part I) 2011 (Board with BIS Certification marks.
Supplying and providing a layer of resin bonded glass wool of density 32 Kg / m3 inside between the above gypsum partition panels during fixing the panels in position by tying G.I wire etc. as per instructions and directions of Engr.-in-Charge
Providing and fixing 2nd class teak wood plain lining tonged and grooved including wooden plugs complete with necessary screws and priming coat on unexposed surface. 25mm thick.
Providing and fixing specified wood frame work considting of batterns 50x25mm fixed with rawl plug and drilling necessary holes for rawl plug etc including priming coat complete. Kiln seasoned and chemically treated hollock wood
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Curved surfaces.
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: Pink plain marble
Part C - Entrance Gate (Civil works) :- Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. All kinds of soil .
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40mm nominal size).
Supplying and fixing entrance gate made of Krishna Shila Single stone with ornamental works as per drawing, Height of 6.52 Mtr, Base width is 68cm and Middle width is 56cm and top width of 77cm and design as per the detailed drawing, fixing the pillar with plain cement concrete (PCC will be paid separately) complete as per the instruction of Engineer-in-Charge.
Clear coat Painting on Krishna Shila pillar with 2 coats clear coat of Indigo paint of brand approved by Engr.-in-Charge, including applying additional coats wherever required, to achieve even shade and colour, cost and conveyance of all materials and labour charges etc. complete.
Public Conveniences - 2 Nos (Civil Works) Earth work excavation + Filing & Surface dressing Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m. All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (Blasting prohibited)
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50m and lift upto 1.5m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc complete
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
Concrete Works & Solid Block Work Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:- 1:4:8 (1 Cemen 4 coarse sand (zone-III) : 8 graded stone aggregate 40mm nominal size) for foundation
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement:1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Centering and shuttering including strutting, propping etc. and removal of form for (a) Lintels, beams,plinth beams, girders, bressumers and cantilevers
(b) Suspended floors, roofs, landings, shade balconies and access platform. with water proof ply 12 mm thick
Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
PLASTERING :- 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Inside & Outside walls plastering 12mm cement plaster of Mix: 1:4 (1 cement: 4 coarse sand)
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
JOINERY Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately. Second class teak wood 35 mm thick
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood 35 mm thick
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x70x4 mm (ordinary type) .
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm (ordinary type) .
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150 x10 mm.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete :250 mm weighing not less than 280 gms
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete
Providing and fixing bright finished brass hard drawn hooks and eye 250with necessary screws, etc. complete.
GRILL:- Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings /wooden frames with rawl plugs screws etc
FLOORING :- Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Providing and laying rectified glazed cermaic or more floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigment etc., complete .
Providing and fixing Ist quality ceramic glazed wall tiles of conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete .
Wall cladding:- Providing and fixing 1st quality Laterite Stone wall cladding tiles of design, size & colour as approved by Engr.-in-Charge, in skirting risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete.
PAINTING Providing and applying white cement based putty of average thickness 1mm,of approved brand & manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats
Painting with oil type wood preservative of approved brand and manufacture : New work (two or more coats)
Melamine polishing on wood work (one or more coat).
Clear coat Painting on tiles/stone wall cladding area with 2 coats of paint approved by the engineer incharge, including applying additional coats of paint wherever required, to achieve even shade and colour, cost conveyance of all materials and labour charges etc . Two Coats
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work.
Structural Steel Work Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Mangalore pattern tiles on steel frame Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately)
Anti termite treatmant Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for Post constructional antitermite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 m m including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
PLUMBING WORKS Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete
Supplying and fixing Under counter Oval shape 560X470mm or nearest size wash hand basin of white glazed earthenware (Indian make best quality) counter sunk of basic rate of Rs. 900.00/each including supplying and fixing brass waste coupling, pillar tap (Heavy, best quality) 1 no., 32mm PVC waste pipe and 15mm heavy duty PVC connection - 1 no 15mm CP Brass angle valve -1 no including cutting and making good the walls etc. complete as direction of engineer- in-charge.
Supplying and fixing CP brash health faucet with the 8mm dia,1.2 m long flexible tube and wall hook as per directions of Engineer in charge.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore,80 mm long,42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing squaremouth S.W.gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I.cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
Supplying and fixing multi floor trap with jalli 110 mm dai including cost of cutting and making good floors & walls.
Providing and fixing PTMT grating of approved quality and colour Rectangular type with openable circular lid
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (a) 25 mm nominal bore
(b) 20 mm nominal bore
(c )32 mm nominal bore.
(d) 40 mm nominal bore.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (a) 20 mm nominal outer dia Pipes
(b)25 mm nominal outer dia Pipes
(c)32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (a) 20 mm nominal inner dia Pipes
(b) 25 mm nominal inner dia Pipes
(c ) 32 mm nominal inner dia Pipes
(d) 40 mm nominal inner dia Pipes
(e)75 mm nominal inner dia Pipes
(f) 100 mm nominal inner dia Pipes
Constructing masonry Chamber 30x30x50 cm inside in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 Mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal Size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Soakpit for waste water harvesting - Digging well of inner dia 90 cm and depth 3 m , supplying and erecting 90 cm ring , solling with 40 mm metal and brick jelly for full depth , covering with 15 mm thick rcc cover slab etc , including cost and conveyance of all materials and all labour charges etc complete.
Septic tank Constructing RCC septic tank of capacity 10500 Ltrs inner size 3.44m x 1.94m x 1.54m with RCC cover slab including earthwork in excavation PCC 1:5:10 15 cm thick for foundation , 150 mm thick sand filling, Reinforced cement concrete 1:1.5:3 for base slab of thick 23 cm & cover slab 15 cm thick , Brick wall of thick 20cm in cement mortar 1:4 , inner wall plasteing with cement mortar 1:3, 12 mm thick finished with a floating coat of neat cement complete as per standard design/drawing including cost and conveyance of all materials and labour charges etc.and directions of engineer in charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
VIEWING DECK (Civil Works) Earth work Excavation + Filling & Surface dressing Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (Blasting prohibited)
Inserting 16mm dia Anchor bar in to the hard rock up to a depth of 45cm on both ways etc. Complete as per direction of engineer in charge.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50m and lift upto 1.5m.
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
Concrete Works & solid block work Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) 8 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Centering and shuttering including strutting, propping etc. and removal of form (a) Foundations,footings, bases of columns etc. for mass concrete
(b)Lintels, beams, plinth beams, girders, bressumers and cantilevers
(c)Columns, Pillars, Piers, Abutments, Posts and Struts
Suspended floors, roofs, landings, shade balconies and access platform. with water proof ply 12 mm thick
Edges of slabs and breaks in floors and walls under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete: 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) .
PLASTERING :- Inside & Outside walls plastering 12mm cement plaster of Mix:- 1:4 (1 cement: 4 course sand)
FLOORING Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand): 25 mm thick
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
PAINTING Providing and applying white cement based putty of average thickness 1mm,of approved brand & manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Resting building (Civil Works) (Earth work excavation + Filling & surface dressing) Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth,1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard rock (Blasting prohibited)
Insereting 16mm dia Anchor bar in to the hard rock up to a depth of 45cm on both ways etc. Complete as per direction of engg-in-charge.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50m and lift upto 1.5m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc complete
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead up to 50m and lift up to1.5m. All kinds of soil
Retaining wall :- Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand
Concrete Works & solid block work Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement: 4 coarse sand (zone-III) 8 graded stone aggregate 40mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement:1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size
Centering and shuttering including strutting, propping etc. and removal of form for : (a) Foundations,footings, bases of columns etc. for mass concrete
(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers
(c)Columns,Pillars, Piers, Abutments, Posts and Struts
(d) Suspended floors, roofs, landings, shade balconies and access platform. with water proof ply 12 mm thick
Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete: 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) . For 20 cm & 10 cm thick
PLASTERING 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) Ceiling plastering
Inside & Outside walls plastering 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In two coats
JOINERY Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately :- Second class teak wood :- 35 mm thick
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws :- Second class teak wood :- 35 mm thick
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand:6 graded stone aggregate 20mm nominal size).
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x70x4 mm (ordinary type)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 100x70x4 mm (ordinary type)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150 x10 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete
Providing and fixing bright finished brass casement stays (straight peg type) with necessary screws etc. complete: 250 mm weighing not less than 280 gms
Providing and fixing bright finished brass hanging type floor door stoper with necessary screws, etc. Complete
Providing and fixing bright finished brass hard drawn hooks and eye 250 mm with necessary screws, etc. complete.
GRILL :- Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc
FLOORING Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand): - 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge:- Granite work
Wall Cladding Supplying and fixing cladding tiles ( Laterite) on front walls of the building with cement mortar 1:4 over the plastered surface area, including cost and conveyance of all materials and labour charges etc complete.
PAINTING Providing and applying white cement based putty of average thickness 1mm,of approved brand & manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour :- Two coats
Painting with oil type wood preservative of approved brand and manufacture : New work (two or more coats)
Melamine polishing on wood work (one or more coat).
Clear coat Painting on tile/stone wall caldding area with 2 clear coats of paint approved by engg-in-iharge, including applying additional coats of paints wherever required, to achieve even shade complete including colors cost and conveyance of all materials and labour charges etc
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
Water proofing Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns).The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Anti termite treatmant Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for Post constructional antitermite treatment (excluding the cost of chemical emulsion): Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 m m including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
Mangalore pattern tiles on RCC work Providing & fixing on roof pressed clay tile (Mangalore tile) of 20mm nominal thickness and of approved size and as per approved pattern on reapers over the RCC slab work with 20 mm thick average cement mortor 1:4 ( 1 Cement : 4 Course Sand)
Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on RCC slab slab work with 20 mm thick average cement mortor 1:4 (1 Cement : 4 Course Sand)
PLUMBING WORKS Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing squaremouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I.cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
Supplying and fixing multi floor trap with jali 110 mm dia including cost of cutting and making good floors & walls.
Providing and fixing PTMT grating of approved quality and colour:- Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (a) 25 mm nominal bore
(b) 32 mm nominal bore.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge:- Concealed work, including cutting chases and making good the walls etc. (a) 20 mm nominal outer dia Pipes
(b) 25 mm nominal outer dia Pipes
(c)32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer -in -Charge. External work :- (a) 20 mm nominal inner dia Pipes
(b) 25 mm nominal inner dia Pipes
(c )32 mm nominal inner dia Pipes
(d) 40 mm nominal inner dia Pipes
(e) 75 mm nominal inner dia Pipes
(f) 100 mm nominal inner dia Pipes
Constructing masonry Chamber 30 x 30 x 50cm inside in brick work in cement mortar 1:4 (1cement :4 coarse sand) for stop cock,with C.I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation,foundation concrete 1:5:10 (1cement :5 fine sand :10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1cement :3coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design:- With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
P&F 18 mm thick gang saw cut mirror polished, premoulded and prepolished, machine cut for kitchen platfors, vanity cements, window sill, facias and similar locations of required size approved shade colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) , joint treated with white cement, mixed with matching pigmant epoxy touch ups, including rubbing, curing moulding and polishing to edges to give high gloes finish etc. complete at all levels, granite of any colour and shade. Area of slab over 0.50 sqm.
ELECTRICAL ESTIMATE FOR ARUVIPURAM TEMPLE ARUVIPURAM (COMMUNITY KITCHEN) (INTERNAL ELECTRICAL INTSTALLTIONS & WIRING) Point wiring in PVC conduit with modular type switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Twin control point wiring in PVC conduit ,with modular type switch: Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group control point wiring in PVC conduit : Wiring for group controlled (looped) light point/fan point/exhaustfan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium class pvc conduit conduit as required.
2 x 1.5sq.mm + 1 x 1.5 sq.mm earth wire
2 X 2.5 sq.mm + 1 X 2.5sq.mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing type 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch, connection, painting etc.as required. (For raw power outlets)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6amps modular socket outlet (3 module type) and 15/16 amps modular switch, connection, painting etc.as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Supplying and fixing 20 Amps, 240 Volts, SPN industrial type, Socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps, 2 Pole, RCCB in sheet steel enclosure , on surface or in recess with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. a) 25A, 3 pin socket outlet controlled by 20A 2P RCCB
Supplying and fixing of following sizes of medium gauge PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
SF SP/TP MCB DB's & VDB's Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (space for incomer RCCB + Isolator+ 12), Double door
6 way (space for incomer RCCB + Isolator+ 18), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
4 way (space for incomer RCCB + Isolator+ 18), Double door
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6- 32A Single pole
6- 32A Triple pole
40 Amps Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in sheet steel enclosure, on surface or in recess, with chained cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply and installation of DIN Rail Surge Protection Device (4+0) in suitable enclosure Class B + Class C/ Type 1 + Class 2 Tested as per IEC 61643 Part 11:2016. Nominal voltage -230V 50/60Hz, MCOV of 275 V , Total Impulse current-50 KA (10/350~ sec) & Total Max Discharge current 260KA (8/20~sec), Voltage protection level <1.5 kV & Residual Voltage @5 kA(8/20) <0.8kV. The Surge Protection Devices should have TOV safefail for 120 Min : 442 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for: L & N to PE. Short- Circuit Current rating (Isccr) - 50 kA/50 Hz . Back up fuse required more than 315AgG/ gL. Health Status Indication required in all cartridge. Total Response time <25 nano sec. (VDB INCOMER)
SUPPLY AND INSTALLATION OF INTERNAL LIGHT FITTINGS AND FANS INTERNAL LIGHT FITTINGS AND FANS Supply, installation, testing and commissioning of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.
SITC of LED 18 Watt Reccessed/ surface mounted LED matte white downlighter housing made of elluminum with height translucent diffusre with colour tempetrature of 5700/6500 K.
SITC of sleek and seamless profiled extruded aluminium/ Polycarbonate batten with efficent diffuser to enlighten workspaces and retial spaces and built in electronic driver 1 X 20 Watt LED Tube Light
SITC of 450 mm ( 18") sweep swing hi speed wall mounted Fans complete with all fittings or as approved make
SITC of heavy duty exhaust fans of following size sweep with gravity louvers shutters including all accessories/ installation materials required 300 mm sweep 900 rpm
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
CABLES 4 CORES AL. CONDUCTOR. 25 sq.mm. Al. Armoured XLPE insulated cable
4 CORES AL. CONDUCTOR 16 sq.mm. Al Armoured XLPE insulated cable
4 CORES AL. CONDUCTOR.10 sq.mm. Al. Armoured XLPE insulated cable
3 CORES AL. CONDUCTOR 10 sq.mm. Al Armoured XLPE insulated cable
(CABLE LAYING) Laying and fixing of one number PVC/XLPE insulated and PVC sheathed armoured power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2/3/3.5/4 CORES AL. CABLE WITH AL. LUGS
3C X 10 sq. mm (22mm)
4C X 10 sq. mm (25mm)
4C X 16 sq. mm (28 mm)
4C X 25 sq. mm (28 mm)
Earthing PIPE ELECTRODE EARTHING STATIONS Earthing with G.I. earth pipe 4.5 meter long,40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/cock and salt as required.
Earthing Conductors: Supplying, straightening, shaping, laying under ground / laying on a cable tray / laying in cement concrete trench the following sizes of copper/hot dipped galvanized iron conductor. The work is inclusive of providing clamping with the trays / on the sides of the trenches, making joints whereever required and providing the hardwares and the terminating the hardwares and the termination to the equipment / earthing station / etc.
Copper Conductors: 06 SWG
Electrical Work Construction of Yoga & Meditation Building (INTERNAL ELECTRICAL INTSTALLATIONS & WIRING) Point wiring in PVC conduit with modular type switch.:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group- C
Twin control point wiring in PVC conduit ,with modular type switch: Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group control point wiring in PVC conduit : Wiring for group controlled (looped) light point/fan point/exhaustfan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium class pvc conduit conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing type 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch, connection, painting etc.as required. (For raw power outlets)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6amps modular socket outlet (3 module type) and 15/16 amps modular switch, connection, painting etc.as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Supply,fixing and wiring of 25 A modular switch socket grade PVC conduit concealed in ceiling,or floor,or wall,or column including fixing of 20 A DP modular switch and covered with modular switch plate interconnections, supply of fixing materials, complete as required.
Supplying and fixing of following sizes of medium gauge PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
SF SP/TP MCB DB's & VDB's : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door (ups db)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (space for incomer RCCB + Isolator+ 12), Double door
6 way (space for incomer RCCB + Isolator+ 18), Double Door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.
4 way (space for incomer RCCB + Isolator+ 18), Double Door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 250 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required.
8 way (space for incomer MCCB + 24), Double Door
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6- 32A Single pole
6-32A Triple pole
40Amps/63A triple pole
DPX3 MCCB with thermal magnetic protection unit 125A 25kA 4P
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in sheet steel enclosure, on surface or in recess, with chained cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth (3P+N+E), metal enclosed plug top alongwith 25 A "C" curve, TPN MCB, in sheet steel enclosure, on surface or in recess, with chained cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply and installation of DIN Rail Surge Protection Device (4+0) in suitable enclosure Class B + Class C/ Type 1 + Class 2 Tested as per IEC 61643 Part 11:2016. Nominal voltage -230V 50/60Hz, MCOV of 275 V , Total Impulse current-50 KA (10/350~ sec) & Total Max Discharge current 260KA (8/20~sec), Voltage protection level <1.5 kV & Residual Voltage @5 kA(8/20) <0.8kV. The Surge Protection Devices should have TOV safefail for 120 Min : 442 V and with out Follow Current & Leakage Current. Protective Elements are High Energy MOV & GDT & the Protection Modes for: L & N to PE. Short- Circuit Current rating (Isccr) - 50 kA/50 Hz . Back up fuse required more than 315AgG/ gL. Health Status Indication required in all cartridge. Total Response time <25 nano sec.(VDB INCOMER)
Supply and Installation of Internal Light Fittings Internal Light Fitting and Fans: Supply, installation, testing and commissioning of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall (All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.
12 W down light Recess (Cafeteria,lobby& rooms)
12 W down light Surface (Stair)
4 FT LED Batten
6 W down light Recess (Toilet)
LED batten Conduit suspension mounted LED batten, 4ft.
Supplying Installation,testing & commissioning of 1200mm sweep (White) 5 star rated ceiling fan without regulator including wiring the down rod of std.length ( upto 30cms) with 1.5 Sqmm PVC insulated copper conductor, single core cable etc as required.
Supplying Installation,testing & commissioning of 100mm sweep (White) ceiling Exhaust fan
Cables 4 Core AL. Conductor 25 sq.mm. Al. Armoured XLPE insulated cable
4 Core AL. Conducto 16 sq.mm. AL. Armoured XLPE insulated cable
4 Core AL. Conducto 10 sq.mm. Al. Armoured XLPE insulated cable
3.5 Core AL. Conductor 50 sq.mm. Al Armoured Armoured XLPE insulated cable
3 Core AL Conductor 10 sq.mm. Al Armoured XLPE insulated cable
Laying and fixing of one number PVC/XLPE insulated and PVC sheathed armoured power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2/3/3.5/4 CORES AL. CABLE WITH AL. LUGS
3C X 10 sq. mm (22mm)
4C X 10 sq. mm (25mm)
4C X 16 sq. mm (28mm)
4C X 25 sq. mm (28mm)
3½ C X 50 sq. mm (35mm)
Earthing: PIPE ELECTRODE EARTHING STATIONS Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/cock and salt as required.
Earthing Conductors Supplying, straightening, shaping, laying under ground / laying on a cable tray / laying in cement concrete trench the following sizes of copper/hot dipped galvanized iron conductor. The work is inclusive of providing clamping with the trays / on the sides of the trenches, making joints whereever required and providing the hardwares and the terminating the hardwares and the termination to the equipment / earthing station / etc. Copper Conductors
No. 10 SWG Cu
No. 8 SWG Cu
PUBLIC CONVENIENCE PACKAGE 1 - ELECTRIFICATION WORKS SUB HEAD-I (INTERNAL ELECTRICAL INSTALLATIONS & WIRING) Point wiring in PVC conduit with modular type switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Group control point wiring in PVC conduit : Wiring for group controlled (looped) light point/fan point/exhaustfan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Medium class pvc conduit conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing type 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch, connection, painting etc.as required. (For raw power outlets)
Supplying and fixing of following sizes of medium gauge PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
SF SP /TP MCB DB's & VDB's Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way, Double door (ups db)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6- 32A Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, Two pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
INTERNAL LIGHT FITTINGS AND FANS: Supply, installation, testing and commissioning of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.
6 W down light Recess (Toilet)
Supplying Installation,testing & commissioning of 100mm sweep (White) ceiling Exhaust fan
Earthing PIPE ELECTRODE EARTHING STATIONS: Earthing with G.I. earth pipe 4.5 meter long,40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/cock and salt as required.
EARTHING CONDUCTORS : Supplying, straightening, shaping, laying under ground / laying on a cable tray / laying in cement concrete trench the following sizes of copper/hot dipped galvanized iron conductor. The work is inclusive of providing clamping with the trays / on the sides of the trenches, making joints whereever required and providing the hardwares and the terminating the hardwares and the termination to the equipment / earthing station / etc.
COPPER CONDUCTORS No. 10 6 SWG Cu
arcoma
B.SUBRAMONIAM AND COMPANY
RP PROJECTS PRIVATE LIMITED
M K KAVITHA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .