| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-AOC A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | ₹7.8 Cr Quoted ₹8.7 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹8.7 Cr+₹1.9 L (0.22%)Rejected-AOC 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹8.7 Cr+₹1.9 L (0.22%) | L2 | Rejected-AOC Reject |
| 3 | L3₹8.7 Cr+₹2.8 L (0.32%)Rejected-AOC | ₹8.7 Cr+₹2.8 L (0.32%) | L3 | Rejected-AOC Reject |
| 4 | L4₹8.7 Cr+₹4.3 L (0.50%)Rejected-AOC 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | ₹8.7 Cr+₹4.3 L (0.50%) | L4 | Rejected-AOC Reject |
| 5 | L5₹8.7 Cr+₹6.8 L (0.78%)Rejected-AOC 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | ₹8.7 Cr+₹6.8 L (0.78%) | L5 | Rejected-AOC Reject |
Tender Value
₹7.1 Cr
EMD Value
₹14.2 L
Closing Date
23 Jan 2023, 1:00 pmClosed
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Executive Engineer M/Garh W.S. Mech. Divn., Narnaul, 123001
Replacement of 30 Cs to 50 Cs VT Axial Flow Pumps with connected electric equipments at Pump Houses SF-1 to SF-6 of Satnali Feeder in W.S. Mech. Division Narnaul.
2022_HRY_251958_2
4980-95/9-A dated 27/12/2022
Open Tender
Pumps/Motors
Works
240 days
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
₹14.2 L
Yes
NARNAUL
14 Jul 2023
30 Dec 2022
24 Jan 2023
30 Dec 2022
23 Jan 2023
30 Dec 2022
11 Jan 2023
Amount
Replacement of 50 Cs existing V.T. axial flow pump of lift height 23.02' with RPM 745, including MS Delivery pipe with all flanges, Y-Body, bend, syphon breaker valve & support of bend with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (2 No. at SF-6)
Replacement of 35 Cs existing V.T. axial flow pump of lift height 18.50’ with RPM 980, including MS Delivery pipe with all flanges, Y-Body, bend, syphon breaker valve with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (1 No. at SF-5)
Replacement of 30 Cs existing V.T. axial flow pump of lift height 29.5’ with RPM 980, including MS Delivery pipe with all flanges, Y-Body, bend, syphon breaker valve with any other leftover item duly painted inner and outer side as per site requirement & as per approved technical specification (Annexure-A,D,F) (1 No. at SF-1 & 2 Nos. at SF-2)
Supply, Erection and commissioning of induction motors solid shaft of 225 HP suitable for 50 Cs VT axial flow pumps, 168 KW, 745 RPM, 8 Pole, 415 voltage, 3 phase, 50 Hz as per approved technical specification (Annexure-B,D,F) and site requirements. (3 No. at SF-6)
Supply, Erection and commissioning of induction motors solid shaft of 170 HP suitable for 30 Cs VT axial flow pumps, 128 KW, 980 RPM, 6 Pole, 415 voltage, 3 phase, 50 Hz as per approved technical specification (Annexure-B,D,F) and site requirements. (5 No. at SF-1, 6 Nos. at SF-2, 5 No. at SF-3 & 5 No. at SF-4 )
Supply, Erection and commissioning of induction motors solid shaft of 150 HP suitable for 35 Cs VT axial flow pumps, 112 KW, 980 RPM, 6 Pole, 415 voltage, 3 phase, 50 Hz as per approved technical specification (Annexure-B,D,F) and site requirements.(4 No. at SF-5)
Supply, Erection & Commissioning of ATS Starter suitable for 170 HP motoras per approved technical specification. (01 Nos for SF-4) (Annexure-C,D,F)
Replacement with Supply, Erection & Commissioning of Auto Tranformer for 150 HP in existing Starter Panel (ATS Type) Air cooled/immersed with different taps provided to start the motor at, say, 50%, 65% or 80% of line voltage of 415 Volt as per site requirement & as per approved technical specification. {150 HP - 03 Nos at SF-5} (Annexure-C,D,F)
Replacement with Supply, Erection & Commissioning of Auto Tranformer for 170 HP in existing Starter Panel (ATS Type) Air cooled/immersed with different taps provided to start the motor at, say, 50%, 65% or 80% of line voltage of 415 Volt as per site requirement & as per approved technical specification. {170 HP - 16 Nos. (04 Nos at SF-1, 05 No. at SF-2, 04 No at SF-3 & 03 No. at SF-4)} (Annexure-C,D,F)
Replacement with Supply, Erection & Commissioning of Auto Tranformer for 225 HP in existing Starter Panel (ATS Type) Air cooled/immersed with different taps provided to start the motor at, say, 50%, 65% or 80% of line voltage of 415 Volt as per site requirement & as per approved technical specification. {225 HP - 01 No. at SF-6}. (Annexure-C,D,F)
Providing and commissioning of LTDB of Capacity 1600 Amps including all accessories as ACB,1600 Amps -01 No incomer,MCCB 630 Amps-05 nos outgoing & MCCB 160 Amp. - 01 No. outgoing , 63Amp MCB for lighting loads, indicators,relays,meters,push buttons,bus bars etc complete suitable for operation of 05 nos Motors of capacity 225 HP & 01 No. 50 HP as per approved technical specification (01 No at SF-6) (Annexure-C) alongwith Supply , Erection & Commissioning of Capacitor Bank 90 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. ( 05 No. at SF-6) Supply , Erection & Commissioning of Capacitor Bank 65 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. (8 No. each at SF-1 to 4) Supply , Erection & Commissioning of Capacitor Bank 50 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. (07 No. at SF-5) Supply , Erection & Commissioning of Capacitor Bank 20 KVAR to connected for each starter panels as per site requirement & as per approved technical specification. (01 No. at SF-6) (Annexure-C,D,F)
S/E/C of MS Component duly dual painting as a) Outer Jaal Made of 40x40x6mm MS Angle and 35x6 MS Flat for 16X2 Sq mtr b) Internal Jaal Made of 40x40x5mm MS Angle and 35x6 MS Flat for 16X13.2 Sq mtr c) Trash Rack Made up of 75x40mm Channel, and 75X8mm Flat d) Open Rack made up of 40x40x5mm Angle, 35x6mm Flat. e) Safety grills made up of 40x40x5 mm angle, 35x6 mm Flat as per approved make : Jindal/Sail/TATA
M/s KRP Engineering Pvt. Ltd.
Sahil Engg. Works
Avon Engineering Company
ace marketing pvt ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .