| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹18.0 L | L1 | Accepted-AOC DUE TO L1 |
| 2 | L2₹18.9 L+₹91,590 (5.10%)Rejected-AOC VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | ₹18.9 L+₹91,590 (5.10%) | L2 | Rejected-AOC DUE TO L2 |
| 3 | L3₹19.6 L+₹1.6 L (8.79%)Rejected-AOC | ₹19.6 L+₹1.6 L (8.79%) | L3 | Rejected-AOC DUE TO L3 |
| 4 | L4₹19.6 L+₹1.6 L (9.16%)Rejected-AOC NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | ₹19.6 L+₹1.6 L (9.16%) | L4 | Rejected-AOC DUE TO L4 |
| 5 | L5₹20.0 L+₹2.0 L (11.1%)Rejected-AOC | ₹20.0 L+₹2.0 L (11.1%) | L5 | Rejected-AOC DUE TO L5 |
Tender Value
₹24.3 L
EMD Value
₹48,500
Closing Date
5 Nov 2020, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
SPECIAL REPAIRS TO BLDG No 46 AND 53 AT BAKLOH CANTT
2020_MES_378632_1
CWE/Y-89/2020-21
Open Tender
Civil Works
Item Rate
180 days
BAKLOH CANTT DALHOUSIE
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE (I) DALHOUSIE
₹48,500
29 Jan 2021
6 Oct 2020
6 Nov 2020
6 Oct 2020
5 Nov 2020
21 Oct 2020
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Taking down chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. .
Dismantling timber in scantling 40 sqcm and over in section framed work complete all as specified and directed.
Demolition of wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
PCC 1:5:10 (nominal mix) type E-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in surface channel and drains complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork where required complete all as specified and directed.
RCC 1:1.5:3 (nominal mix) type A-1 (using 20 mm graded crushed stone aggregates ) as in slab and like complete all as specified and directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
Walling of random rubble stone masonry brought upto course well bonded bedded and soilidly hearted built in CM 1:6, complete all as specified and directed.
All as per srl item no 15 above but except stone.
PCC M-10 (nominal mix), type C-1 using 20mm graded crushed stone aggregate as in precast bond stones, set in cement mortar 1:6, complete all as specified & directed.
Steel clip-in false ceiling system with steel plain, perforated, beveled edged tile (600mmx600mm) manufactured out of 0.50 mm thick polyster coil coated galvanised steel having 180 grams zinc coating. Coil coated steel tile shall have 20 micron polyster coated finish on front side and back coat of 5 micron alkalys primer. Two sides of each tile shall be raised and piped and stopped to ensure positive engagement into the spring clip-in profile allowing for demounting of individual tiles. The rigid suspension system consists of rows of galvanized steel 0.50 mm thick clip-in profile of size 38mm x 20 mm and installed at 600 mm c/c spacing to support the tiles. Wall suspension angle, clip-in profiles shall be suspended and jointed fs of size 24 mm X 24 mmX 0.40mm thick are suspended from roof structure by GI ceiling brackets. wall suspension angles of size 24mmx24mm and 0.40mm thick are suspended from the roof structure by GI ceiling brackets. Wall suspension angle are made of coil coated steel matching the colour of tile. They are jointed to the clip in-profile system by hold on clamps. The tiles/ planks are held in place by pressure clips as per manufacuters instructions for spacing. In the flexible system the hanger and butterfly clip replace the suspension angle including necessary scaffolding all as per manufacuters specifications/instructions and specified and directd by Engr-in-charge/GE.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws all as specified.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 410-0 or Fe 310-0, complete all as specified.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
75mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. .
75 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregates) as in path etc ; surface finished even and smooth without using extra cement complete all as specified and directed.
Glass dividing strips 3 mm thick and width 38 mm inserted in position to conform to design complete all as specified and directed .
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Cutting, rubbing/grinding & mirror finish ,rounding of edges of marble/ kota stone/ granite stone complete all as specified and directed.
25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including 15 mm thick screed base in cement mortar 1:6 over and complete all as specified and directed.
Rendering cement plaster 20mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (15mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry surfaces, mixed with water proofing admixture as per manufacturer's instructions, trowelled to even and smooth finish without using extra cement complete all as specified. (Note:- WPC will be measured and paid separately)
Rendering cement plaster 20mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on other than fair faces of brick wall or on stone masonry surfaces, mixed with water proofing admixture as per manufacturer's instructions, trowelled to even and smooth finish without using extra cement complete all as specified. (Note:- WPC will be measured and paid separately)
Extra over stone walling of granite, trap or basalt stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 40mm, complete all as specified & directed.
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of wooden surfaces of any description and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over and including 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Preparation of old surfaces of wall by washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of oil bound distemper complete all as specified and directed.
Preparation of new plastered surfaces or un plastered, previously undecorated wall surfaces and applying two coats of cement base paint, complete all as specified and directed.
Preparation of plastered or un-plastered, old surfaces of walls and applying one coat of cement base paint, complete all as specified and directed.
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC concealed (concealed wiring) conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marking, medium grade, ISI marked with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring, cutting chases, making good in cement mortar in CM (1:3), finishing surfaces to match with existing and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly for modular fitting, modular box sunk for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete all as specified and directed.
All as per serial item No '41' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '41' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No. '41' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
All as per serial item No. '41' above but for 3 pin 15 Amps socket out let independent with 4 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Switch piano flush type, single pole, one way, 15 Amps, all as specified.
Socket outlet two & three pin 5 Amp flush type, all as specified.
Socket outlet two and three pin, 5 Pin, 5/16 Amp flush type controlled by one switch, all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings , all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
LED lamps, 10 watts all as specified and directed. Make:- CAT Part No LHLDERUEML8X010 of make "Havells" or equivalent in makes mentioned in Appendix "C".
S&F in replacement 2'x2' Recess/Surface mounting slimness (9 mm thin) in class LED Ceiling Panels white LED Luminaries white powder coated sheet housing LED front frame blends seamlessly with Ceiling layout of capacity 36 watt (2x2) LED extruded alluminium heat sink projected in false celing, with complete accessorized internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete. Make:Crompton cat part No- LCPL-36-CDL(2x2) or equivalent in Bajaj / Havells / Philips/ Wipro/GE.
Renewal of wall mounted LED integrating batten fitting T5, 20 Watt LED, 4 feet, PVC extruded with 20 watt LED tube rod with all acessoreis prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Havell's Cat Part No. LHEBTP7UN1W018/ C&S cat pART nO LTTB4F20WLEDP/W/ Philips CAT Part No BN021LED20S-6500 NW PSU GR or equivalent in makes mentioned in Appx 'C'.
Renewal of DBOX for MCB protected socket, of rating 25 Amps including taking down existing complete, all as specified. Make : Havells Cat Part No. DHDDCDP025202503 or equivalent in makes mentioned in Appx 'C'.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified. Make : Havells Cat Part No. DHDPSHODPW08/ C&S Cat Part No CSDBSPNSD08 or equivalent in makes mentioned in Appx 'C'.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified. Make : Havells Cat Part No. DHDPSHODPW04/ C&S Cat Part No CSDBSPNSD04 or equivalent in makes mentioned in Appx 'C'.
Renewal of sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).
MCB SPN 6 to 32 Amp, 240 Volts, 10 KA all as specified.
MCB SP 6 to 40 Amp, 240 Volts, 10 KA all as specified.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 16 sqmm, 2 core and taking down, complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25x 4mm dia (as earth lead), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Air termination, single pointed aluminium rod 12mm dia and 300mm long, fixed in repair complete all as specified and directed.
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground , fixed in repair complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, fixed in repair complete all as specified and directed.
Havish Construction
M/s Joginder Paul Bhatia
m/S Varun Gupta
kaushal builders
M/s. Rishav Sood
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .